Carefree of Colorado Service Manual PARAMOUNT
052548-301r1 13
D03 ONE AWNING DOES NOT OPERATE
NOTE: The awnings are programmed sequentially (i.e. #1, #2, #3, #4). If power is missing from an awning, the
subsequent awnings will not function (i.e. #1 and #2 works, #3 and #4 don't). Check the power to the first non
functioning control board in sequence (i.e. #3) and correct as necessary before proceeding.
YES Awning functions, control board of non-
working awning is defective – replace
control box.
A 1. Shut off power source if not already done.
2. Open control boxes and disconnect the non-working
awning motor wires and a working awning's motor wires.
3. Connect the non-operating awning to the functioning
control board (i.e. awning #2 to control board #1).
4. Restore power
5. Test the operation of the awning using the controls for
the functioning awning (in the example above #1
awning).
NO Return wires to original configuration.
Go to step B
B Confirm awning motor is functioning
YES Awning motor is good, control box is
defective - replace
1. 1.1 With power off, connect awning motor directly to
110VAC power source.
White = Hot
Green = Ground
Red & Black are Motor Direction Control – connect
one
1.2 Briefly apply power.
1.3 Does awning move when power is applied?
NO Go to step B-2
YES Continuity is good, motor is defective –
replace
2. Test continuity and connections of motor wire between
control box and awning motor.
NO Repair as required and retest
D04 AWNING(S)DO NOT RETRACT DURING WINDY CONDITIONS
The Direct Response auto-retract system operates by gauging the motion of the awning's leading edge, not by the
direct wind speed. Refer to the description in the owner's manual.
NOTE: The awnings have independent sensors and may not retract concurrently.
YES The flashing LED indicate that the
sensor(s) have been disengaged or
other wise disabled. Go to step C
A Press the power on button then press the auto-retract button.
Does the indicator LED flash (slow pulse)?
NO Go to test B
YES Operation is normal, Go to step C
B Confirm standard awning operation. From the key pad,
operate the awnings. NO Refer to the appropriate test D02 or
D03
YES The affected awning retracts. Original
sensor is defective replace.
Return second shaker to the unaffected
awning controller.
C Check function of shaker sensor
1. Open the affected awning (does not have to be open all
the way).
2. Open the second awning.
3. Open control box and disconnect sensor from controller
board of awning that does not auto-retract.
4. If cable has been spliced between sensor and control
box, check continuity of splice. Repair as required and
retest before proceeding.
5. Disconnect the sensor from the other controller and plug
the cable into the "SHAKE" terminal of the affected
awning controller.
6. At key pad, turn power ON and auto-retract ON.
7. Set auto-retract to the lowest setting.
8. At the unaffected awning, create a firm but gentle
rocking motion with the leading edge of the awning for
about 3-4 seconds.
NO Awning does not retract, control box is
defective – replace
NOTE: The key pad LEDs will continue to flash after connecting good sensors. It is necessary to power off the
system then turn it back on so that the key pad recognizes the sensors are connected