manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. BEKA
  6. •
  7. Measuring Instrument
  8. •
  9. BEKA BA304NE User manual

BEKA BA304NE User manual

Other manuals for BA304NE

1

This manual suits for next models

1

Other BEKA Measuring Instrument manuals

BEKA BA338C User manual

BEKA

BEKA BA338C User manual

BEKA BA304G User manual

BEKA

BEKA BA304G User manual

BEKA BA554D User manual

BEKA

BEKA BA554D User manual

BEKA BA304C User manual

BEKA

BEKA BA304C User manual

BEKA FOUNDATION BA444NDF-F User manual

BEKA

BEKA FOUNDATION BA444NDF-F User manual

BEKA BA507E Installation and operating instructions

BEKA

BEKA BA507E Installation and operating instructions

BEKA BA354ND User manual

BEKA

BEKA BA354ND User manual

BEKA FOUNDATION BA644DF-F User manual

BEKA

BEKA FOUNDATION BA644DF-F User manual

BEKA BA324ND User manual

BEKA

BEKA BA324ND User manual

BEKA BA304E User manual

BEKA

BEKA BA304E User manual

BEKA BA537E User manual

BEKA

BEKA BA537E User manual

BEKA BA558C User manual

BEKA

BEKA BA558C User manual

BEKA BA374NG User manual

BEKA

BEKA BA374NG User manual

BEKA FOUNDATION BA444DF-F User manual

BEKA

BEKA FOUNDATION BA444DF-F User manual

BEKA BR323AL User manual

BEKA

BEKA BR323AL User manual

BEKA A504G-SS-PM User manual

BEKA

BEKA A504G-SS-PM User manual

BEKA Advisor A70 User manual

BEKA

BEKA Advisor A70 User manual

BEKA BA307E User manual

BEKA

BEKA BA307E User manual

BEKA BA304NE User manual

BEKA

BEKA BA304NE User manual

BEKA BA317NE User manual

BEKA

BEKA BA317NE User manual

BEKA BA514G User manual

BEKA

BEKA BA514G User manual

BEKA BA448CF-F User manual

BEKA

BEKA BA448CF-F User manual

BEKA BA307SE User manual

BEKA

BEKA BA307SE User manual

BEKA BA526C User manual

BEKA

BEKA BA526C User manual

Popular Measuring Instrument manuals by other brands

Powerfix Profi 278296 Operation and safety notes

Powerfix Profi

Powerfix Profi 278296 Operation and safety notes

Test Equipment Depot GVT-427B user manual

Test Equipment Depot

Test Equipment Depot GVT-427B user manual

Fieldpiece ACH Operator's manual

Fieldpiece

Fieldpiece ACH Operator's manual

FLYSURFER VIRON3 user manual

FLYSURFER

FLYSURFER VIRON3 user manual

GMW TG uni 1 operating manual

GMW

GMW TG uni 1 operating manual

Downeaster Wind & Weather Medallion Series instruction manual

Downeaster

Downeaster Wind & Weather Medallion Series instruction manual

Hanna Instruments HI96725C instruction manual

Hanna Instruments

Hanna Instruments HI96725C instruction manual

Nokeval KMR260 quick guide

Nokeval

Nokeval KMR260 quick guide

HOKUYO AUTOMATIC UBG-05LN instruction manual

HOKUYO AUTOMATIC

HOKUYO AUTOMATIC UBG-05LN instruction manual

Fluke 96000 Series Operator's manual

Fluke

Fluke 96000 Series Operator's manual

Test Products International SP565 user manual

Test Products International

Test Products International SP565 user manual

General Sleep Zmachine Insight+ DT-200 Service manual

General Sleep

General Sleep Zmachine Insight+ DT-200 Service manual

Sensa Core Lacto Spark user manual

Sensa Core

Sensa Core Lacto Spark user manual

VOLTCRAFT UTS-1980 operating instructions

VOLTCRAFT

VOLTCRAFT UTS-1980 operating instructions

EBCHQ 94915 Operation manual

EBCHQ

EBCHQ 94915 Operation manual

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Balluff

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Pulsar IMP Lite Series instruction manual

