Operating Instructions Type 6511
Design:
5-way solenoid valve, internally piloted
Seal Materials and Fluids handled:
See Table 1.
Fluid and Ambient Temperature:
For Hazardous Locations Div. 1 (T4 rated)
Max. Ambient Temperature 104 °F (40 °C)
Max. Fluid Temperature 140 °F (60 °C)
For Hazardous Locations Div. 1 (T6 rated)
Max. Ambient Temperature 104 °F (40 °C)
Max. Fluid Temperature 140 °F (60 °C)
For Intrinsically Safe Apparatus for use in Class I, II and III,
Division 1 Hazardous Locations.
Max. Ambient Temperature 140 °F (60 °C)
Max. Fluid Temperature 140 °F (60 °C)
For Hazardous Locations Div. 2 and Ordinary Locations:
See Table 1.
Pressure Range:
Maximum inlet pressure see label on valve.
Installation:
Before installing valve ensure that piping etc. is free of foreign
matter (metal shavings, pipe sealing materials, welding scale
etc.). Installation as required but preferable with coil uppermost.
Installation in this position tends to prevent foreign matter
remaining in core tube (increased life). Do not put any loads on
coil unit.
PTFE tape is recommended for sealing ports. Mounting is
accomplished by means of four M4 x 8 mm tapped holes
located on the valve underside. Letters on valve body indicate
pressure port, exhaust and outlet of the valve.
Marking (example):
Body Material
PA = Polyamide
AL = Aluminium
Seal Material
NBR = NBR
FKM = FKM
Circuit function
H = 5-way
Item No.
Voltage / Frequency / Power Consumption
Maximum Pressure
Approvals
The valve is either approved as
General Purpose valve for Hazardous Locations
Class I, Division 1, Group A, B, C, D
Class II, Division 1, Group E, F, G
Class III, Division 1 and 2
Operating Temperature T 4
or General Purpose valve for Hazardous Locations
Class I, Division 1, Group A, B, C, D
Class II, Division 1, Group E, F, G
Class III, Division 1 and 2
Operating Temperature T 6
or Intrinsically Safe Apparatus for Hazardous Locations
Class I, Division 1, Group A, B, C, D
Class II, Division 1, Group E, F, G
Class III, Division 1 and 2
Operating Temperature T 6
or FM approved as
Nonincendive for Hazardous Locations
Class I, Division 2, Group A, B, C, D
Class II, Division 2, Group F, G
Class III, Division 1 and 2
Operating Temperature T 4
UL listed for General Purpose
CSA approved for General Purpose
See label on the valve.
Table 1 Seal Materials
Fluid Temperatures [°F] PB Buna “N”
NBR
Air Fluid Temp. + 10 to +122 + 10 to +122
Ambient + 10 to +130 + 10 to +130
Operating Instructions 0605/10_EU-EN_00801862
Operating Instructions
Wiring Diagram
Electrical Connection Type 2509
Electrical Connection:
Ensure supply voltage/frequency corresponds with that on label.
Voltage tolerance is ± 10 %.
Available Electrical Connections see “Marking”.
Wiring diagram see above.
For this product to be considered UL-listed and CSA approved
for General Purpose and FM approved for Hazardous Locations
Division 2, it must be in conjunction with the type 2509 cable plug
connector (Electrically Operated Valves Parts, YSYI2).
The connector and gasket must be assembled to the valve with the
screw provided after the connection of the wire leads. This valve
and connector assembly is delivered together and is to be used as
one unit.
For valves to be used in Intrinsically Safe Applications the positive
pole is identified by a “+” on the pin or wire No. 1 has to be con-
nected to the “+”.
See Control Drawing for the Rules of Interconnection.
Warning:
All valves to be used in Intrinsically Safe Applications must be
clearly marked as Intrinsically Safe Apparatus.
Trouble-Shooting:
Check port connections, minimum operating pressure differential
if required and supply voltage. Ensure pilot hole in piston is clear
and pilot bore in the valve outlet is not abstracted. If core does not
pull in, check for short circuit, coil burn-out or foreign matter im-
peding core movement. A jammed or missing core causes the coil
to overheat in the case of AC supply.
Warning:
These products are designed to operate in a wide variety of ap-
plications, it is the user’s responsibility to select a model that is
appropriate for the application. This product is designed to be
installed only by suitably qualified and trained personnel.
Specifications should not be exceeded under any circumstances.
The torque for the terminal screw on type 2509 is 0,5 Nm
(4,4 lbf-in.).
Changes made to this product will render any applicable warranty
null and avoid.
Specifications subject to change without notice.
Any questions? Please call Bürkert Contromatic Technical Service
at (949) 223 31 00.
Power*
Power*
Ground (green dot)
* Orientation is not important
Germany
Contact address:
Bürkert Fluid Control Systems
Sales Center
Chr.-Bürkert-Str. 13-17
D-74653 Ingelfingen
Tel. + 49 (0) 7940 - 10 91 111
Fax + 49 (0) 7940 - 10 91 448
E-mail: [email protected]
International
Contact addresses can be found on the Internet at:
www.burkert.com Bürkert Company Locations

