2
160 cm
item 332710
max. ø 5mm
item 332711
Conguration
The device must be congured (only phisically) as follows:
P - entrance panel number
The congurator in socket P of the speaker module assigns to this a recognition number
inside the system. The numbering of the entrance panels must always start from P=0.
The entrance panel congured with P=0 must be a common (or main) entrance panel.
N - call number
Assigns the correspondence between the entrance panel pushbuttons, and the audio
handsets.
In common entrance panels made using pushbutton modules, 1 must be inserted in N of
the speaker module. In secondary entrance panels, the number of the rst riser handset
must be inserted in N.
S - type of call signal
The conguration of S determines the call tone of SPRINT handsets.
One can thus dierentiate the calls from dierent entrance panels.
T - Door lock relay timing
0= No
congurator
4 sec.
1
1 sec. 6 sec. 8 sec. 10 sec.
2
2 sec.
3
3 sec. as
pushbutt.
4* 5 6 7
congurator number
Congurator 0 1 2 3
Type of bell 2-tone 2-tone 2-tone One-tone
1200Hz 1200Hz 1200Hz 1200Hz
600Hz 0 Hz 2400Hz
Table for SPRINT handset call signal
For the SWING, PIVOT, POLYX and AXOLUTE handsets, the S congurator associates the
entrance panel to the bell programmed in the same apartment. It is possible to chose
between 16 dierent bells. In one-family systems S=9 to congure the general call
(all the system handsets ring at the same time).
Inside the MINISFERA audio speaker module are JUMPERS that can be used for
performing the following functions:
• Jumper - EP call con rmation
To eliminate the entrance panel call conrmation sound remove the JUMPER .
• Jumper - staircase light switching on with call key
To switch on the staircase the light from the entrance panel using the last call key,
remove the JUMPER .
• Jumper – call pushbutton exclusion
Connect the jumper to exclude the call pushbutton.
NOTE: disable the pushbuttons based on the false poles, and the single, or the double
keys connected.
Example - To use the double key the upper level call must be disabled.
Double
keys
call pushbutton enabled call pushbutton disabled
Flush mounted installation
Installation
160 cm
item 332710
max. ø 5mm
item 332711
Wall mounted installation
BT00119-b-UK
* Operation as pushbutton for 10 sec. max, after which standby mode is activated.
To extend operation time over 10 seconds, use actuator item 346200 congured with
MOD=5.
342708