6Configure the Dialer Protocol
1 2 3 4 5 6 7 8 9 10
OFF ON
ADT-SIA
Set switches 1, 2, 3, and 10 ON.
BFSK (1400 Hz ACK Tone)
Set switches 2, 4, and 10 ON.
BFSK (2300 Hz ACK Tone)
Set switches 2 and 10 ON.
DTMF (Includes Contact ID,
High Speed, and 4/2 Express)
Set switches 3 and 10 ON.
DTMF (where dialer retransmits
quickly - includes Contact ID, High
Speed, and 4/2 Express)
Set switches 3, 4, and 10 ON.
FBI Superfast DTMF
(1400 Hz ACK Tone)
Set switches 2, 3, 4, and 10 ON.
FBI Superfast DTMF
(2300 Hz ACK Tone)
Set switches 2, 3, and 10 ON.
Pulse 3/1, 3/1 Checksum
(1400 Hz ACK Tone)
Set switches 1, 4, and 10 ON.
Pulse 3/1, 3/1 Checksum
(2300 Hz ACK Tone)
Set switches 1 and 10 ON.
Pulse 4/2
(Long 1400 Hz ACK Tone)
Set switches 1, 3, 4, and 10 ON.
Pulse 4/2
(Long 2300 Hz ACK Tone)
Set switches 1, 3, and 10 ON.
Radionics Modem II
Set switches 4 and 10 ON.
Radionics Modem IIe and
Modem IIIa2
Set switch 10 ON.
Robofon
Set switches 2, 3, and 4 ON.
Seriee DTMF
Set switches 1, 2, and 3 ON.
Seriee FSK
Set switches 1, 2, 3, and 4 ON.
SIA Bell 103
(110/300 baud, 2016 Hz ACK Tone)
Set switches 1, 2, and 10 ON.
SIA Bell 103
(110/300 baud, 2083 Hz ACK Tone)
Set switches 1 and 2 ON.
SIA V.21 (110/300 baud)
Set switches 1, 2, and 4 ON.
Telim
Set switches 2 and 3 ON.
Locate DIP switches 1 through 10 and set all switches OFF.
Locate the illustration below that matches the dialer format for
your control panel and set the appropriate switches ON.
7
8
10
9
Configure Using the Web
HL
BOSCH 2003
34296K
V1.11
000000AA
C900V2 Router
Connect to Power Supply
-
+
HL
BOSCH 2003
34296K
V1.11
000000AA
C900V2Control Panel
+
Set Supervision
Poll Period
12345678910 12345678910
Connect Local Telephone
HL
BOSCH 2003
34296K
V1.11
000000AA
HL
BOSCH 2003
34296K
V1.11
000000AA
• Connect the telephone to
the C900V2 TELCO jack.
• Set switch 5 ON.
• No telephone
connection
• Set switch 6 ON.
1 2 3 4 5 6 7 8 9 10
12345678910
Set the poll period for your central station (Step 1).
75 seconds 240 seconds
Set switches 8 and 9 ON. Set switches 7, 8, and 9 ON.
1. Connect the +V and –V terminals
on the C900V2 to the appropriate
terminals on the control panel.
2. Connect the C900V2 ground
terminal to earth ground in the
control panel enclosure.
3. Reconnect power to the control
panel.
© 2005 Bosch Security Systems
F01U013273B
2
Installation Complete
1
1Check Status
• Use your computer’s web browser to visit
www.c900v2.com
• Follow the instructions to initialize your central station
account.
• Use your application ID number from Step 1.
HL
BOSCH 2003
34296K
V1.11
000000AA
System Dialer
• The System LED should be flashing green at 5 Hz.
• The Dialer LED should be solid green.
• Verify that the control panel is under central station
supervision by generating a test message from the control
panel.
• Confirm that the central station received the test message.