Dentsply Sirona Nupro RDH 740000 User manual

Mounting Disposable Prophy Angles
(for Nupro RDH™ with U-Style Attachment only
REF740000/740010)
To mount disposable angle to handpiece: Push angle all the
way into handpiece, making sure locating button on handpiece
is seated into notch of angle.
To remove disposable angle from handpiece: Grasp handpiece
with one hand and pull angle from handpiece with other hand.
Mounting Color Bands
To change the color code of the handpiece, remove the color
band as shown, and replace it with a new band of the desired
color.
Installation, Maintenance and Operation Instructions
Indications For Use
Nupro RDH™ handpiece is used for low speed procedures
performed by dental professionals.
Contraindications
None Known.
Warnings
STERILIZE BEFORE USE, SUPPLIED NON-STERILE.
WARNING: This product is intended for use by dental
professionals only. Before operating handpiece, carefully
read and follow these instructions and save them for future
reference. Observe all cautions and warnings, including:
• Handpieces should be heat-sterilized between patients to
prevent cross-contamination which could result in serious
illness or even death from infectious organisms such as HIV
(the virus that causes AIDS) or hepatitis B.
• It is the responsibility of the Dental Healthcare Professional
to determine the appropriate use of this product and to
understand the health of each patient, the dental procedures
being undertaken, industry and governmental agency
regulations, and recommendations and requirements for safe
practice of dentistry.
Precautions
• Do not operate handpiece unless prophy angle or cup is
properly secured. A loose prophy angle could eject from the
handpiece and cause personal injury.
• Do not use angle, attachment or accessory that exhausts air
within the oral cavity when a soft tissue wound is present. Air
pressure may force septic materials into these tissues.
• Before using, allow handpiece to cool completely after
sterilization.
Adverse Reactions
None Known.
Step by Step Instructions
Checking Handpiece Hose
4-Tube Midwest
Operation
To operate the handpiece, simply depress the foot control.
Note: Never operate air motor under the following conditions:
1. At air pressure exceeding 45 p.s.i. (3.1 Atm.).
2. On an alternate hose without adjusting air pressure.
Automatic Oilers
Since the use of automatic oiling does not eliminate the need
for routine maintenance, the oiler should be disconnected.
Do not use oil mist lubrication. (Excess oil may hinder
performance.)
Speed Range
The Nupro RDH™ Handpiece offers exceptional torque at
speeds up to 6000 RPM.
Mounting Right Angle Attachment
(for Nupro RDH™ with Right Angle Attachment only—
REF 740020/740030)
A plastic head wrench has been provided for mounting or
removing the prophy head.
To remove head: Place wrench over prophy head. Loosen head
assembly by turning wrench counterclockwise. Unscrew and
remove head with fingertips.
To install or replace head: Screw prophy head onto sheath
assembly with fingers (clockwise). If the gears do not mesh
properly, back head off 1/4 turn; then retighten. Lock head
onto sheath by tightening with wrench.
Make sure prophy head is tightened securely before operating
handpiece.
Nupro RDH™
Hygienist Handpiece
with Prophy Right Angle
