Receiver type: Supereheterodyne.
Demodulation: AM/ASK.
Operating frequency: 433.92 Mhz.
Sensitivity ( for good signal ): -115 dBm.
Input load: 50 Ohm.
Power supply : 230 Vac - 50 Hz.
Current consumption 10 mA @230 Vac
Relay contacts NO/NC.
Max current on relay output: 16 A.
Memory capacity: 500 transmitters
Security protocol Keeloq® Hopping code
N° of code combinations 2exp64
Operating temperature: from -20 to +70 °C.
Overall dimensions ( Fig. 2): 123 x 81,5 x 41,5 mm
Weight: 65 gr.
Relay operating mode Pulse, step, timed, on-off
Delay from 1 sec. to 24h: 59 min.
Enclosure protection IP55
The receiver Erone type SEL2641R433-XPL1V ( Fig. 1) is a AM/ASK single conversion
superheterodyne receiver with integrated “Keeloq® Hopping code” decryption.
A special algorithm allows to keep synchronyzed transmitter and receiver.
Power supply : 230 Vac.
The receiver relay output, can drive many type of loads, up to 16A / 230 Vac.
It’s advised to drive locks, magnets, and any type of power load.
The transmitter memorization can be carried out either with 2 push-buttons of the receiver
or remotely, using only the keys of the transmitter. The setup of the remaining parameters
can be done only with the 2 push buttons of the receiver. All the setting steps are displayed
by a backlit LCD display.
The internal data can be saved/restored to/from an external memory.
1 RELAY RECEIVER SEL2641R433-XPL1V
2Technical Specications
3Mounting
www.erone.com - www.cdvigroup.com
Fig.1
1Introduction
Option B ) Use of PG7 cable glands
( not provided )
Drill the placing surface
with ø6 mm tool and insert the
2 plugs
Then x the support with
the screws provided
F1001000089
Fig. 3
Fig. 2
Fig. 1
ERONE
XPL1V
ERONE
XPL1V
ERONE
XPL1V
123
81,5 41,5

Fabricant de Contrôle d’Accès depuis 1985 Manufacturing Access Control since 1985
The installer’s choice
4Layout & Wiring
Erone - S2TR2641E2-E4-E2M
Erone SETR2641AM1, SETR2641AM2
Erone S3TR2641T1-T2-T4
Erone SETR2641TM
Erone S7TR2641E4
Erone FKT2641E1 - FKTHS2641E1
CDVI GALEOR
The receiver allocation is very important for the best operation of the
system. Place the receiver far from interference sources such as big
magnetic elds or radio emissions. The installation and the positioning of
the antenna is very important as well. Before installing the antenna it is
advisable to make some tests on the site.
The distance between 2 receivers must be at least 1,5m.
The appliance full complies with the requirements of the following
European Directives : 2006/95/CE, 2004/108/CE, 99/05/CE and the
Standard EN 60335-1.
5Compatible transmitters
6Warnings
7Display Legend
There are 2 methods available:
1) Using P1 and P2 throughout the menu
2) Remote from the receiver, using a transmitter already in the receivers
memory (Mode PLUS ).
P1 : enter the menu ( 4 sec.)
or
conrm the choice
P2 : navigate
the menu
8Programming / Navigation menu
Button activated TX Serial number
Relay activated
The factory value for the timing is
1 sec. Use P1 to scroll the digits
and P2 to conrm
Relay 1 : Pulse Relay 1 : Step Relay 1 : Timed
Menu
Timed
Add: Add transmitters s/n
Delete TX : Delete a single transmitter, the button of a transmitter, a transmitter
from a list , all transmitters Reset to factory default
Info relay : Display relay operating mode, the number of Tx memorized, the of
Transmitters, the SW release.
Cong relay
Set relay operating mode ( pulse , step, timed , On/Off)
Set delay time of relay
Backup to : data backup to an external memory
Restore from : data restore from an external memory
Plus ON : Enable remote transmitter memorization
Plus Limited : Enable remote transmitter memorization only using a TX «master»
( see chapter 12 )
Plus OFF : disable remote transmitter memorization
Connector for
backup memory
Backlit
LCD Display
Buzzer
ERONE
XPL1V
www.erone.com - www.cdvigroup.com
Fig. 5
ERONE
XPL1V
Fig. 4
Antenna
RG58
NC NO
C
L
N
230 Vac
P1
P2