Other Burkert Control Unit manuals

Burkert 5282 User manual

Burkert

Burkert 5282 User manual

Burkert 3232 User manual

Burkert

Burkert 3232 User manual

Burkert 6221 User manual

Burkert

Burkert 6221 User manual

Burkert 2006 User manual

Burkert

Burkert 2006 User manual

Burkert 6240 User manual

Burkert

Burkert 6240 User manual

Burkert 8653 AirLINE Field User manual

Burkert

Burkert 8653 AirLINE Field User manual

Burkert AirLINE 8652 Series User manual

Burkert

Burkert AirLINE 8652 Series User manual

Burkert 2103 Series User manual

Burkert

Burkert 2103 Series User manual

Burkert 6407 User manual

Burkert

Burkert 6407 User manual

Burkert 2100 series User manual

Burkert

Burkert 2100 series User manual

Burkert 0131 User manual

Burkert

Burkert 0131 User manual

Burkert 2035 User manual

Burkert

Burkert 2035 User manual

Burkert 2301 Series User manual

Burkert

Burkert 2301 Series User manual

Burkert 85343 User manual

Burkert

Burkert 85343 User manual

Burkert 2610 User manual

Burkert

Burkert 2610 User manual

Burkert 8681 User manual

Burkert

Burkert 8681 User manual

Burkert 6650 User manual

Burkert

Burkert 6650 User manual

Burkert 2031 INOX User manual

Burkert

Burkert 2031 INOX User manual

Burkert 2100 series User manual

Burkert

Burkert 2100 series User manual

Burkert FieldConnect ME64 User manual

Burkert

Burkert FieldConnect ME64 User manual

Burkert 6213 EV User manual

Burkert

Burkert 6213 EV User manual

Burkert 3360 User manual

Burkert

Burkert 3360 User manual

Burkert 2301 Series User manual

Burkert

Burkert 2301 Series User manual

Burkert Type 2000 User manual

Burkert

Burkert Type 2000 User manual

Popular Control Unit manuals by other brands

Texas Instruments TPS25200EVM-618 user guide

Texas Instruments

Texas Instruments TPS25200EVM-618 user guide

TECHCON TS5540 user guide

TECHCON

TECHCON TS5540 user guide

Telnova F6088 user manual

Telnova

Telnova F6088 user manual

Espressif ESP01 quick start guide

Espressif

Espressif ESP01 quick start guide

MEDENUS SL 10 Operating and maintenance instructions

MEDENUS

MEDENUS SL 10 Operating and maintenance instructions

HP E1407A Installation and user manual

HP

HP E1407A Installation and user manual

TLV DR20 instruction manual

TLV

TLV DR20 instruction manual

Honeywell Braukmann DR300 installation instructions

Honeywell

Honeywell Braukmann DR300 installation instructions

G-U RZ 25 Installation and operating instructions

G-U

G-U RZ 25 Installation and operating instructions

Gefa Domino AT 100 Series Instructions for use

Gefa

Gefa Domino AT 100 Series Instructions for use

Pentair FLECK 5800 Service manual

Pentair

Pentair FLECK 5800 Service manual

Comeval UNIWAT CH Series Installation, operating and maintenance manual

Comeval

Comeval UNIWAT CH Series Installation, operating and maintenance manual

National Instruments FieldPoint FP-1000 operating instructions

National Instruments

National Instruments FieldPoint FP-1000 operating instructions

Phasemation CM-2200 owner's manual

Phasemation

Phasemation CM-2200 owner's manual

Sennheiser SL Interpreter quick guide

Sennheiser

Sennheiser SL Interpreter quick guide

Honeywell SOMAT39 user manual

Honeywell

Honeywell SOMAT39 user manual

VXI VT1419A Multifunction Plus user manual

VXI

VXI VT1419A Multifunction Plus user manual

salmson Siriux DP-BUS Installation and operating instructions

salmson

salmson Siriux DP-BUS Installation and operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.