CAS IE-1700 User manual

2005. 6
IE-1700
Electronic Crane Scale
OWNER’S MANUAL

CONTENTS
Safety guide 4
Precaution 4
Product characteristics 4
Specification 5
Model 6
Size and net weight 6
Operation 7
Electrical Principle Diagram 9
Display Message 10
Troubleshooting 11
Remote controller 12

Standard GB/T11883-2002 Electrical Crane Scale
Accuracy class OIML class III
Display 30mm(1.2 ") 5digits LCD/LED
Zero Range 4% full capacity
Tare Range 100% Full capacity
Stable Time 10 seconds
Overload Indication 100% Max. capacity 9e
Max. Safety Load 125% Max. capacity
Ultimate Load 400% Max. capacity
Battery Life 50 hours
Battery Type Fully sealed Lead-Acid battery, 6V/5Ah
Adapter DC9V/1500mA
Operating Temp. 10 ~ 40
Operating Humidity 85% RH under 20
Remote Controller Distance Min. 10m
Battery of Remote Controller 5# battery, 1.5V x 2
5
4
Safety Guide
Specification
Product Characteristics
Over-loading this scale is harshly prohibited
Refrain from long-time loading that could lead to excessive fatigue on loadcell
used inside the scale. Excessive fatigue on loadcell would decrease the
accuracy and shorten the life of scale.
Check the shackle and hook regularly.
Check the battery power level before/after use and recharge the scale in time.
In order to maximize the battery life, periodic recharging is necessary for
scales even not in use for long time.
Do not try to repair the scale by yourselves.
Use privately attached charger only.
High quality: The process management is operated according to OIML R76,
GB/T11883-2002, and get the European CE certificate.
Safty installation: Aluminum Die-Casting Case, high intensity hook and
shackle, special loadcell for safty installation.
High reliability: Using high quality components on PCB circul board to insure
long time stability.
Broad applicability: 30mm high character display, 25M distance eyeshot, can
be used in storage industry, textile industry, metallurgy industry etc.
Simply operation: Check battery voltage automatically, wireless remote
controller, separate battery space, small volume, easy to bring.
Complete function: Kg/Lb conversion, Hold, Tare, Division choice,Stablity
regulation, Accumulation/Search, Gross/Net conversion, parameter
regulation etc.
Read carefully the following instruction and advice before using this scale.
Model Display Characteristics
IE-1700 30mm(1.2 ")LED High accuracy,small volume,
30mm(1.2 ")LCD easy to bring.
Precaution
The crane scale is a kind of precise weighing instrument, pay attention
on operation and maintenance.
Rotate the load instead of machine itself if necessary for operation.
Stop using the machine under the circumstances of thunder & rain.
Check periodicly if the clips/pins and screws of the machine are loose or
broken before use.
If low battery signal appears & LED annunciator goes green while
charging, please check the battery.
Hang the machine instead for storage while not in use in order to prevent
from unnecessary load on the weight sensor inside.
Do not subject the scale to sudden temperature changes.
Avoid from the shock of extreme excessive weight.

7
6
Size and net weight
Operation
Notice : If there's any modification, all the date are subject to the scale itself.
Notice : To guarantee the accuracy, leave scale alone for 3~5 minutes after turning on.
Max.Capacity L A B C Net
(mm) (mm) (mm) (mm) weight
100kg 335 20 65 20 4.0
200kg 335 20 65 20 4.0
300kg 335 20 65 20 4.0
500kg 360 25 75 20 4.2
1000kg 360 25 75 20 4.2
Operation Display Illustration
OFF/ON Display two times
Display capacity two times
.Display the voltage of battery
Wait stable signal
"STB" light, can hang the weight
TURN ON
ZERO
Operation Display Illustration
Press 0 on scale After turn on, generally display
Press ZERO on if not for
controlller can operate like this
TARE
Operation Display Illustration
Press T on scale Press this key to deduct the weight of
Press TARE on container,while “TARE” light on, the
controlller scale will show the net weight of load
Notice: As crane scale deduct the weight of container automatically,so it will
show the net weight of load every time, you needn’t press this key to get net
weight until you change the container or turn off.
Model
Model Max. capacity Min. capacity Division Total display
(kg/lb) (kg/lb) (kg/lb) (kg/lb)
IE -1700 - 01 100/220 1 /2 0.05 /0.1 n=2000
IE -1700 - 02 200/500 2 /4 0.1 /0.2 n=2000
IE -1700 - 03 300/700 2 /4 0.1 /0.2 n=3000
IE -1700 - 05 500/1100 4 /10 0.2 /0.5 n=2500
IE -1700 - 1 1000/2200 10 /20 0.5 /1 n=2000
OVERLOAD WARNING
The display will show once the load (Net + Tare) exceeds Max. capacity.
Make sure that the load are within the capacity range, otherwise it’s very
dangerous.

