manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. CAME
  6. •
  7. Accessories
  8. •
  9. CAME MR8534 User manual

CAME MR8534 User manual

MR8534/MR8570/MR8590
1
2
3
4
5
6
7
8
9
10
11
TECHNICAL SPECIFICATIONS
1. profile
2. supporting clip
3. main connector
4. DIP-switch
5. calibration screw
6. receiver
DESCRIPTION
ENGLISH
Safety sensor for automatic swing doors
7. end cap
8. clip with angle adjustment screw
9. transmitter (TX)
10. push button
11. front face
active infrared with background suppression
400 mm (W) x 70 mm (D) (at 2 m mounting height; 4 spots active)
1.3 m to 3.5 m
64 ms (typ)
infinite
12 V - 24 V AC +/-10% ; 12 V - 30 V DC -5%/+10%
(to be operated from SELV compatible power supplies only)
95 mA @ 24 V AC/ 70 mA @ 24 V DC; 170 mA @ 12 V AC/ 130 mA @ 12 V DC (MASTER)
85 mA @ 24 V AC/ 60 mA @ 24 V DC; 180 mA @ 12 V AC/ 113 mA @ 12 V DC (other modules)
2 relays (free of potential contact)
42 V AC/DC
1 A (resistive)
30 W (DC) / 60 VA (AC)
1 optocoupler (free of potential contact)
30 V
high: >10 V DC; low: <1 V DC
4 (up to 6 if 24 V DC)
min. 5% at IR-wavelength of 850 nm
IP53
-25 °C to +55 °C; 0-95% relative humidity, non condensing
20 years
EMC 2004/108/EC; MD 2006/42/EC; ROHS 2 2011/65/EU
DIN 18650-1:2012 ch. 5.7.4; BS 7036-2:1996*; EN 16005:2012 ch. 4.6.8;
EN 12978:2003 + A1:2009; EN 61508:2010; IEC 61496-2:2006; BGR 232;
EN ISO 13849-1:2008 Performance Level «c» CAT. 2
(under the condition that the door control system monitors the sensor at least once per door cycle)
Technology:
Emission field:
Mounting height:
Reaction time:
Max. presence time:
Supply voltage:
Max current consumption:
Output:
Max. contact voltage
Max. contact current
Max. switching power
Input:
Max. contact voltage:
Voltage threshold:
Max. number of modules:
Reflectivity:
Degree of protection:
Temperature range:
Expected lifetime:
Norm conformity:
S
pecifications are subject to changes without prior notice
.
A
ll values measured in speci
fi
c conditions.
* max. mounting height for BS 7036-conformity (UK): 3.25 m
Other use of the device is outside the permitted purpose and can not be guaranteed by the manufacturer.
The manufacturer cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor.
User’s Guide for product version 0400 and higher. See product label for serial number.
MR8534-70-90 / FA00026M06 ☜󱽚☞ 4SAFE / 42.8280 / v1 - 02.15
1
2
3
2 cm
12-24 V
AC-DC
COM
NC
NO
COM
NO
NC
NO NC
*
*
MR8534-70-90 / FA00026M06 ☜󱽚☞ 4SAFE / 42.8280 / v1 - 02.15
MOUNTING THE PROFILE
POSITIONING THE MODULES
WIRING
GREEN
BROWN
YELLOW
WHITE
BLACK
PINK
GREY
VIOLET
RED**
BLUE**
POWER SUPPLY
STOP IMPULSE
Opening side of door
REOPENING IMPULSE
Closing side of door
TEST OUTPUT***
The transmitter (TX) should be placed next to
the door edges that need to be protected.
The angle adjustment clip should be next to
the transmitter.
Turn the module if necessary.
When a module needs to be turned:
1. detach the clips
2. turn them by 180°
3. reattach
NO POWER
NO DETECTION
DETECTION
The module connected to the door controller
becomes the MASTER.
Plug the SLAVE
CABLE between
the modules in
one of the two
placements.
Mount the profiles as close as possible to the closing edge. Leave 2 cm
for the black end caps. Take the position of the white clips into account
before drilling and fastening the screws.
* Output status when sensor is operational
** For compliance with EN 16005 and DIN 18650, connection to door controller test output is required.
*** If door controller is not tested: conncect BLUE to 0 V and RED to +12 V - 30 V DC.
To loosen the modules, please use
a screwdriver.
MR8534-70-90 / FA00026M06 ☜󱽚☞ 4SAFE / 42.8280 / v1 - 02.15
4
6
5
4
5
X
MR8534-70-90 / FA00026M06 ☜󱽚☞ 4SAFE / 42.8280 / v1 - 02.15
SETTINGS
DOOR SAFETY CHECK
CALIBRATION
IMPORTANT: Test the good
functioning of the installation
before leaving the premises.
If necessary, position spots
closer to or away from the door
and relaunch a calibration.
After changing a DIP-switch, the orange LED flashes.
A LONG push on the push button of the MASTER
confirms the settings of ALL MODULES.
