CAS AP Plus-MX User manual

2

3
CONTENTS
PRECAUTIONS....................................................................4
PREFACE.................................................................................6
INSTALLATION.....................................................................6
NAMES AND FUNCTIONS............................................7
OPERATION.........................................................................12
1. Simple weighing..............................................................12
2. Weighing with Tare.........................................................12
3.Adding up transactions for weighed commodities......13
4.Adding up transactions for non-weighed.....................15
(Fixed Price) commodities
5. Canceling daily total transaction...................................16
6. Calling up & clearing up previous total price................17
7. Making payment.............................................................18
8. Discount on total sales amount.....................................19
9. Saving PLUs' (Price Look-Up) unit price .....................20
10. Calling up a PLU...........................................................24
11. Displaying total sales....................................................26
OPTION
1. Saving Euro rate.............................................................28
2. Switching currency.........................................................29
3.Selecting the printer........................................................30
4. Setting-up printing ticket (receipt) format .....................31
ASCII CODE..........................................................................37
ERROR MESSAGES.......................................................38
SPECIFICATIONS.............................................................39

4
PRECAUTIONS

5
PRECAUTIONS

6
PREFACE
Thank you for the purchasing of our CAS AP PLUS Series.
This series have been designed with CAS reliability, under rigid quality control
and with outstanding performances. Your speciality departments can enjoy with
these high quality reliable CAS products.
We believe that your needs will be satisfied and you will have proper reliability
in variable weight.
This manual will help you with proper operations and care of the AP PLUS series.
Please keep it handy for the future references.
INSTALLATIONS
Put a post pipe into a post bracket as Fig. -1
Screw the post bracket and the post pipe as Fig. -2

7
NAMES AND FUNCTIONS
OVERALL VIEW
DISPLAY & KEYBOARD
1. AP PLUS-EX Type

8
2. AP PLUS-MX Type
3. AP PLUS-M Type
4-1. AP PLUS -EC Type(Symbol Type)
4-2. AP PLUS -EC Type(Standard Type)

9
5-1. AP PLUS -Euro (AP PLUS -EX Type)
5-2. AP PLUS -Euro (AP PLUS -EC Type)
5-3. AP PLUS -Euro (AP PLUS -M Type)

10
■KEY FUNCTIONS
KEY FUNCTIONS
Used to enter all the numeric data.
Used to enter a double zeros.
Used to clear all the numerics on the unit price display.
Used to clear sum total price.
Used to clear all the daily total prices.
Used to move to next byte when inputting ASCII code.
Used to correct the zero point.
Used to move to previous byte when inputting ASCII code.
Used to move to user set-up mode.
Used to enter a tare weight.
Used to delete a tare weight.
Used to move to next printing ticket format setting mode when
inputting ASCII code.

11
NAMES AND FUNCTIONS
KEY FUNCTIONS
Turns on and off the displays.
Used to add up a fixed price item.(non weighed)
Used to add up a weighed item.
Used to calculate a change.
Used to cancel a prior accumulation.
Direct PLU(Price Look Up) keys.
Used to check the all displays.
Used to call a total price of add up transactions.
Used to convert the modes.
A default is weight mode after the power on.
Used to call an indirect PLU(Price Look Up) in memory.
Used to save a PLU(Price Look Up) to memory.
Used to finalize sales transaction.
Direct PLU keys.
Used to set Euro to local currency, and vice versa.

12
OPERATIONS
1. Simple Weighing Mode
Enter an unit price.①
②Place the commodity on
the platter.
③Remove the commodity
from the platter.Press "C" key to
clear unit price input.
NOTE▶: Automatic unit price clearing function may not be applied to
all of AP PLUS series
2. Weighing with Tare
■The tare is the weight of a container being used for a commodity.
■The tare key subtracts the weight of the container.
①Place the container on the
platter.
②Press TARE key. ③Enter an unit price.

13
④Place the commodity on
the platter.
⑤Remove the commodity from the platter.Press "C"
key to clear previous transaction.
NOTE: To remove TARE function press "TARE" key again after removing the▶
container from the platter. Automatic tare clearing function may not be applied to
all of AP PLUS series.
3. Adding up transactions for weighed commodities
■This add-up function is useful for transaction to purchase several commodities.
■You can check total price by pressing TTP CALL key. And delete total price
data by pressing C key after transaction is completed.
①Enter an unit price.
②Place the commodity on
the platter.
③Press ADD key.

