ASSEMBLY (see page 04)
FAULT CAUSE REMEDY
⁄ Insufficient water ⁄ Supply pressure inadequate ⁄ Check water pressure (If a pump has been installed check
to see if the pump is working).
⁄ Regulator filter dirty ⁄ Clean filter in front of the mixer and on the MTC-thermo
cartridge
⁄ filter insert shower dirty ⁄ Clean filter insert between shower and hose
⁄ Crossflow, hot water being forced into cold water pipe, or
vice versa, when mixer is closed
⁄ Backflow preventers dirty or leaking ⁄ Clean backflow preventers, exchange if necessary
⁄ Spout temperature does not correspond with temperature
set
⁄ Thermostat has not been adjusted ⁄ Adjust thermostat
⁄ Hot water temperature too low ⁄ Increase hot water temperature to 42 ºC to 65 ºC
⁄ Temperature regulation not possible ⁄ thermo cartridge calcified ⁄ Exchange thermo cartridge
⁄ Instantaneous heater didn't work with thermostat ⁄ Filters are dirty ⁄ Clean the filter ⁄ exchange filter
⁄ check valve hasn't moved back ⁄ Exchange check valves
⁄ Flow limiter in handshower isn’t removed ⁄ Remove flow limiter
SPECIAL ACCESSORIES (order as an extra)
tile-matching-disk #95239000 (see page 13)
SPARE PARTS (see page 13)
FLOW DIAGRAM (see page 08)
overhead shower
Hand shower
DIMENSIONS (see page 08)
CLEANING (see page 10)
OPERATION (see page 09)
To empty the overhead shower after use, hold it in a slightly inclined position.
MAINTENANCE (see page 12)
⁄ The mixer is equipped with check valves. The check valves must be
checked regularly according to DIN EN 1717 in accordance with na-
tional or regional regulations (at least once a year).
⁄ To guarantee the smooth running of the thermostat, it is necessary from
time to time to turn the thermostat from total hot to total cold.
ADJUSTMENT (see page 07)
After the installation, the output temperature of the thermostat must be
checked. A correction is necessary if the temperature measured at the output
differs from the temperature set on the thermostat.
SAFETY FUNCTION (see page 07)
The desired maximum temperature for example max. 42º C can be pre-set
thanks to the safety function.
Do not use silicone containing acetic acid!
SYMBOL DESCRIPTION
SAFETY NOTES
Gloves should be worn during installation to prevent crushing and cutting injuries.
The product may only be used for bathing, hygienic and body cleaning purposes.
The arm of the shower head is intended only to hold the shower head. Do not load
it down with other objects!
Children as well as adults with physical, mental and ⁄or sensoric impairments must
not use this product without proper supervision. Persons under the influence of
alcohol or drugs are prohibited from using this product.
Do not allow the streams of the shower touch sensitive body parts (such as your
eyes). An adequate distance must be kept between the shower and you.
The product may not be used as a holding handle. A separate handle must be
installed.
The hot and cold supplies must be of equal pressures.
INSTALLATION INSTRUCTIONS
⁄ Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
⁄ The pipes and the fixture must be installed, flushed and tested as per the applicable
standards.
⁄ The plumbing codes applicable in the respective countries must be observed.
⁄ The installation dimensions stated in these installation instructions are ideal for
people of approximately 1700 mm in body height. The dimensions can be altered
if required. In this case, pay attention to the fact that a change of installation height
will also change the minimum height, and that the altered mounting dimensions must
be taken into consideration.
⁄ During installation of the product by qualified trained personnel, make sure that the
entire fastening surface is even and smooth (no protruding seams or tile offset), that
the finish of the wall is suitable to apply the product and has no weak points.
⁄ The premounted filter insert must be used to ensure a normal flow of the shower and
to prevent dirt from entering through the pipes. Dirt entering can affect the function
and ⁄or lead to damages to the shower. Hansgrohe will not be held liable for this
type of damage.
⁄ The product is not designed to be used with steam baths!
⁄ If required, the bottom part of the pipe between the fixture and the shower head
can be shortened with a fine-toothed saw.
⁄ If the continuous water heater causes any problems, or you have different
water pressures you must install a water limiter to the cold supply, (ordered
separately,article number 97510000).
TECHNICAL DATA
Operating pressure: max. 1 MPa
Recommended operating pressure: 0,16 - 0,5 MPa
Test pressure: 1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature: max. 70°C
Recommended hot water temp.: 65°C
Centre distance: 150±12mm
Connections R 1⁄2: cold right - hot left
Thermal disinfection: max. 70°C ⁄ 4 min
⁄ Safety against backflow
⁄ The product is exclusively designed for drinking water!
EN