1. Press to enter the TEACH-IN menu.
The sensor displays the selected output. TEACH-IN > <SETQ1>.
2. Press or to scroll through the output opons: <SETQ1>, <SETQ2>, or <ANALOG> (only for diuse models).
3. Press to select an output.
The sensor displays the current output and mode selecons.
4. Press or to scroll through Output 1 opons: Mode Q1, TEACH 1.1, TEACH 1.2, HYST 1.
The sensor displays the TEACH opons for the selected output.
5. Press to view the output mode opons.
The sensor displays an arrow to indicate that the opons can be viewed.
6. Press or to scroll through the output mode opons.
7. Press to select an output mode opon.
The sensor saves the selected output mode opon.
8. Press or to scroll through Output 1 opons: TEACH 1.1, <203>.
The sensor again displays TEACH opons for the selected output.
9. Press to select an opon: TEACH 1.1, 203.
The sensor is ready to learn Limit 1.
10. Press to teach the target condion.
The sensor saves the Limit 1 seng and returns to the Output 1 menu level.
11. Press to access Manual Adjust.
12. Press to decrease or to increase the value of each digit.
The ashing cursor indicates the digit is acve, starng with the fourth digit locaon from the le.
13. Press to select the digit and move it to the le by one digit locaon.
14. Press when the cursor ashes on the rst digit on the le and the value is correct.
The sensor saves the seng and returns to the Output 1 menu level.
15. Press to teach the Limit 1.2 from the Output 1 menu. TEACH 1.2 > <12000>.
The sensor again displays the TEACH opons for the selected output. Repeat the procedure for Limit 1.1.
16. Press to select the Hysteresis funcon.HYST 1 > <±005> .
The ashing cursor indicates that the digit is acve, starng with the fourth digit locaon from the le. The minimum factory default
seng for hysteresis is ± 005. The maximum seng for hysteresis is ± 254 mm (± 9.99 in).
17. Press to decrease and to increase the value of each digit.
18. Press to select the digit and move it to the le by one digit locaon.
19. Press when the cursor is on the rst digit on the le and the value is correct.
•HYST 1 > <±254> if the value is valid.
•HYST 1 > Limited! if the value is outside accepted limits.
The sensor saves the seng and returns to the HYST 1 menu level.
20. Press or to return to other Output 1 funcons or press Escape to move up one menu level.
The TEACH procedure for Output 1 and Output 2 is the same. If the value is outside accepted limits, the sensor does not save the new
seng.
L-GAGE®LT7 Long-Range Time-of-Flight Laser Sensor
10 www.bannerengineering.com - Tel: +1-763-544-3164 P/N 120244 Rev. C