Fabricant de Contrôle d’Accès depuis 1985 Manufacturing Access Control since 1985
The installer’s choice
Receiver type: Supereheterodyne.
Demodulation: AM/ASK.
Operating frequency: 433.92 Mhz.
Sensitivity (for good signal): -115 dBm.
Input load: 50 Ohm.
Power supply: 12/24 Vac/dc
Current consumption: 130 mA @ 12 Vdc,
90 mA @ 24 Vdc
Relay contacts 2 x NO/NC.
Max current on relay output: 16 A.
Memory capacity: 500 transmitters
Security protocol Keeloq® Hopping code
N° of code combinations 264
Operating temperature: from -20 to +70 °C.
Overall dimensions (Fig. 2): 155 x 118 x 56 mm
Weight: 115 gr.
Relay operating mode Pulse, step, timed, on-o󰀨
Delay from 1 sec. to 24h: 59 min.
Enclosure protection IP55
The receiver Erone type SEL2641R433-XPL2P (Fig. 1) is a AM/ASK single conversion
superheterodyne receiver with integrated “Keeloq® Hopping code” decryption.
A special algorithm allows to keep synchronyzed transmitter and receiver.
Power supply: 12/24 Vac/dc. 2 power relay outputs.
The receiver relays output, can drive many type of loads, up to 16A / 230 Vac.
The transmitter memorization can be carried out either with 2 push-buttons of the receiver
or remotely, using only the keys of the transmitter. The setup of the remaining parameters
can be done only with the 2 push buttons of the receiver. All the setting steps are displayed
by a backlit LCD display.
The internal data can be saved/restored to/from an external memory.
2 RELAYS RECEIVER SEL2641R433-XPL2P
2Technical Specications
3Mounting
www.erone.com - www.cdvigroup.com
Fig.1
1Introduction
Drill the placing surface
with ø6 mm tool and insert the
2 plugs
Then x the support with
the screws provided
F1001000091
Fig. 3
Fig. 2
Fig. 1
ERONE
XPL2V
118
155 56
4 x PG11 + 1 PG7 cable
glands ( provided )
ERONE
XPL2P
Fabricant de Contrôle d’Accès depuis 1985 Manufacturing Access Control since 1985
The installer’s choice
4Layout & Wiring
Erone - S2TR2641E2-E4-E2M
Erone SETR2641AM1, SETR2641AM2
Erone S3TR2641T1-T2-T4
Erone SETR2641TM
Erone S7TR2641E4
Erone FKT2641E1 - FKTHS2641E1
CDVI GALEOR
The receiver allocation is very important for the best
operation of the system. Place the receiver far from
interference sources such as big magnetic elds or radio
emissions. The installation and the positioning of the
antenna is very important as well. Before installing the
antenna it is advisable to make some tests on the site.
The distance between 2 antenna must be at least 0.7m.
Hereby, CDVI Wireless Spa, declares that the radio
equipment type SEL2641R433-XPL2P is in compliance
with directive 2014/53/EU. The full text of the EU declaration
of conformity is available at the following internet address:
www.erone.com.
5Compatible transmitters
6Warnings
7Display Legend
There are 2 methods available:
1) Using P1 and P2 throughout the menu
2) Remote from the receiver, using a transmitter already in the receivers
memory (Mode PLUS ).
P1 : enter the menu ( 4 sec.)
or
conrm the choice P2 : navigate
the menu
8Programming / Navigation menu
Button activated TX Serial number
Relay activated
The factory value for the timing is
1 sec. Use P1 to scroll the digits
and P2 to conrm
Relay 1 : Pulse Relay 1 : Step Relay 1 : Timed
Menu
Timed
Add: Add transmitters s/n
Delete TX : Delete a single transmitter, the button of a transmitter, a transmitter
from a list , all transmitters Reset to factory default
Info relay : Display relay operating mode, the number of Tx memorized, the of
Transmitters, the SW release.
Cong relays
Set relay operating mode ( pulse , step, timed , On/O󰀨)
Set delay time of each relay
Backup to : data backup to an external memory
Restore from : data restore from an external memory
Plus ON : Enable remote transmitter memorization
Plus Limited : Enable remote transmitter memorization only using a TX «master»
( see chapter 12 )
Plus OFF : disable remote transmitter memorization
Connector for
backup memory
Backlit
LCD Display
Buzzer
www.erone.com - www.cdvigroup.com
Fig. 5
ERONE
XPL2P
Fig. 4
Antenna
RG58
P2P1
NC
NO
C
R1 R2
Common
K2
K1
NC
NO
C
0
+12-24 Vac/dc
Fabricant de Contrôle d’Accès depuis 1985 Manufacturing Access Control since 1985
The installer’s choice
www.erone.com - www.cdvigroup.com
9Menu Add
(*) NOTE : The rst TX added acts as Master: that means that it can be used to add more tx using the PLUS option.
The submenu Add Master allows to assign the Master property to any other TX already in memory even not memorized on the rst position.
Once a TX has been assigned as Master, its property cannot be removed unless to delete it from the memory using the Delete menu.
The transmitters «Master» are identied with the «#» in the list.
Push TX
Button
Enter the number
of TX [1 < n < 500]
Press the transmitter buttons
which activate Relay 1 and
press P1 to conrm