Afterwards, a number of green flashes (x) indicates
the number of connected modules.
A SHORT push on the button of the MASTER launches a
calibration on ALL MODULES.
Do not stand in the detection field!
When the LED is off on all modules, the detection zone is OK.
The detection zone is too short:
turn the screw clockwise.
The detection zone is too long:
turn the screw anticlockwise.
Step out of the detection field.
If necessary, change angle or switch off background (DIP 3 = OFF).
Launch a new calibration.
The flashing speed of
the LED increases when
approaching the optimal
position.
MOUNTING
SIDE
FREQUENCY BACKGROUND UNCOVERED
ZONE
RELAY 1
STOP
RELAY 2
REOPENING
FREQ A
FREQ B
ON
OFF
HIGH*
LOW
ON
OFF
LED during detection:
R1 > RED
R2 > GREEN
Set different
frequencies on
modules close to
each other.
Not enough background
reflectivity: switch to OFF
Approximate values at 2 m:
high= 30 cm, low = 15 cm
RED-GREEN OFF
GREEN
RED
ORANGE
ORANGE GREEN OFF
FACTORY VALUE
* Recommended for most applications.
Moutning height > 3 m: set to LOW for
EN 16005 and DIN 18650-conformity.
MR8534-70-90 / FA00026M06 ☜󱽚☞ 4SAFE / 42.8280 / v1 - 02.15
Came S.p.A.- Via Martiri Della Liberta 15 - IT-31030 DOSSON DI CASIER (TV)
TEL (+39) 0422 4940 - FAX (+39) 0422 4941 - [email protected] - www.came.it
2
1
4
5
1
1
3
1
1
2
1
2
1
2
1
2
1
1
2
1
2
3
1
3
4
2
4
LED-SIGNALS
The ORANGE LED
flashes 1 x
every 3 seconds.
Bad calibration
The ORANGE LED is
on permanently.
The ORANGE LED
flashes quickly.
The RED or GREEN
LED is ON sporadicly
or permanently.
Launch a calibration.
Send the sensor back for a technical check-up.
Corfirm the DIP-switch setting:
long push on the push button.
Cut and restore power supply.
If orange LED flashes again, replace sensor.
The sensor does not
react, but a calibration
can be launched.
Chech wiring.
- Door control with test:
Connect RED and BLUE wires to test output.
- Door control without test:
Connect BLUE to 0 V and RED to +12 V - 30 V DC.
The ORANGE LED
flashes 2 x
every 3 seconds.
The ORANGE LED
flashes 3 x
every 3 seconds.
The ORANGE LED
flashes 4 x
every 3 seconds.
The ORANGE LED
flashes 5 x
every 3 seconds.
Check power supply (tension, capacity).
Reduce the cable length or change cable.
Check wiring between modules.
Launch a module count: long push on push button
of MASTER.
Launch a new calibration.
Step out of the detection field.
Change angle of spots.
Switch off background (DIP 3: OFF).
Power supply is out of limit.
The sensor signals an
internal fault.
Bad adjustment of the
uncovered zone.
The monitoring is activated,
but the test input is not
powered.
Communication error
between modules.
The sensor receives
not enough IR-energy.
The sensor encounters a
memory problem.
DIP-switch setting
awaiting confirmation.
The sensor is disturbed by
lamps or another sensor.
Select a different frequency for each module (DIP 2).
Launch a calibration.
Calibration error Check mounting height.
Change position of calibration screw.
Launch a new calibration.
Switch off background (DIP3: OFF)
Check if the DIP-switch 4 is in correct position.
Launch a calibration.
CAME hereby declares that MR8534/MR8570/MR8590 is in conformity with the basic requirements and the other
relevant provisions of the directives 1999/5/EC, 2004/108/EC and 2006/42/CE.
Only for EC countries: According to the European Guideline 2002/96/EC for Waste Electrical and Electronic Equipment
(WEEE)
Original upon request.
BUY-TO-SELL PRODUCT
SAFETY INSTRUCTIONS
The manufacturer of the door system is responsible for carrying out a risk assessment and installing the sensor and the door system
in compliance with applicable national and international regulations and standards on door safety and if applicable, the machinery directive 2006/42/EC.
Only trained and qualified personnel may install and setup the sensor. The warranty is void if unauthorized repairs are made or attempted by unauthorized personnel. Avoid
touching any electronic and optical components.
MR8534-70-90 / FA00026M06 ☜󱽚Original instructions󱽚☞ 4SAFE / 42.8280 / v1 - 02.15