Nupro RDH™
Hygienist Handpiece
with U-style Attachment
REF 740020 / REF 740030 REF 740000 / REF 740010
Replaceable
Head Remove
Make sure all tubes supplying the handpiece hose are properly
connected within the dental unit. Test hose as follows:
1. Hold free end of hose over cuspidor or towel while
alternately depressing drive air pedal on foot control.
Note: The Nupro RDH™ Handpiece does not use chip-air or
water spray. When connecting the Nupro RDH™ Handpiece,
the water and chip air hose tubes can be disconnected and
their supply connection plugged.
2. Check to be sure that drive air is coming out of the
correct tube.
Air Requirements
Nupro RDH™ Handpieces deliver maximum speed and
torque when operated with clean, filtered, moisture-free
air at the recommended operating pressure of 30-40 p.s.i.
Air pressure may be reduced to a minimum of 20 p.s.i. to
decrease operating speed
Initial Maintenance
Follow the reprocessing instructions before using your new
Nupro RDH™ Handpiece.
Manufactured by:
DENTSPLY Professional
1301 Smile Way
York, PA 17404, USA
© 2018 Dentsply Sirona
Printed in U.S.A. Form No. 480652 Rev. 1 (0518)
Reprocessing Instructions
Important: Use only products recommended by Dentsply
Sirona to routinely clean and lubricate your Nupro RDH™
Handpiece.
There are two Maintenance procedures for your Nupro RDH™
handpiece: (1) for maintenance using the Midwest Plus™
Maintenance Kit; (2) for maintenance using Midwest Plus™
Aerosol Spray. Follow the appropriate maintenance procedure
below before using your new RDH handpiece.
This procedure recommends the steps to follow between
patient use to prevent cross-contamination and to ensure
continued trouble-free operation of the handpiece:
5. Apply one drop of Midwest Plus Handpiece Lubricant on
gears inside head. DO NOT fill head full, as excess lubricant
will leak from seal.
Drive
Air
Tube
(Gold)
1. Maintenance Using
Midwest Plus™ Maintenance Kit
Clean External Surface
1. Remove prophy cup by holding sheath of handpiece and
rotating cup in counterclockwise direction.
2. Disconnect handpiece from its supply hose. Spray exterior
surface of handpiece with Midwest Plus™ Handpiece Cleaner.
3. Scrub and rinse external surfaces of handpiece under warm
tap water.
4. Thoroughly dry using gauze, paper towel or air syringe.
Lubricate and Expel
1. Place three drops of Midwest Plus Handpiece Lubricant into
drive air tube (above).
2. Run handpiece on Midwest Handpiece Air Station or other
air source until it reaches normal speed. This ensures that
the internal working parts of the motor are completely
lubricated. Wipe off any excess lubricant on outside of
handpiece with dry 2x2 or tissue.
3. Proceed to Sterilization.
2. Maintenance Using
Midwest Plus™ Aerosol Spray
Scrub and Rinse
1. Remove prophy cup by holding sheath of handpiece and
rotating cup in counterclockwise direction.
2. Disconnect handpiece from its supply hose.
3. Scrub and rinse external surfaces of handpiece under warm
tap water. Use sponge to scrub.
4. Dry thoroughly using gauze, paper towel or air syringe.
Clean • Lubricate • Expel
1. Clean and lubricate with one quick spray of Midwest Plus™
Aerosol Spray using the Midwest Backend Attachment
nozzle into the drive air tube of the handpiece. The drive air
