General warnings.
•The following information must be read and understood before proceeding with the installation, commissioning and maintenance of
the devices described in this document.
•ATTENTION! Any omission or failure to follow these instructions scrupulously can cause danger.
•ATTENTION! Explosion hazard. In case of batteries substitution, make sure that the type is compatible and complies with the
specifications indicated by the manufacturer.
•In case of batteries substitution, DO NOT disconnect the flat cable which connect the electronic boards without removing batteries
before
•ALWAYS substitute all the batteries, also in case of one single battery exhausted.
•If the device is powered by a fixed network, make sure you have disconnected the power supply before carrying out any type of
intervention. Failure to comply with this indication can cause damage to people and/or property.
•Follow the manufacturer's suggested warm-up time (
time required to obtain a reliable measurement
) of the transducer.
•Follow the manufacturer's suggested electric wiring of the transducer to measure (
ground shields at a single point, cable length and
section
); voltage measures on distances exceed 15/20 meters are subjected to electromagnetic disturbances. 0÷25mA inputs have a
superior electromagnetic compatibility (
EMC
).
•Avoid passage in cavities with power or high voltage cables.
•The protection and safety measures and the warranty provided by the Manufacturer with the equipment may be compromised if it’s
used in a manner that does not comply with this user manual.
•This equipment complies with CE regulations.
•Modifications or tampering not expressly approved by the Manufacturer could void the user's authorization to operate the equipment.
•This equipment must be installed by qualified personnel and in accordance with national regulations and/or related local requirements.
•Make sure that the object is properly fixed to supports/infrastructures capable of withstanding this load. Make sure proper methods
and materials are used when fixing the equipment to a wall.
•Only personnel expressly authorized by the manufacturer can open the container. There are no user serviceable parts inside.
1. Description.
The WSD00THCOP is a datalogger designed to measure 4 input channels to acquire indoor temperature [
°C
], relative humidity [
%rel
], CO2
concentration [
ppm
] and atmospheric pressure [
mbar
], with storage functionality of samples
acquired.
2. LED warning function.
The device is equipped, on the front side, with a high performance led (
two flashes every 5 seconds
)
to warn in case of thresholds passing.
Warning persists for the whole duration of the threshold passing condition, so until a new
measure is performed.
The led warning function can be excluded through onboard dipswitches or disabling all threshold
previously configured.
3. BUZZER warning function.
The device is equipped with a buzzer capable to emit a high intensity acoustic signal (
two beeps every 5 seconds
) to warn in case of thresholds
passing.
Warning persists for the whole duration of the threshold passing condition, so until a new measure is performed.
The acoustic signal function can be excluded through onboard dipswitches or disabling all threshold previously configured.
4. Threshold passing - Led and buzzer activation.
The threshold passing condition causes the led and buzzer activation. This condition includes the occurrence of any passing of the configured
values on any channel and in any passing direction (maximum or minimum).
In case of double threshold in the same direction, the activation will be performed for the worst condition.
To inhibit the warning function, working on thresholds is sufficient. These are normally disabled, but can be activated and configured in values,
working in any time on system configuration through software and/or through web.
Warning function can be excluded also electrically, working on dip-switches position located on electronic pcb, referring to the following table: