ENGLISH
The data and information provided in this manual are to be considered susceptible to change at any time without warning, by CAME cancelli automatici s.p.a.
Electrical connections
Antenna connection
EN
(N.C.) contact for «re-open during closing phase»
10-E1
2-7
2-C3
1-2
10-11
10-5
2-C1
L-N
230V (a.c.) Power, 50/60Hz frequency
Terminals for powering the following accessories:
- 24V A.C. normally;
- 24V D.C. when the emergency batteries are
working;
Maximum allowed power: 37W
Stop button (N.C. contact)
Key selector and/or command button (N.O. contact)
Movement flashing light (Contact range: 24V
– 25W max)
«partial stop» (N.C.) contact
Open-gate status light (contact range: 24V – 3W max)
2-3P
Key selector and/or partial opening button (N.O.
contact)
2-C7
«Open while closing»(N.C.) contact
(Sensitive edges).
2-C8
«close while opening» (N.C.)contact
(Sensitive edges).
Connection limit switch opens (N.C.)
Connection limit switch closes (N.C.)
F-FA
F-FC
+
E
-
M-N
24V (d.c.) motor with Encoder
- White
- Brown Encoder
- Green
7
ENGLISH
The data and information provided in this manual are to be considered susceptible to change at any time without warning, by CAME cancelli automatici s.p.a.
Electrical connections
Antenna connection
EN
(N.C.) contact for «re-open during closing phase»
10-E1
2-7
2-C3
1-2
10-11
10-5
2-C1
L-N
230V (a.c.) Power, 50/60Hz frequency
Terminals for powering the following accessories:
- 24V A.C. normally;
- 24V D.C. when the emergency batteries are
working;
Maximum allowed power: 37W
Stop button (N.C. contact)
Key selector and/or command button (N.O. contact)
Movement flashing light (Contact range: 24V
– 25W max)
«partial stop» (N.C.) contact
Open-gate status light (contact range: 24V – 3W max)
2-3P
Key selector and/or partial opening button (N.O.
contact)
2-C7
«Open while closing»(N.C.) contact
(Sensitive edges).
2-C8
«close while opening» (N.C.)contact
(Sensitive edges).
Connection limit switch opens (N.C.)
Connection limit switch closes (N.C.)
F-FA
F-FC
+
E
-
M-N
24V (d.c.) motor with Encoder
- White
- Brown Encoder
- Green