Fabricant de Contrôle d’Accès depuis 1985 Manufacturing Access Control since 1985
The installer’s choice
www.erone.com - www.cdvigroup.com
9Menu Add
(*) NOTE : The rst TX added acts as Master: that means that it can be used to add more tx using the PLUS option.
The submenu Add Master allows to assign the Master property to any other TX already in memory even not memorized on the rst position.
Once a TX has been assigned as Master, its property cannot be removed unless to delete it from the memory using the Delete menu.
The transmitters «Master» are identied with the «#» in the list.
Push TX
Button
Enter the number
of TX [1 < n < 500]
Press the transmitter buttons
which activate Relay 1 and
press P1 to conrm
Example: Relay 1 of the full block
will be activated by buttons A
and C
Push Button of the TX
to store as Master (*)
Push Button
of the rst TX
Block memorization
10 Menu Cong
Allows to set the operating mode of the relay as Pulse, Step,Timed or ON/OFF In case of Timed it’s possible to set the delay time from 1 sec.
to 24h: 59 min.
PULSE : the relay stays excited as long as the transmitter is
activated.
ON-OFF : the relay excites if it is pressed the button A of the
TX and releases when it is pressed the button B. It is enough to
memorize only the button A : the button B automatically releases
the relay.
If the transmitter is a 4-button type, it’s possible to get A=ON ,
B=OFF and C=ON, D=OFF memorizing only the buttons A and C.
WARNING : if you memorize only the buttons B or D the function
ON-OFF doesn’t work
STEP : the relay excites at the rst transmission and releases at
the next transmission of the same button of the remote control.
TIMED : the relay excites at the rst transmission and releases
after the delay programmed. Set the desired delay time using P2
to scroll the digits and P1 to conrm and shift to next : the time is
expressed in hours , minutes and seconds.

GUARANTEE
The warranty period for this product is 60 months, beginning from the manufacturer date. During this period, if the product does not
work correctly, due to a defective component, the product will be repaired or substituted at our discretion. The guarantee does not
cover the plastic container integrity. After-sale service is supplied at the factory.
Fabricant de Contrôle d’Accès depuis 1985 Manufacturing Access Control since 1985
The installer’s choice
14 Memorization Plus
13 Backup / Restore
(*) : Push the button of the new
transmitter before the end of
the beep.
NOTE : If the option «PLUS LIMITED» is set, the transmitter which «opens» the memorization can be only the rst transmitter memorized.
If the option PLUS is OFF the remote memorization is disabled.
If the option PLUS is ON the remote memorization of a new transmitter can be done using any transmitter already in memory.
The memorization PLUS is active only if there is, at least, one transmitter in the memory. When the memory is empty, the memorization of the rst
transmitter can be effected only using the buttons P1 and P2.
!(*) Attention : this operation will overwrite all data of the internal memory
Manufactured by : CDVI Wireless SPA - Via Piave, 23 - 31020 S.Pietro di Feletto (TV) - Italy
Tel : +39-0438-450860 - Fax : +39-0438-455628
External
Internal
External
Internal
Save
Restore (*)
MEM.
MEM.
MEM.
MEM.
Allows to create a backup of the memory data-base and save it onto an external
memory ( type SEL2641-MXPL) ( g. 6)
Plug-in the memory in the proper receiver connector
The memorization PLUS allows to add a new transmitter remotely, without using the push-buttons P1 & P2. It’s enough to use a transmitter «Ma-
ster».
A transmitter «Master» can be :
1) the rst transmitter added;
2) any transmitter memorized and changed as «master» using the Add Master submenu ;
The PLUS feature can be : ON, Limited or OFF
• Plus ON : remote transmitter memorization enabled;
• Plus Limited : remote transmitter memorization enabled only using a TX «master» ( see g. 7 );
• Plus OFF : remote transmitter memorization disabled;
Fig. 6
11 Menu Delete
12 Menu Info
Delete TX : Delete a transmitter. It’s necessary to have the transmitter available because the
system requires the RF transmission;
Delete Button : Delete the single button of a transmitter;
Delete by List : Delete a transmitter from a list. In this case it is enough to know the S/N of the transmitter
to be deleted to nalize the cancellation;
Delete All TX : Delete all transmitters;
Delete setting : Reset to factory default: delete all the transmitters and reset the relay operating mode
to PULSE.
For all the options, use P2 to scroll and P1 to conrm
Info relay : Display relay operating mode
Info N. Users : Display number of Tx memorized
Info List : List of Transmitters
Info Version : SW release.
For all the options, use P2 to scroll and P1 to conrm
ERONE
XPL1V
Fig.7
Other CDVI Receiver manuals

CDVI
CDVI SELWR433-SAT User manual

CDVI
CDVI RADIUM WRW User manual

CDVI
CDVI SEL2641R433-XPL4P User manual

CDVI
CDVI SEL2641R433-XPL User manual

CDVI
CDVI SEL2641R433-IP User manual

CDVI
CDVI DIGITAG-LR User manual

CDVI
CDVI SEL2641R433-XPL2P User manual

CDVI
CDVI SEL128R433-WPL User guide

CDVI
CDVI DIGITAG-LR DTRR1434R User manual

CDVI
CDVI ERONE SEL2641R433-XPL4V User manual
Popular Receiver manuals by other brands

Pioneer
Pioneer VSX-1015TX-S Service manual

Extron electronics
Extron electronics Dual Link DVI Transmitter and Receiver DVI DL 201... Setup guide

Sony
Sony MRD-D1 installation manual

Philips
Philips FR 731 Brugsanvisning

Opticum
Opticum ACTUS MINI user manual

Lectrosonics
Lectrosonics UDR700 quick start guide