manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Bosch
  6. •
  7. Transmitter
  8. •
  9. Bosch ISW-EN1235DF User manual

Bosch ISW-EN1235DF User manual

ISW-EN1235DF/SF Installation Guide Fixed Location Transmitters
Trademarks
Panasonic is a registered trademark of Matsushita Electric Industrial
Co., Ltd
SANYO is a registered trademark of SANYO North America
Corporation.
Trademark names are used throughout this document. In most
cases, these designations are claimed as trademarks or registered
trademarks in one or more countries by their respective owners.
Rather than placing a trademark symbol in every occurrence of a
trademark name, Bosch Security Systems, Inc. (hereinafter referred
to as Bosch) uses the names only in an editorial fashion and to the
benefit of the trademark owner with no intention of infringing the
trademark.
Overview
The ISW-EN1235DF (double-button) and ISW-EN1235SF (single-
button) are fixed location transmitters that feature a rugged design
and wall tamper function.
For UL installations, refer to the ISW-EN4216R
Installation Guide (P/N: F01U126806).
1.0 Open the Transmitter Housing
Insert a small, flat-bladed screwdriver into the housing notch, and
gently pry the housing apart.
Figure 1: Transmitter Housing (ISW-EN1235DF shown)
1
1 - Housing notch
Refer to Figure 2 for component locations.
Figure 2: Transmitter Components
2
3
4
1
1 - Reset button
2 - Wall tamper switch with spring
3 - Frequency band pins
4 - Battery
2.0 Select the Frequency Band
Select the appropriate frequency band for your geographic area.
Refer to Figure 3.
If you change the transmitter’s frequency band setting
after initial installation, press the Reset button for the
new setting to take effect.
Figure 3: Frequency Band Settings
1
AUNZ
2
AUNZ
3
AUNZ
1 - North America (902 MHz to 928 MHz) (default)
2 - Australia (915 MHz to 928 MHz)
3 - New Zealand (921 MHz to 928 MHz)
3.0 Mount the Transmitter
•This product is designed to be maintained by
professional security technicians.
•This product is intended for indoor use.
•Manually test this product weekly.
•For UL installations, mount the ISW-EN1235DF/SF
in a concealed area, where operation cannot be
viewed from a public space.
To ensure proper operation, the transmitter must be mounted on a
surface. If the transmitter is not mounted on a surface, it will remain
in a tamper state.
To mount the transmitter:
1. Mount the back plate of the transmitter housing on the
intended surface using the supplied screws.
Refer to Figure 4.
Figure 4: Mounting the Housing Back Plate
1
2
3
4
1 - Mounting surface
2 - Transmitter housing back plate
3 - Mounting holes
4 - Hole for wall tamper switch with spring
© Bosch Security Systems, Inc., 2010
130 Perinton Parkway, Fairport, NY 14450 USA
www.boschsecurity.com
F01U126794-03
Installation Guide
05522A
4/1
0
ISW-EN1235DF/S
F
Page 2 of
2
2. Hook the top of the transmitter housing onto the latch on the
top of the back plate. Refer to Figure 5.
Ensure that the spring on the wall tamper switch
makes contact with the mounting surface through the
hole in the back plate.
Figure 5: Mounting Transmitter to the Housing Back Plate
1
2
3
4
1 - Mounting surface
2 - Transmitter housing
3 - Wall tamper switch with spring
4 - Hole for wall tamper switch with spring
3. Clip the transmitter housing in place onto the back plate.
4.0 Install the Battery
1. Install the battery in the location shown in Figure 2.
2. Press the Reset button.
5.0 Register the Transmitter
You must register the transmitter with the system in order for the
transmitter to be monitored and supervised.
When the transmitter is supervised, it sends a check-in message to
the serial receiver or network coordinator every three minutes.
Each transmitter has a unique factory-programmed identification
number. Refer to the receiver’s documentation for details on
registering a transmitter.
When prompted by the receiver to reset the transmitter, press the
reset button on the transmitter. Refer to Figure 2 on page 1.
Test the transmitter after it is registered with the
system.
To test the transmitter, activate each of the
conditions and ensure an appropriate response.
6.0 Operate the Transmitter
To activate or test the single-button transmitter, press and hold the
button. To activate or test the double-button transmitter, press and
hold both buttons.
Alarm signals are sent multiple times and are indicated by the
blinking transmission LED. When the buttons are released, the
transmitter sends an alarm restoral signal
7.0 Specifications
Power Requirement: 3 VDC at 60 mA
Operating Temperature: 0°C to +60°C (+32°F to +140°F)
Relative Humidity: Up to 90% (non-condensing)
Battery Type: Panasonic CR2, Sanyo CR2, or
equivalent
Typical Battery Life: 3 to 5 years
Compatible Receivers: ISW-EN4216R, ISW-EN7285
UL Listings: UL 365, UL 636, UL 1076, UL 1610