8
ENGLISH
The data and information provided in this manual are to be considered susceptible to change at any time without warning, by CAME cancelli automatici s..p.a.
Function selector
1 ON - Automatic Closing - The automatic closing timer activates at the end of the opening gate run. The pre-set time is adjustable, and
is in any case conditioned by the activation of any safety devices, and does not activate after a total safety “stop” or during a
blackout.
2 ON - "Open-stop-close-stop" function with [2-7] button and radio transmitter (fitted with inserted radiofrequency card).
2 OFF - "Open-close" function with [2-7] button and radio transmitter ((fitted with inserted radiofrequency card).
3 ON - "Open only" function with radio transmitter ((fitted with inserted radiofrequency card).
4 ON - Pre-Opening and closing flasher - Following and opening and closing command, the flasher connected to [10-E1], flashes for 5
seconds before motion begins.
5 ON - Obstacle detected -When motor is stopped (gate closed or after a total stop command) it prevents any movement if safety devices,
such as photocells, detect any obstacles.
6 ON - Maintained action - The gate works by keeping button pressed (one 2-3P opening button , and one closing button).
7 ON - Functioning of the photocells’ safety test - Allows the card to check the efficiency of any safety devices (i.e. photocells) after
every opening or closing command.
8 OFF - Total stop - This function stops the gate and then excludes any automatic closing cycle; to set in motion again, use either the
keypad or transmitter. Insert the safety device in [1-2]; If unused, set DIP switch to ON.
9 OFF - Opening during closing - If the photocells detect an obstacle during gate’s closing, gate motion is inverted until fully opened;
connect the safety device to terminals [2-C1]; if unused, set DIP switch to ON.
10 OFF -Partial stop - Gate stop when obstacle is detected by the safety device; once obstacle is removed, the gate remains still or closes
if automatic closing is activated. Connect the safety device to terminal [2-C3]; if unused, set the DIP switch to ON.
b
8
ENGLISH
The data and information provided in this manual are to be considered susceptible to change at any time without warning, by CAME cancelli automatici s..p.a.
Function selector
1 ON - Automatic Closing - The automatic closing timer activates at the end of the opening gate run. The pre-set time is adjustable, and
is in any case conditioned by the activation of any safety devices, and does not activate after a total safety “stop” or during a
blackout.
2 ON - "Open-stop-close-stop" function with [2-7] button and radio transmitter (fitted with inserted radiofrequency card).
2 OFF - "Open-close" function with [2-7] button and radio transmitter ((fitted with inserted radiofrequency card).
3 ON - "Open only" function with radio transmitter ((fitted with inserted radiofrequency card).
4 ON - Pre-Opening and closing flasher - Following and opening and closing command, the flasher connected to [10-E1], flashes for 5
seconds before motion begins.
5 ON - Obstacle detected -When motor is stopped (gate closed or after a total stop command) it prevents any movement if safety devices,
such as photocells, detect any obstacles.
6 ON - Maintained action - The gate works by keeping button pressed (one 2-3P opening button , and one closing button).
7 ON - Functioning of the photocells’ safety test - Allows the card to check the efficiency of any safety devices (i.e. photocells) after
every opening or closing command.
8 OFF - Total stop - This function stops the gate and then excludes any automatic closing cycle; to set in motion again, use either the
keypad or transmitter. Insert the safety device in [1-2]; If unused, set DIP switch to ON.
9 OFF - Opening during closing - If the photocells detect an obstacle during gate’s closing, gate motion is inverted until fully opened;
connect the safety device to terminals [2-C1]; if unused, set DIP switch to ON.
10 OFF -Partial stop - Gate stop when obstacle is detected by the safety device; once obstacle is removed, the gate remains still or closes
if automatic closing is activated. Connect the safety device to terminal [2-C3]; if unused, set the DIP switch to ON.
b

9
ENGLISH
The data and information provided in this manual are to be considered susceptible to change at any time without warning, by CAME cancelli automatici s.p.a.
Activating the radio command
- Connect the antenna’s RG58 cable to the apposite terminals .
- Insert the radio frequency card into the electronic card AFTER DISCONNECTING THE POWER (and disconnecting any batteries).
N.B.: the electronic card picks up the radiofrequency card on when it is running on power.
- Keep pressed the PROG button on the electronic card. The LED will flash.
- Press the button of transmitter to memorise. The LED will stay on to signal memorisation.
Memorisation
c
d
f
e
Settings
- «A.C.T.» Sets the waiting time while open. Once this time has elapsed, closing automatically takes place. The
waiting time may be set from 1 to 150 seconds.
- «PAR.OP.» Sets the gate’s partial opening. By pushing the partial opening button connected at 2-3P, the gate opens
depending on the length of the gate.
- «SLOW S.» Sets the amperometric sensitivity that controls the force generated by the motor during slow down; if the
force exceed the set level, the system intervenes by inverting the direction of motion.
- «RUN S.» Sets the amperometric sensitivity that controls the force generated by the motor during movement; if the
force exceeds the set level, the system intervenes by inverting the direction of motion.
- «SLOW V.» Sets the gate’s final opening/closing phase slow-down speeds.
- «RUN V.» Sets the gate’s opening/closing motion speed.
a
9
ENGLISH
The data and information provided in this manual are to be considered susceptible to change at any time without warning, by CAME cancelli automatici s.p.a.
Activating the radio command
- Connect the antenna’s RG58 cable to the apposite terminals .
- Insert the radio frequency card into the electronic card AFTER DISCONNECTING THE POWER (and disconnecting any batteries).
N.B.: the electronic card picks up the radiofrequency card on when it is running on power.
- Keep pressed the PROG button on the electronic card. The LED will flash.
- Press the button of transmitter to memorise. The LED will stay on to signal memorisation.
Memorisation
c
d
f
e
Settings
- «A.C.T.» Sets the waiting time while open. Once this time has elapsed, closing automatically takes place. The
waiting time may be set from 1 to 150 seconds.
- «PAR.OP.» Sets the gate’s partial opening. By pushing the partial opening button connected at 2-3P, the gate opens
depending on the length of the gate.
- «SLOW S.» Sets the amperometric sensitivity that controls the force generated by the motor during slow down; if the
force exceed the set level, the system intervenes by inverting the direction of motion.
- «RUN S.» Sets the amperometric sensitivity that controls the force generated by the motor during movement; if the
force exceeds the set level, the system intervenes by inverting the direction of motion.
- «SLOW V.» Sets the gate’s final opening/closing phase slow-down speeds.
- «RUN V.» Sets the gate’s opening/closing motion speed.
a

