manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. B.E.G.
  6. •
  7. Security Sensor
  8. •
  9. B.E.G. RC-plus next 130 Service manual

B.E.G. RC-plus next 130 Service manual

2
1:4
1.
0.5
0.25
Futura Book 24Pt
1
LUXOMAT®RC-plus next
1:4
1.
0.5
0.25
Futura Book 24Pt
1:4
1.
0.5
0.25
Futura Book 24Pt
1:4
1.
0.5
0.25
Futura Book 24Pt
1
2
3
1
3
2
4
TEST
16
12
84
15s 30s
1
1,5 2 3 5 6 7 10
+-
12
1:4
1.
0.5
0.25
Futura Book 24Pt
180°
10°
1
2
45° 1
2
max min
12
3
1:4
1.
0.5
0.25
Futura Book 24Pt
> 1m
4
1 2
2.5m
21m
8m
3m 1m
2.5m
21m
8m
1m
2.5m
21m
8m
1m3m
21m
8m
1m 3m
21m
21m
21m
21m
8m
1m 3m
21m
8m
1m 3m
2.5m
21m
8m
3m 1m
2.5m
21m
8m
1m
2.5m
21m
8m
1m3m
21m
8m
1m 3m
21m
21m
21m
21m
8m
1m 3m
21m
8m
1m 3m
2
3
1
2.5m
21m
8m
3m 1m
2.5m
21m
8m
1m
2.5m
21m
8m
1m3m
21m
8m
1m 3m
21m
21m
21m
21m
8m
1m 3m
21m
8m
1m 3m
130° 230° 280°
1:4
1.
0.5
0.25
Futura Book 24Pt
4
11
10
78 9
5
32
1) Push in cover-up clips on marked place
(blind out distant range/close-up range/
both)
2) Cover-up stickers
Operating and mounting instructions for motion detector LUXOMAT®RC-plus next
1) Caution: have all work involving the 230V
mains supply carried out by a qualified
electrician! Before starting disconnect the
mains! Please be aware, that the LUXOMAT®
RC-plus next is not suitable as an intrusion
detector, since it is not equipped with a
tamper contact.
2) Socket base corner mounting
3) In the case of mounting over the previous
socket “RC-plus” use the extra cover that is
provided.
1) Wall mounting
2) Ceiling mounting
3) Outside corner mountable with plug-in
socket (included with the RC-plus next 280,
see point 20)
1) Connection cable from top down
2) Connection cable from below
3) Connection cable from behind
4) Terminal markings
(Wiring diagrams see point 17)
1) Press here for separation of terminal case
and plug-in socket
2) Mount the plug-in socket with two screws
and the enclosed seal rings on a firm base
(Pay attention to inserting of the connection
cable, see point 4)
3) Imprint the terminal case on plug-in socket.
The terminal case on the plug-in socket is
rotatable upto 10° for fine adjustment of the
motion detector.
Mechanical range adjustment
+: e.g. 21m, –: e.g. 5m (mounting height 2.50 m)
mounting height min. = 2.00m
(RC-plus next 130: 1 zone; RC-plus next 230:
2 zones; RC-plus next 280: 3 zones, see point 8)
Follow-up time
Test operation, 15 sec. ... 16 min., Pulse operation
(Test operation: range testing, detector switches
on/off the lighting at any recognized movement)
Lux value
Night operation...Dusk...Day operation
(Day operation: light sensor inactive, switching at
any brightness value)
On delivery the potentiometers are adjusted in
position “TEST” and “SUN” symbol (daytime
operation). With this adjustments the following
regular values are active:
Follow-up accommodation: 3min.
Lux value: approx. 20Lux
Reset: The adjusting into “Factory settings” from
any other position causes a “Reset” of the device.
That means all parameters are resetted into factory
settings (fast LED-flashing).
LED Functional display
Display of movements and operating states
(Switchable with remote control LUXOMAT®IR-RC,
see point 11)
1) If possible mount unit on a safe place
(wall or ceiling mount).
2) Influence of weather reduces the lifetime of
the unit. Please take care to mount correctly.
3) Minimum distance to switched lighting,
frontally or laterally to device: 1m
4) Never mount the connected lights below the
motion detector!
1) LUXOMAT®IR-RC (accessory, see point 20)
2) LUXOMAT®IR-RC-Mini (accessory, see
point 20)
Caution: Settings with remote control subscribe
the settings by courtesy of potentiometers (see
point 5 ) (for description see point 12).
1) Remove the coverring with slightly pressure
2) Adjust Range, follow-up accommodation and Lux value with screwdriver
1) Range walking across: approx. 21m
2) Range walking towards: approx. 7 - 8m
3) Anti-creep: approx. 1 - 3m
1) Change range or sensitivity adjustments
by swivelling of the sensor head vertically
or horizontally (Sensor head horizontally =