This manual suits for next models

1

Other Bosch Transmitter manuals

Bosch SE88 User manual

Bosch

Bosch SE88 User manual

Bosch RADION RFUN User manual

Bosch

Bosch RADION RFUN User manual

Bosch SE3401 User manual

Bosch

Bosch SE3401 User manual

Bosch SEC-RFPB60M-433 User manual

Bosch

Bosch SEC-RFPB60M-433 User manual

Bosch RF3503E User manual

Bosch

Bosch RF3503E User manual

Bosch ISW-EN1210 Manual

Bosch

Bosch ISW-EN1210 Manual

Bosch ATX-TRM-304T01 User manual

Bosch

Bosch ATX-TRM-304T01 User manual

Bosch Security Systems SE2 Series Manual

Bosch

Bosch Security Systems SE2 Series Manual

Bosch SEC-3402-304 User manual

Bosch

Bosch SEC-3402-304 User manual

Bosch MIYN46 User manual

Bosch

Bosch MIYN46 User manual

Bosch ISW-EN1265 User manual

Bosch

Bosch ISW-EN1265 User manual

Bosch CRS-SB-423FI User manual

Bosch

Bosch CRS-SB-423FI User manual

Bosch S35 User manual

Bosch

Bosch S35 User manual

Bosch CRS-RM-905FI User manual

Bosch

Bosch CRS-RM-905FI User manual

Bosch CRS-NC-S37L-US User manual

Bosch

Bosch CRS-NC-S37L-US User manual

Bosch SE-TRM-433T01 User manual

Bosch

Bosch SE-TRM-433T01 User manual

Bosch RFKF-FB User manual

Bosch

Bosch RFKF-FB User manual

Bosch NurseCall N46 User manual

Bosch

Bosch NurseCall N46 User manual

Bosch CRS-NC-S37L User manual

Bosch

Bosch CRS-NC-S37L User manual

Bosch ATX-TRM-304T01 User manual

Bosch

Bosch ATX-TRM-304T01 User manual

Bosch CRS-NC-S37E-ACC User manual

Bosch

Bosch CRS-NC-S37E-ACC User manual

Bosch RF3401E User manual

Bosch

Bosch RF3401E User manual

Bosch ISW-EN1233 User manual

Bosch

Bosch ISW-EN1233 User manual

Bosch CRS-SB-424FI User manual

Bosch

Bosch CRS-SB-424FI User manual

Popular Transmitter manuals by other brands

Vishay DXP10 Operator's manual

Vishay

Vishay DXP10 Operator's manual

Endress+Hauser Liquiline M OM42 technical information

Endress+Hauser

Endress+Hauser Liquiline M OM42 technical information

Evikon PluraSens E2618 Series user manual

Evikon

Evikon PluraSens E2618 Series user manual

Emerson Rosemount Reference manual

Emerson

Emerson Rosemount Reference manual

RKI Instruments 65-2660RK-01-04 Operator's manual

RKI Instruments

RKI Instruments 65-2660RK-01-04 Operator's manual

weinor BiEasy 1MW-3V operating instructions

weinor

weinor BiEasy 1MW-3V operating instructions

anko 42902133 user manual

anko

anko 42902133 user manual

BYONICS Microtrak-2001 manual

BYONICS

BYONICS Microtrak-2001 manual

Extron electronics PVT CV D user guide

Extron electronics

Extron electronics PVT CV D user guide

Eldat Easywave RTS39 Series quick start guide

Eldat

Eldat Easywave RTS39 Series quick start guide

EUTECH INSTRUMENTS 2-WIRE DISSOLVED OXYGEN TRANSMITTER operating instructions

EUTECH INSTRUMENTS

EUTECH INSTRUMENTS 2-WIRE DISSOLVED OXYGEN TRANSMITTER operating instructions

Tele Radio T7-14 User instructions

Tele Radio

Tele Radio T7-14 User instructions

HK Instruments CDT Series installation instructions

HK Instruments

HK Instruments CDT Series installation instructions

Savio TR-13 user manual

Savio

Savio TR-13 user manual

AMG AMG4713E instruction manual

AMG

AMG AMG4713E instruction manual

Farpointe Data WRT-4 installation guide

Farpointe Data

Farpointe Data WRT-4 installation guide

RKI Instruments M2A Operator's manual

RKI Instruments

RKI Instruments M2A Operator's manual

Televes 238201 user guide

Televes

Televes 238201 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.