9
8
POWER SAVING
The display will show when the load are at stable status in excess of 15
minutes and revert to normal weighing readings while load changes. when the
load are at stable status in excess of 60 minutes, the scale will turn off
automatically
RECHARGING BATTERY
1. Turn off, connect the adapter with 220V AC power supply , also insert the
plug in the socket which located in the rear of scale. The light become green,
it means it’s recharging automatically, until the green light become red, that
means recharging is finished.
2. When you need to use crane scale hour after hour, take off the rear cover,
change the battery with recharged battery.
Attention: Generally, the time of recharging should not lower than 8 hours, this
scale have recharging protection function, long time recharging will not damage
the battery.
TURN OFF
Press OFF/ON on scale 2 seconds
Press OFF on controller 2 seconds
Stable after 15minutes, it show , after 60minutes,it turn off automatically.
Electrical Principle Diagram
Control
distance
Control key
Battery
Load cell signal
enlarges A/D CPU LED or LCD
display
CHECK BATTERY
Press OFF/ON on scale, when turn on or turn off,it shows
Press OFF on controller, when turn off, it shows
Press MR F1 , it shows , press MR return
HOLD THE WEIGHT READING
Press “ HOLD” key on the remote controller to hold the displayed weight reading.
At this moment, “ HOLD” light on, Press this key again will disable hold
function.
LOW BATTERY WARNING
When the battery voltage lower than , the display flash, but the
scale can still work until the display show , one minute later,
it will turn off automatically, you need to recharge the battery to use again.

11
10
Reason
Battery damaged
Battery contact loosed
Low battery Min. Capacity
OFF/ON Åbuttun damaged
TARE Åbuttun damaged
The recharger damaged
The recharger isn’t
plugged ready
The load is unstable
Loadcell cable damaged
The scale in damp
environment for a long time
No enough time for heating
the scale after turn on
Put the scale on ground for
too long time
The scale isn’t hung properly
Battery damaged
Outlet damaged
Receiver window is too dirty
low battery of controller
Solution
Check battery
Tighten the contact
Recharge the battery
Check&clean the buttun
Check&clean the buttun
Check the recharger
Insert plug again
Stablize the load
Check and replace loadcell
Put the scale in dry
environment
After turning on, heating 3-5
minutes.
Scale should be hung
Check the scale and sling
Replace battery
Replace the outlet
Check and clean
Replace controller battery
Troubleshooting
Phenomenon
No display when
turn on
Display flash
Can’t trun on &off
Can’t tare
Recharge indicator
light can’t turn on
Display isn’t stable
The display don’t show
“0” when empty load
The error is large
Battery can’t recharge
Remote distance shorten
Illustration
Waiting stable
Accumulated weight not exceed Min. Capacity
Accumumated times exceed, (can’t accumulate after 30times)
Accumulated weight exceed(can’t accumulate after 99999)
Ask if you really want to delete accumulated weight, in case
error deletion
Give up deletion
Confirm deletion
No any accumulated value (when you check)
Conversion, when you press SHIFt in controller
The voltage of current battery
Enter weight adjustment
Enter parameter adjustment
Enter voltage adjustment
Overload warning
Low battery warning
End, when parameter adjustment ready
Turn off
Display Message
Display

13
12
TARE
1. Tare directly
Operation Illustration
TARE Display show net weight, “TARE” light on
TARE Display show gross weight, “TARE” light off
2. Set tare weight in advance
Attention: After display two times circlely, it will return to weigh situation
automatically, you also can press MR to return directly.
Operation Display Illustration
MR
TARE Current tare weight
Input the tare weight
Exit, “TARE” light on, it will deduct tare weight
MR automatically when weighing.
ACCUMULATION
Operation Display Illustration
MCurrent accumulation times
Rear four digit of current accumulated value
Front four digit of current accumulated value
SEARCH
Operation Display Illustration
MR Current accumulation times
MCurrent weight
Rear four digit of current accumulated value
Front four digit of current accumulated value
MR Return to weigh
Remote controller guide
Lightness of display
Operation Illustration
F1 0~5, 0: no display, 1: Minimum light, 5: Maxium light
(Default: 2)
HOLD
Operation Illustration
HOLD Hold the weight, “HOLD” light on
HOLD Convert to weighing situation, “HOLD” light off
ZERO
Operation Illustration
ZERO display when no load, “ZERO”light on
Attention: Press TARE and 0 can search every time weight and
accumulated value,press MR return.
CLEAR
Operation Display Illustration
CLEAR Display blink, please confirm if you
want to delete accumulated value
CLEAR Cancel deletion
MR Confirm deletion
ZERO DISPLAY
Operation Display Illustration
MR
ZERO Display current zero value

14
TURN OFF
Operation Display Illustration
OFF
Display show current voltage of battery
then turn off
Kg/Lb conversion
Operation Display Illustration
MR Un=0:kg “lb”light off
HOLD Un=1:lb “lb” light on,
SEARCH OVERLOAD TIMES
Operation Display Illustration
MR
CLEAR Display times of overload
VOLTAGE DISPLAY
Operation Display Illustration
MR
F1 Display show current voltage of the battery
MR Return to weigh
MEMO

18
MEMO
Table of contents
Other CAS Scale manuals

CAS
CAS TP-15 User manual

CAS
CAS PR2-15 User manual

CAS
CAS LP-II Installation and maintenance instructions

CAS
CAS BF-1255 User manual

CAS
CAS PD-II User manual

CAS
CAS SW-1S Series User manual

CAS
CAS Retail PR-T Series User manual

CAS
CAS ERII-6 User manual

CAS
CAS CL5200J Series User manual

CAS
CAS LP-1000N Series User manual