Pulsar

Pulsar IMP Lite Series instruction manual

ETCR 6800 user manual

ETCR

ETCR 6800 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

1. DESCRIPTION
The BA304NE and BA324NE are field mounting, Ex nA
and Ex tc certified digital indicators that display the current
flowing in a 4 20mA loop in engineering units. They are
loop powered but only introduce a 1.2V drop into the loop.
The two models are electrically similar, but have different
size displays.
Model Display
BA304NE 4 digits 34mm high
BA324NE 5 digits 29mm high and
31 segment bargraph.
This abbreviated instruction sheet is intended to assist with
installation and commissioning, a comprehensive
instruction manual describing safety certification, system
design and calibration is available from the BEKA sales
office or may be downloaded from our website.
Both models have ATEX and IECEx certification permitting
installation in Zone 2 flammable gas and Zone 22
combustible dust atmospheres without the need for Zener
barriers or galvanic isolators. The certification label, which
is located on the top of the instrument enclosure, shows
the certificate numbers and the certification codes. Copies
of certificates may be downloaded from our website.
All models have gas and dust certification.
2. INSTALLATION
The BA304NE and BA324NE indicators have robust IP66
glass reinforced polyester (GRP) enclosures incorporating
an armoured glass window and stainless steel fittings.
They are suitable for exterior mounting in industrial Zone 2
or Zone 22 environments.
They are surface mounting, but may be pipe mounted
using an accessory kits.
Fig 1 shows the installation procedure.
Fig 1 Installation procedure Fig 2 Dimensions and terminal connections
The indicator’s earth terminal is connected to the carbon
loaded GRP enclosure. If this enclosure is not bolted to an
earthed post or structure, the earth terminal should be
connected to the plant potential equalising conductor.
A bonding plate is provided to ensure electrical continuity
between the three conduit cable entries.
Terminals 8, 9, 10 & 11 are only fitted when the indicator
includes optional alarms. See full manual for details.
Terminals 12, 13 & 14 are only fitted when the indicator
includes an optional backlight. See full manual for details.
EMC
For specified immunity all wiring should be in screened
twisted pairs, with the screens earthed in the safe area.
Fig 3 Typical measurement loop
Units of meas rement & tag n mber
Both indicators have an escutcheon around the liquid
crystal display which can be printed with any units of
measurement and tag information specified when the
indicator was ordered. If no information is supplied a blank
escutcheon will be fitted but legends may be added on-site
via an embossed strip, dry transfer or a permanent marker.
Printed escutcheons are available from BEKA as an
accessory which should be fitted on top of the blank
escutcheon. Do not remove the blank escutcheon.
To gain access to the escutcheon remove the terminal
cover by unscrewing the two 'A' screws which will reveal
two concealed 'D' screws. If the instrument is fitted with an
external keypad, also unscrew the two 'C' screws securing
the keypad and unplug the five way connector. Finally
unscrew all four 'D' screws and carefully lift off the front of
the instrument.
3. OPERATION
The indicators are controlled and configured via four push
buttons located behind the instrument control cover, or via
an optional keypad on the outside of the control cover. In
the display mode i.e. when the indicator is displaying a
process variable, these push buttons have the following
functions:
PWhile this button is pushed the indicator will
display the input current in mA, or as a
percentage of the instrument span depending
upon how the indicator has been condtioned.
When the button is released the normal display in
engineering units will return. The function of this
push button is modified when optional alarms are
fitted to the indicator.
While this button is pushed the indicator will
display the numerical value and analogue
bargraph* the indicator has been calibrated to
display with 4mA input. When released the normal
display in engineering units will return.
While this button is pushed the indicator will
display the numerical value and analogue
bargraph* the indicator has been calibrated to
display with 20mA input. When released the
normal display in engineering units will return.
ENo function in the display mode unless the tare
function is being used.
P + Indicator displays firmware number followed by
version.
P + When optional alarms are fitted provides direct
access to the alarm setpoints if the ‘ACSP’ access
setpoints in display mode function has been
enabled.
P + EProvides access to the configuration menu via
optional security code.
* Only the BA324NE has a bargraph
Issue 2
10th March 2014
BEKA associates Ltd. Old Charlton Rd, Hitchin, Hertfordshire,
SG5 2DA, UK Tel: +44 0)1462 438301 Fax: +44 0)1462 453971
e-mail: [email protected] web: www.beka.co.uk
Abbreviated Instr ction for
BA304NE and BA324NE Ex nA and Ex tc
field mo nting loop powered indicators
The BA304NE & BA324NE are CE marked to show
compliance with the European Explosive Atmospheres
Directive 94 9 EC and the European EMC Directive
2004 108 EC