10
ENGLISH
The data and information provided in this manual are to be considered susceptible to change at any time without warning, by CAME cancelli automatici s..p.a.
Disposal
Conformity declaration
This product, including the packaging, is made up of several types of materials that can be recycled.
Investigate the recycling or disposal systems of the product, complying with prevailing local legislation.
Some electronic components may contain polluting substances. Do not litter .
EC DECLARATION OF CONFORMITY
Pursuant to the Low Voltage Directive 73/23/EEC
CAME Cancelli Automatici S.p.A.
via Martiri della Libertà, 15
31030 Dosson di Casier - Treviso - ITALY
tel (+39) 0422 4940 - fax (+39) 0422 4941
Declares under its own responsibility that the equipments for automatic garage doors and gates listed below:
… comply with the National Law related to the following European Directives and to the applicable parts of the
following Standards.
73/23/EEC - 93/68/EC LOW VOLTAGE DIRECTIVE
89/336/EEC - 92/31/EEC ELECTROMAGNETIC COMPATIBILITY DIRECTIVE
EN 60335-1 EN 61000-6-2
EN 13241-1 EN 61000-6-3
IMPORTANT WARNING!
Do not use the equipment specified here above, before completing the full installation. In full compliance to the
Low Voltage Directive 73/23/EEC
THE MANAGING DIRECTOR
Andrea Menuzzo
ZN2
Reference code to request a true copy of the original: DDF L EN Z001a
10
ENGLISH
The data and information provided in this manual are to be considered susceptible to change at any time without warning, by CAME cancelli automatici s..p.a.
Disposal
Conformity declaration
This product, including the packaging, is made up of several types of materials that can be recycled.
Investigate the recycling or disposal systems of the product, complying with prevailing local legislation.
Some electronic components may contain polluting substances. Do not litter .
EC DECLARATION OF CONFORMITY
Pursuant to the Low Voltage Directive 73/23/EEC
CAME Cancelli Automatici S.p.A.
via Martiri della Libertà, 15
31030 Dosson di Casier - Treviso - ITALY
tel (+39) 0422 4940 - fax (+39) 0422 4941
Declares under its own responsibility that the equipments for automatic garage doors and gates listed below:
… comply with the National Law related to the following European Directives and to the applicable parts of the
following Standards.
73/23/EEC - 93/68/EC LOW VOLTAGE DIRECTIVE
89/336/EEC - 92/31/EEC ELECTROMAGNETIC COMPATIBILITY DIRECTIVE
EN 60335-1 EN 61000-6-2
EN 13241-1 EN 61000-6-3
IMPORTANT WARNING!
Do not use the equipment specified here above, before completing the full installation. In full compliance to the
Low Voltage Directive 73/23/EEC
THE MANAGING DIRECTOR
Andrea Menuzzo
ZN2
Reference code to request a true copy of the original: DDF L EN Z001a
Other manuals for ZN2
1
Table of contents
Other CAME Controllers manuals
Popular Controllers manuals by other brands

Emerson
Emerson Bettis SCE300 Installation, operation and maintenance manual

Nordson
Nordson Pro-Flo Operator card

Moeller
Moeller ps4-201-mm1 Hardware and engineering

MRMC
MRMC MIMIC HRNDWHEELS quick start guide

Lincoln Electric
Lincoln Electric MAXsa 10 Operator's manual

Interroll
Interroll MultiControl Operating and programming manual