max. range)
2) Fine adjustment of sensor axis
Mechanical range adjustment possible
for every zone separately (see point 5)
Self test cycle
After mounting and connecting the 230 VAC supply
voltage, the LED flashed for 1min. to show a self testing
unit. Then the unit is ready for operation and the set-
tings can be made manually or with remote control
(see point 11).
6
&“TEST”
TEST
16
12
84
15s 30s
1
1,5 2 3 5 6 7 10
3
GB
1. Mounting preparations 2. Mounting types
4. Inserting of the connection cable
3. Plug-in socket
5. Putting into operation / Settings
9. Exclude sources of interference
8. Sensitivity adjustment (mounting height 2.50m);
mounting height min. = 2.00m
(Sensor head justified horizontally, see point 7)
7. Sensor head optics
6. Factory settings
10. Mounting place 11. Settings of remote control
32
1
10°
Test operation
Switches the light ON/OFF when
movement is detected.
Unlocking device
Lux value: Day operation
light sensor inactive, switching
at any brightness value
Lux value: approx. 100Lux
Onset of dusk
Lux value: approx. 25 Lux
Advanced dusk
Lux value: approx. 2 Lux
Darkness
Automatic reading in the
current light value
Individual light value
2 - 2500 Lux
Impulsfunction1)
1sec. ON, 9 sec. OFF
Follow-up time
15 sec. upto 16 min.
Vacation- and comfort function
Switching ON/OFF
On: By achieving the Lux value
1 hour daylight independent
of mouvements, then normal
operation (switching time
changeable, see point 15)
Alarm function
Switching ON/OFF,
(ON for 30sec., OFF for
1sec., then normal operation)
Walk test
Switching ON/OFF
Anti-creep protection
Switching ON/OFF
Sensitivity adjustment
~ +15 %, ~ –30 %
Light OFF
Switches the light ON again when
movement is detected.
Reset
Erasing of all of the values set
using the remote control.
(Then potentiometer-settings
activ, see point 5.)
Light ON for 12 h / Light OFF for 12 h
By pressing once the party button, the
light is switched on for a period of 12
hours. By pressing the party button
twice, the light remains switche off until
the next evening (see point 14).
Double Locking (sabotage protection)
Locking of IR-RC-reception. After lock-
ing the device press “Locking” again
during a period of 5 sec. (reset see
point 6)
Reset
Light OFF, then automatic mode
Light ON for 12 h / Light OFF for 12 h
By pressing once the party button, the
light is switched on for a period of 12
hours. By pressing the party button
twice, the light remains switched off
until the next evening (see point 14).
Power supply: 230 V~ +6 % -10 %
Rated capacity: 16 A relay
Switching power:
3000W (13 A, 250 V, cos(ϕ)= 1)
1500 VA (6.5 A, 250 V, cos(ϕ)= 0.5)
Range: approx. 20m
Time settings: Impuls, 15 sec. - 16 min.
Follow-up accommodation: active with factory
settings and with programming of remote con-
trol LUXOMAT®IR-RC (15 sec. - 16 min.)
Photo electric switch: approx. 2 - 2500Lux
Factory settings: follow-up accommodation
3 min., photo electric switch approx. 20Lux
Detection area: 130° / 230° / 280°,
360° anti-creep protection
Degree of protection/class: IP54 / II
Dimensions: L 121 x W 71 x H 85 mm
Material: UV-stabilised Polycarbonate
Colours: white / black / brown / silver (only
RC-plus next 230)
Mounting types: wall and ceiling mounting, RC-
plus next 280: outside corner mountable with
inclused plug-in socket
Inserting of the connection cable: once or twice
from top down, from below and from behind
Range adjustment:
> selective mechanical adjustment for every
zone in the 130°, 230° and 280° unit
> swivelling of the sensor head: vertically –10
upto +45°, horizontally + – 90°, laterally ±10°
> electronic +15 % up to 30 % with remote
control LUXOMAT®IR-RC
> With blank out clips (included)
Electrical adjustments: in traditional manner
with potentiometers valid for time and Lux value
only, with infrared remote control.
LED-Display: one LED per detection zone
Lock device
Reset
Light OFF, then automatic mode
Caution: The infrared receiver of the
RC-plus next is positioned in the anti-
creep protection. For best reception
target anti-creep with remote control.
