2.0 01/2009 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
ENGLISH
N.B.: If the cable length differs from that specified in the table, then you must determine the proper cable diameter based on the actual
power draw from the connected devices and according to the CEI EN 60204-1 standards.
For connections that require several, sequential loads, the sizes given on the table must be re-evaluated based on actual power draw
and distances.
When connecting products that are not specified in this manual, please follow the documentation provided with said products.
6.1 Cable and type and section
Connections Type
of cable
Length of cable
1 < 10 m
Length of cable
10 < 20 m
Length of cable
20 < 30 m
Control panel power supply
FROR CEI
20-22
CEI EN
50267-2-1
3G x 1,5 mm23G x 1,5 mm23G x 2,5 mm2
Motor power supply 3G x 1,5 mm23G x 1,5 mm23G x 2,5 mm2
flashing lamp 2 x 1,5 mm22 x 1,5 mm22 x 1,5 mm2
Transmitter photocells 2 x 0,5 mm22 x 0.5 mm22 x 0,5 mm2
Receiver photocells 4 x 0,5 mm24 x 0,5 mm24 x 0,5 mm2
Power supply to accessories 2 x 0,5 mm22 x 0,5 mm22 x 1 mm2
Control and safety devices 2 x 0,5 mm22 x 0,5 mm22 x 0,5 mm2
Encoder connection 2402C 22AWG max. 30 m
Antenna connection RG58 max. 10 m
6 Electrical connections
6) After the adjustments and settings, fix the cover
using the provided screws.
5) Snap the cover into place onto the hinges. Close it and fix it
using the provided screws.
Terminals for powering the following accessories:
- 24V A.C. Overall power allowed: 20W
Power supply to accessories
Power supply
230V (A.C.) 50/60 Hz
Electrolock connection
(12V - 15W max)
Possible output of the radio
receiver’s second channel
(N.O. socket).
Socket rating: 1A-24V (D.C.).
6.2 Electrical connections