Other manuals for MR8534

1

This manual suits for next models

2

Other CAME Accessories manuals

CAME MR8204 User manual

CAME

CAME MR8204 User manual

CAME 001SIRCEWL User manual

CAME

CAME 001SIRCEWL User manual

CAME MR8003 User manual

CAME

CAME MR8003 User manual

CAME DNF10 User manual

CAME

CAME DNF10 User manual

CAME MR8106 User manual

CAME

CAME MR8106 User manual

CAME MR8334 User manual

CAME

CAME MR8334 User manual

CAME MR8701 User manual

CAME

CAME MR8701 User manual

CAME MR8700 User manual

CAME

CAME MR8700 User manual

CAME R Series Instruction manual

CAME

CAME R Series Instruction manual

CAME MR8107 User manual

CAME

CAME MR8107 User manual

CAME SIPA08 User manual

CAME

CAME SIPA08 User manual

CAME STRAUSS LIGHT KLT User manual

CAME

CAME STRAUSS LIGHT KLT User manual

CAME MR8700 User manual

CAME

CAME MR8700 User manual

CAME RIOPH8WS User manual

CAME

CAME RIOPH8WS User manual

CAME DIR10U User manual

CAME

CAME DIR10U User manual

CAME DELTA-E User manual

CAME

CAME DELTA-E User manual

Popular Accessories manuals by other brands

HoMedics Defender Gosafe DF-MS100 manual

HoMedics

HoMedics Defender Gosafe DF-MS100 manual

Velleman 959 operating manual

Velleman

Velleman 959 operating manual

AEB 1300 Assembly Instructions and Guarantee

AEB

AEB 1300 Assembly Instructions and Guarantee

Fibar Group FGBS221 operating manual

Fibar Group

Fibar Group FGBS221 operating manual

Philips DLA81001H brochure

Philips

Philips DLA81001H brochure

WAGNER STACK PROBE owner's manual

WAGNER

WAGNER STACK PROBE owner's manual

Leuze electronic IPS 258i Original operating instructions

Leuze electronic

Leuze electronic IPS 258i Original operating instructions

UPPAbaby RumbleSeat manual

UPPAbaby

UPPAbaby RumbleSeat manual

ABB tacteo KNX product manual

ABB

ABB tacteo KNX product manual

Siemens SIMATIC MOBY D System manual

Siemens

Siemens SIMATIC MOBY D System manual

Polaris 2882824 manual

Polaris

Polaris 2882824 manual

Florihana FLD013 user manual

Florihana

Florihana FLD013 user manual

echoflex TAP-21C installation guide

echoflex

echoflex TAP-21C installation guide

VOLTCRAFT VC-SL16000 operating instructions

VOLTCRAFT

VOLTCRAFT VC-SL16000 operating instructions

Steiss 8 Series user manual

Steiss

Steiss 8 Series user manual

Greengate ONW-P-1001-MV-W installation instructions

Greengate

Greengate ONW-P-1001-MV-W installation instructions

ARC MEST-1701 manual

ARC

ARC MEST-1701 manual

Dometic A&E WeatherPRO user manual

Dometic

Dometic A&E WeatherPRO user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.