Because of the sabotage protection the function
“Light off” is deactivated in the factory. When
required it must be activated again:
1. Mains to be disconnected
2. Mains to be connected - a self test cycle
of 60sec. starts (the LED is flashing, see
point 5).
3.
Activation/deactivation of the function “Light
Off” can be done only during the self testing
cycle
For a
ctivation of the function “Light OFF”
the button “Light OFF” must be pressed
during the self testing cycle (the LED will
flash quickly).
For deactivation “Light OFF” the button
“Reset” must be pressed during the self
testing cycle (the LED will flash slowly).
Caution: The implementation of “Reset” with po-
tentiometers (see point 6) or with remote control
(see point 12) does not influence the activation/
deactivation of the function “Light OFF”
The energy saving and comfort by courtesy of
follow-up accommodation of the motion detector
RC-plus next is unique. That means: If the last
detected movement is located in the anti-creep
zone (for instance mounting over a doorway),
the follow-up accomodation will be reduced to
1/4 of the original time = energy saving.
f.ex.: adjusted follow-up accommodation = 16 min.
a) Walking towards unit: effective follow-up
accommodation = 4min.
b) Removing from unit: effective follow-up
accommodation = 16 min.
Caution: The “dynamic follow-up accommoda-
tion“ will be activeted or deactivated on follow-
ing conditions:
Follow-up accommodation “active”:
> Unit is located in “factory settings“
(see point 6)
> Settings of follow-up accommodation with
remote control values 15 sec. - 16 min.
(see point 12)
Follow-up accommodation “inactive”:
> Settings of follow-up accommodation with
potentiometers values 15 sec. - 16 min.
(see point 5)
1) As soon as the function “Chime/Impulse”
is activated, the following functions will
be blocked: Alarm function, Light ON for
12 hrs / Light OFF for 12 hrs, Vacation- and
comfort function
The duration of the on-period can be adjusted:
1. “Unlock” unit with remote control
2. The button “Co“ to be operated. The LED
flashes for 10sec.
3. During these 10 seconds the duration of the
light-on period can be selected: from e.g.
15 sec. = 15 min. up to 16 min. = 16 hrs
4. The unit to be locked with the button “Lock”.
5. “Vacancy/Comfort” is activ now (deactivati-
on see point 12)
Caution: If the “Vacation- and comfort function”
is active or with lower deviation of the Lux value
the RC-plus next turns on the light again after a
time delay of 60 sec. LUXOMAT®Motion detector:
RC-plus next 130 white: 97001
brown: 97011
black: 97021
RC-plus next 230 white: 97002
brown: 97012
black: 97022
silver: 97042
RC-plus next 280 white: 97003
brown: 97013
black: 97023
LUXOMAT®Remote control:
IR-RC (incl. wall bracket) 92000
IR-RC-Mini 92090
LUXOMAT®Socket base for corner mounting:
RC-plus next ES white: 97004
RC-plus next ES brown: 97014
RC-plus next ES black: 97024
RC-plus next ES silver: 97043
(With LUXOMAT®RC-plus next 280 included)
Accessory:
Arc extinction kit 10880
Wall bracket for IR-RC as replacement 92100
Standard operation
(with optional arc extinctions kit)
Optional extension for switching of parallel
inductors, rocker switches, fluorescent lamps etc.
LN L’ RC
Terminal connection for parallel operation
We recommend max. 5 motion detectors.
LN L’ LN L’
Permanent light operation with external push
button
Additionally manuel switching is possible. The
NC-contact is to press for approx. 0.5 - 2sec.
LN L’
Permanent light operation with external switch
Switching is manually possible (permanent light
operation). Caution: Light has to switched off
manually.
LN L’
MAN 5517 – 091209-3
B
.
E
.
G
.
120
120
70
7070
63
63
46
63
57 27
57 27
RC-plus next 230°
RC-plus next
B
.
E
.
G
.
120
120
70
7070
63
63
46
63
57 27
57 27
RC-plus next 230°
RC-plus next
12. Functions of LUXOMAT®IR-RC 19. Technical data
17. Wiring diagrams
14. Activation “Light OFF”
13. Functions of LUXOMAT®
IR-RC-Mini
18. Dimensions (mm)
15. Vacation- and comfort function
16. Follow-up time savings
20. Article / Part nr. / Accessory