1
4
④Remove the commodity
from the platter.
⑤Enter another unit price. ⑥Place the commodity on
the platter.
⑦Press ADD key.
⑧Remove the commodity
from the platter.
⑨Press TTP CALL key to call
up total price.
■This function is effective on either that total
number of transactions is up to 1,000 and total
amount of money is up to 9,999.99.
■When input data exceed maximum capacity for
total number of transactions or total amount of
money the scale beeps to notify an error.
⑩Press C key to clear the sum of transaction.

15
4. Adding up transactions fornon-weighed(Fixed price)commodity
This is a function to add up several transactions for non-weighed commodity,
using “FAD(Fixed price Added)” key.
■User should keep the platter empty when he/she tries this function in the beginning.
①Enter a price. ②Press FAD key. ③Enter a next price.
④Press FAD key.Total
amount will be shown on
total price display.
⑤Press FAD key again to exit.

16
5. Canceling daily total transactions
■When user makes more than two sales transactions he/she can cancel previous mistake transaction(s)
of them by doing “Cancel” function.
①Press numeric keys to input
a unit price.
Ex) Item’s unit price=2.00
②Press FAD key and
appropriate numeric keys to
make next another sales
transaction.
Ex) unit price = 1.99, 1kg
③Place item on the platter and
do ADD function.
Ex) unit price=1.99, 1kg
Remove it from the platter.
④To cancel previous
transaction input the same unit
price and place the same item
on the platter. Then, press CAN
key.
Remove it from the platter.
●Remove the item from the platter. For sure user may check total number of a series of transactions after
canceling previous one by pressing ttp call key to call up “ttP(Total Price)”.

1
7
■User can call up previous total price simply by pressing “TTP CALL” key.
■User can clear the sum of transactions simply by pressing “C” key.
■This function is effective on either that total number of transactions is up to 1,000
or total amount of money is up to 99,999.99.
■When input data exceed maximum capacity for above total number of transactions
or total amount of money the scale beeps to notify an error.
6. Calling up & clearing up previous total price
■Calling up total price
①Press TTP CALL key. ②Press TTP CALL key again to exit.
■Clearing up total price data
①Press TTP CALL key. ②Press C key. This function will clear
up total price data permenatly.

1
8
7. Making Payment
This is the function to make payment or change on the scale. The payment function
is effective only if the amount customer pays exceeds the amount of total price.
①Press TTP CALL key. ②Press PAY key, assuming
total amount is 26.33
③Enter a customer's payment.
The payment will be displayed
on the unit price display.
Press PAY key.
④Press PAY key again to
show the amount of change.
⑤Press PAY key to exit.

19
8. Discount on total sales amount
①Press TTP CALL key just to
check total amount.
Ex)Total amount=115.00,
Total number of transaction=5.
②Press CAN key.
③Press appropriate numeric
keys to input the amount of
discount.
④Press CAN key.
●Press SUM key to finalize these transactions. (Refer to the “making payment” function on page 17).

20
9. Saving PLUs (Price Look-Up)
This is the function to save PLUs to memory in the scale. PLU means
“Price Look-Up” which includes individual unit price information.
■AP PLUS series have different PLU memory capacity, depending on the product
model.
■There are two different kind of PLUs, direct and indirect PLU.
- Direct PLU: User can call up PLU directly by pressing preset keys, for
example, any key of M1~M7 or any key of 28 keyboard.
- Indirect PLU: User can call up any one of PLUs with designated numbers
by pressing the designated numeric key(s), for example, "4" and "5"
numeric keys for PLU # 45.
■Maximum PLUs Memory Capacity
Product Model Direct PLUs Indirect PLUs
AP PLUS-EX Up to 28 PLUs Up to 200 PLUs
AP PLUS-MX Up to 5 PLUs Up to 200 PLUs
AP PLUS-M Up to 7 PLUs Up to 200 PLUs
AP PLUS-EC Up to 28 PLUs
EC type Up to 27 PLUs
EX type Up to 27 PLUs Up to 200 PLUs
AP PLUS
(EURO)
Version M type Up to 6 PLUs
A) Direct PLUs
①Enter an unit price. ②Press MW key. ③Press one of direct PLU
keys. The display automatically
goes to save valid data set on
PLU mode.
(Described on page 21.)

21
B) Indirect PLUs
①Enter an unit price. ②Press MW key. ③Enter a desired number(s)
to store a PLU(s) at a
specific address(es). You
can select any number
within the indirect PLU
memory capacity.
④Press MW key to save it.
The display automatically
goes to save valid data set on
PLU mode.
(Described on page 21.)
This manual suits for next models
4
Table of contents
Other CAS Scale manuals