tube is the shorter of the two larger tubes and is gold on
many handpieces.
2. Run the handpiece on Midwest Handpiece Air Station or
other air source for 30 seconds or until normal speed is
reached, and all excess spray is expelled. Dry thoroughly.
3. Proceed to Sterilization.
Sterilization
Enclose the handpiece in a sterilization pouch intended for
steam sterilization. Place the pouched handpiece into the steam
sterilizer per the manufacturer’s instructions.
Gravity Steam Sterilization
Full cycle: 121°C (250°F) for 30 minutes
Full cycle: 132 °C (270°F) for 15 minutes
Dynamic Air Removal
Full cycle: 132°C (270°F) for 4 minutes
Full Cycle: 135°C (275°F) for 3 minutes
Keep handpiece in sterilization pouch until ready to use in the
operatory. No further lubrication is required before use.
Other Maintenance
Weekly or as needed: Place two drops of lubricant on swivel
junction (as shown). Twist swivel to work lubricant into
junction. Wipe handpiece clean.
6. Apply one drop of Midwest Plus Handpiece Lubricant to
gear teeth on handpiece sheath.
7. Reassemble and continue with “Sterilization” in the
Maintenance procedure.
Repair
Should your Nupro RDH™ Handpiece need repair, call
1-800-800-7202 to schedule a free pick-up.
Send to:
Dentsply Sirona
Attn: Air Repair
500 W. College Ave
York, PA 17401
Provide the following information for your repair:
Your complete name and address
Dealer name and address
Nature of repair
Air Repair offers:
• Repairs DOOR TO DOOR IN 2 BUSINESS DAYS
• Genuine Parts
• Expert Troubleshooting and Diagnosis
• Repair Service Warranty equal to the new product warranty
Parts REF
Midwest Plus 8 oz. Spray Cleaner 380145
Maintenance Kit & 2 oz. Lubricant Dropper
Midwest Plus 8 oz. Spray Bottle 380140
Handpiece Cleaner
Midwest Plus 2 oz. Dropper 380130
Handpiece Lubricant
Midwest Plus Cleaner/Lubricant 380080
Aerosol Spray (does not include nozzle)
Nozzle for Midwest Midwest Backend/ 380086
Plus Aerosol Spray Attachment
Midwest Handpiece includes box of 12 380800
Air Station FREE Spray Guards
Midwest Box of 100 380150
Spray Guards
Spray Tips for pkg. of 6 380986
Midwest Plus 8 oz.
Spray Cleaner
Prophy Head Wrench 230611
Color Bands, Orange 760011R Red 760012R
set of 6 Yellow 760013R Violet 760014R
Blue 760015R Green 760016R
The Nupro RDH™ Hygienist Handpiece is compatible with a
wide range of disposable prophy angles and prophy cups/
brushes.
Please see our website at dentsplysirona.com or contact your
local Dentsply Sirona Customer Support Center.
Warranty
Your Nupro RDH™ Handpiece is guaranteed to be free of
defects in materials and workmanship for a period of two (2)
years from its date of purchase — provided that the air motor
has been operated and maintained as prescribed in these
instructions (at the discretion of Dentsply Sirona) and has not
been subjected to apparent misuse, abuse or accident. All
questionable, defective, or loose parts must be returned to the
dealer, with air motor and proof of purchase, transportation
prepaid.
(FOR Nupro RDH™ WITH RIGHT ANGLE ATTACHMENT ONLY
REF 740020 / 740030)
Every 40 prophies, or once a week:
1. Unscrew angle from handpiece.
2. Place angle in beaker of Midwest Plus Handpiece Cleaner
and ultrasonically clean for ten minutes.
3. Scrub and rinse under warm tap water.
4. Dry thoroughly.