This manual suits for next models

12

Other B.E.G. Security Sensor manuals

B.E.G. LUXOMAT LC-Click 140 Owner's manual

B.E.G.

B.E.G. LUXOMAT LC-Click 140 Owner's manual

B.E.G. LUXOMAT PD4-M-DALI/DSI-1C/PD4-S User guide

B.E.G.

B.E.G. LUXOMAT PD4-M-DALI/DSI-1C/PD4-S User guide

B.E.G. LUXOMAT PD4-M-GH-SM User guide

B.E.G.

B.E.G. LUXOMAT PD4-M-GH-SM User guide

B.E.G. LUXOMAT PICO-N-M-1C-FC User guide

B.E.G.

B.E.G. LUXOMAT PICO-N-M-1C-FC User guide

B.E.G. LUXOMAT net PD11-KNX-FLAT-BA User manual

B.E.G.

B.E.G. LUXOMAT net PD11-KNX-FLAT-BA User manual

B.E.G. LUXOMAT PD2-M-2C User manual

B.E.G.

B.E.G. LUXOMAT PD2-M-2C User manual

B.E.G. LUXOMAT PD4-S-DAA4G User guide

B.E.G.

B.E.G. LUXOMAT PD4-S-DAA4G User guide

B.E.G. LUXOMAT net PD4-M-DAA4G User guide

B.E.G.

B.E.G. LUXOMAT net PD4-M-DAA4G User guide

B.E.G. LUXOMAT PD4-M-2C-DS User guide

B.E.G.

B.E.G. LUXOMAT PD4-M-2C-DS User guide

B.E.G. 93386 User manual

B.E.G.

B.E.G. 93386 User manual

B.E.G. LUXOMAT PD2-M-DALI/DSI-SM/FC User guide

B.E.G.

B.E.G. LUXOMAT PD2-M-DALI/DSI-SM/FC User guide

B.E.G. LUXOMAT PD9-M-2C User guide

B.E.G.

B.E.G. LUXOMAT PD9-M-2C User guide

B.E.G. LUXOMAT Indoor 180/R-2W UK Service manual

B.E.G.

B.E.G. LUXOMAT Indoor 180/R-2W UK Service manual

B.E.G. LUXOMAT BL2 User manual

B.E.G.

B.E.G. LUXOMAT BL2 User manual

B.E.G. Luxomat PD2-S User manual

B.E.G.

B.E.G. Luxomat PD2-S User manual

B.E.G. LUXOMAT net PD11-KNX-FLAT-ST User manual

B.E.G.

B.E.G. LUXOMAT net PD11-KNX-FLAT-ST User manual

B.E.G. LUXOMAT PD9-S User manual

B.E.G.

B.E.G. LUXOMAT PD9-S User manual

B.E.G. LUXOMAT PD4-M-1C-SM User guide

B.E.G.

B.E.G. LUXOMAT PD4-M-1C-SM User guide

B.E.G. LUXOMAT PD4-M-DIM-SM User guide

B.E.G.

B.E.G. LUXOMAT PD4-M-DIM-SM User guide

B.E.G. LUXOMAT PD4-S Series User manual

B.E.G.

B.E.G. LUXOMAT PD4-S Series User manual

B.E.G. LUXOMAT LC-Mini 120 Owner's manual

B.E.G.

B.E.G. LUXOMAT LC-Mini 120 Owner's manual

B.E.G. LUXOMAT PD4-S Series User guide

B.E.G.

B.E.G. LUXOMAT PD4-S Series User guide

B.E.G. LUXOMAT PD5-M-1C-Clip User guide

B.E.G.

B.E.G. LUXOMAT PD5-M-1C-Clip User guide

B.E.G. LUXOMAT PD4-M-1C-C-SM User guide

B.E.G.

B.E.G. LUXOMAT PD4-M-1C-C-SM User guide

Popular Security Sensor manuals by other brands

Sekotech OPTIC-2 manual

Sekotech

Sekotech OPTIC-2 manual

Lince 1964-SAXA-A Installation, operation and maintenance manual

Lince

Lince 1964-SAXA-A Installation, operation and maintenance manual

AJAX DoorProtect Plus quick start guide

AJAX

AJAX DoorProtect Plus quick start guide

netvox R718WB2 user manual

netvox

netvox R718WB2 user manual

Zublin Swiss Garde 4000 user manual

Zublin

Zublin Swiss Garde 4000 user manual

BUCKINGHAM MFG 108 Instructions & warnings

BUCKINGHAM MFG

BUCKINGHAM MFG 108 Instructions & warnings

Tractel LCR Operating and maintenance instructions

Tractel

Tractel LCR Operating and maintenance instructions

Banner PVS28 Series instruction manual

Banner

Banner PVS28 Series instruction manual

steute sWave 2.4 GHz-safe Mounting and wiring instructions

steute

steute sWave 2.4 GHz-safe Mounting and wiring instructions

Velleman PIR1300 user manual

Velleman

Velleman PIR1300 user manual

GST DI-9103E quick start guide

GST

GST DI-9103E quick start guide

Security-Center FU5120WB installation guide

Security-Center

Security-Center FU5120WB installation guide

Firefly OMNIGUARD 540 Operating and service manual

Firefly

Firefly OMNIGUARD 540 Operating and service manual

Datasensing TLU Series instruction manual

Datasensing

Datasensing TLU Series instruction manual

elobau 122 Series Translation of the original operating instructions

elobau

elobau 122 Series Translation of the original operating instructions

General NGD8800 user manual

General

General NGD8800 user manual

Wenglor P1PY1 Series operating instructions

Wenglor

Wenglor P1PY1 Series operating instructions

SafeGuard Compass user guide

SafeGuard

SafeGuard Compass user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.