This manual suits for next models

1

Other Dentsply Sirona Dental Equipment manuals

Dentsply Sirona Ankylos Balance C User manual

Dentsply Sirona

Dentsply Sirona Ankylos Balance C User manual

Dentsply Sirona Midwest E mini User manual

Dentsply Sirona

Dentsply Sirona Midwest E mini User manual

Dentsply Sirona SINIUS Technical specifications

Dentsply Sirona

Dentsply Sirona SINIUS Technical specifications

Dentsply Sirona Intego Technical specifications

Dentsply Sirona

Dentsply Sirona Intego Technical specifications

Dentsply Sirona Sim Multi Bench User manual

Dentsply Sirona

Dentsply Sirona Sim Multi Bench User manual

Dentsply Sirona SiroLaser Blue User manual

Dentsply Sirona

Dentsply Sirona SiroLaser Blue User manual

Dentsply Sirona Essix TRAY RITE Plastic User manual

Dentsply Sirona

Dentsply Sirona Essix TRAY RITE Plastic User manual

Dentsply Sirona Sidexis 4 User manual

Dentsply Sirona

Dentsply Sirona Sidexis 4 User manual

Dentsply Sirona CEREC AF Connect User manual

Dentsply Sirona

Dentsply Sirona CEREC AF Connect User manual

Dentsply Sirona DAC Universal Touch User manual

Dentsply Sirona

Dentsply Sirona DAC Universal Touch User manual

Dentsply Sirona inLab MC X5 230 V User manual

Dentsply Sirona

Dentsply Sirona inLab MC X5 230 V User manual

Dentsply Sirona Endo IQ Manual

Dentsply Sirona

Dentsply Sirona Endo IQ Manual

Dentsply Sirona Midwest Stylus Plus User manual

Dentsply Sirona

Dentsply Sirona Midwest Stylus Plus User manual

Dentsply Sirona Primescan Connect User manual

Dentsply Sirona

Dentsply Sirona Primescan Connect User manual

Dentsply Sirona Essix PLUS Plastic Manual

Dentsply Sirona

Dentsply Sirona Essix PLUS Plastic Manual

Dentsply Sirona BioBiteCorrector MS Manual

Dentsply Sirona

Dentsply Sirona BioBiteCorrector MS Manual

Dentsply Sirona ProPex II User manual

Dentsply Sirona

Dentsply Sirona ProPex II User manual

Dentsply Sirona Schick AE User manual

Dentsply Sirona

Dentsply Sirona Schick AE User manual

Dentsply Sirona Dyract eXtra User manual

Dentsply Sirona

Dentsply Sirona Dyract eXtra User manual

Dentsply Sirona Tulsa 6:1 User manual

Dentsply Sirona

Dentsply Sirona Tulsa 6:1 User manual

Dentsply Sirona Midwest Stylus Plus User manual

Dentsply Sirona

Dentsply Sirona Midwest Stylus Plus User manual

Dentsply Sirona Compules Tips Gun User manual

Dentsply Sirona

Dentsply Sirona Compules Tips Gun User manual

Dentsply Sirona Retainer Brite User manual

Dentsply Sirona

Dentsply Sirona Retainer Brite User manual

Dentsply Sirona Eclipse Manual

Dentsply Sirona

Dentsply Sirona Eclipse Manual

Popular Dental Equipment manuals by other brands

KaVo GENTLEpower LUX Contra-angle 25 LP Technician's Instructions

KaVo

KaVo GENTLEpower LUX Contra-angle 25 LP Technician's Instructions

Renfert SYMPRO Operating and safety instructions

Renfert

Renfert SYMPRO Operating and safety instructions

BRYANT DENTAL Ignis Gesture A-494322 manual

BRYANT DENTAL

BRYANT DENTAL Ignis Gesture A-494322 manual

Mestra ANETO manual

Mestra

Mestra ANETO manual

DKL CHAIRS D2-AVEO operating instructions

DKL CHAIRS

DKL CHAIRS D2-AVEO operating instructions

Durr Dental VistaCam iX Poly Installation and operating instructions

Durr Dental

Durr Dental VistaCam iX Poly Installation and operating instructions

Aseptico AEU-525S Operation & maintenance manual

Aseptico

Aseptico AEU-525S Operation & maintenance manual

Castellini SKEMA 6 Series operating instructions

Castellini

Castellini SKEMA 6 Series operating instructions

GoodDrs Dr's Light Clever user manual

GoodDrs

GoodDrs Dr's Light Clever user manual

Florida Probe VoiceWorks user manual

Florida Probe

Florida Probe VoiceWorks user manual

Propel Trampolines VPro+ quick start guide

Propel Trampolines

Propel Trampolines VPro+ quick start guide

Shofu BlueShot Instructions for use

Shofu

Shofu BlueShot Instructions for use

Kulzer GLUMA Instructions for use

Kulzer

Kulzer GLUMA Instructions for use

NSK Ti-Max nano65LS Operation manual

NSK

NSK Ti-Max nano65LS Operation manual

DentalEZ StarDental 430 SWL Flex instruction manual

DentalEZ

DentalEZ StarDental 430 SWL Flex instruction manual

Dabi Atlante PROFI NEO owner's manual

Dabi Atlante

Dabi Atlante PROFI NEO owner's manual

Kodak Ngenuity 9000 Series user guide

Kodak

Kodak Ngenuity 9000 Series user guide

Good Doctors Dr's Light CL-AT24 user manual

Good Doctors

Good Doctors Dr's Light CL-AT24 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.