Example: Relay 1 of the full block
will be activated by buttons A
and C
Push Button of the TX
to store as Master (*)
Push Button
of the rst TX
Block memorization
10 Menu Cong
Allows to set the operating mode of each relay as Pulse, Step,Timed or ON/OFF In case of Timed it’s possible to set the delay time from 1 sec.
to 24h: 59 min.
PULSE : the relay stays excited as long as the transmitter is
activated.
ON-OFF : the relay excites if it is pressed the button A of the
TX and releases when it is pressed the button B. It is enough to
memorize only the button A : the button B automatically releases
the relay.
If the transmitter is a 4-button type, it’s possible to get A=ON ,
B=OFF and C=ON, D=OFF memorizing only the buttons A and C.
WARNING : if you memorize only the buttons B or D the function
ON-OFF doesn’t work
STEP : the relay excites at the rst transmission and releases at
the next transmission of the same button of the remote control.
TIMED : the relay excites at the rst transmission and releases
after the delay programmed. Set the desired delay time using P2
to scroll the digits and P1 to conrm and shift to next : the time is
expressed in hours , minutes and seconds.
GUARANTEE
The warranty period for this product is 24 months, beginning from the manufacturer date. During this period, if the product does not
work correctly, due to a defective component, the product will be repaired or substituted at our discretion. The guarantee does not
cover the plastic container integrity. After-sale service is supplied at the factory.
Fabricant de Contrôle d’Accès depuis 1985 Manufacturing Access Control since 1985
The installer’s choice
14 Memorization Plus
13 Backup / Restore
(*) : Push the button of the new
transmitter before the end of
the beep.
NOTE : If the option «PLUS LIMITED» is set, the transmitter which «opens» the memorization can be only the rst transmitter memorized.
If the option PLUS is OFF the remote memorization is disabled.
If the option PLUS is ON the remote memorization of a new transmitter can be done using any transmitter already in memory.
The memorization PLUS is active only if there is, at least, one transmitter in the memory. When the memory is empty, the memorization of the rst
transmitter can be e󰀨ected only using the buttons P1 and P2.
!(*) Attention : this operation will overwrite all data of the internal memory
Manufactured by : CDVI Wireless SPA - Via Piave, 23 - 31020 S.Pietro di Feletto (TV) - Italy
Tel : +39-0438-450860 - Fax : +39-0438-455628
web: www.erone.com - email: [email protected]
External
Internal
External
Internal
Save
Restore (*)
MEM.
MEM.
MEM.
MEM.
Allows to create a backup of the memory data-base and save it onto an external
memory ( type SEL2641-MXPL) ( g. 6)
Plug-in the memory in the proper receiver connector
The memorization PLUS allows to add a new transmitter remotely, without using the push-buttons P1 & P2. It’s enough to use a transmitter «Ma-
ster».
A transmitter «Master» can be :
1) the rst transmitter added;
2) any transmitter memorized and changed as «master» using the Add Master submenu ;
The PLUS feature can be : ON, Limited or OFF
• Plus ON : remote transmitter memorization enabled;
• Plus Limited : remote transmitter memorization enabled only using a TX «master» ( see g. 7 );
• Plus OFF : remote transmitter memorization disabled;
Fig. 6
11 Menu Delete
12 Menu Info
Delete TX : Delete a transmitter. It’s necessary to have the transmitter available because the
system requires the RF transmission;
Delete Button : Delete the single button of a transmitter;
Delete by List : Delete a transmitter from a list. In this case it is enough to know the S/N of the transmitter
to be deleted to nalize the cancellation;
Delete All TX : Delete all transmitters;
Delete setting : Reset to factory default: delete all the transmitters and reset the relay operating mode
to PULSE.
For all the options, use P2 to scroll and P1 to conrm
Info relay : Display relay operating mode
Info N. Users : Display number of Tx memorized
Info List : List of Transmitters
Info Version : SW release.
For all the options, use P2 to scroll and P1 to conrm
Fig.7
ERONE
XPL2P
IS-XPL2PERUK Rev. 1 del 13.06.2017

Other CDVI Receiver manuals

CDVI ERONE SEL2641R433-XPL4V User manual

CDVI

CDVI ERONE SEL2641R433-XPL4V User manual

CDVI RADIUM WRW User manual

CDVI

CDVI RADIUM WRW User manual

CDVI DIGITAG-LR User manual

CDVI

CDVI DIGITAG-LR User manual

CDVI SEL2641R433-XPL5 User manual

CDVI

CDVI SEL2641R433-XPL5 User manual

CDVI Digitag LR DTRR1434R User manual

CDVI

CDVI Digitag LR DTRR1434R User manual

CDVI SEL2641R433-XPL2V User manual

CDVI

CDVI SEL2641R433-XPL2V User manual

CDVI ERONE SEL2641R433-XPL1V User manual

CDVI

CDVI ERONE SEL2641R433-XPL1V User manual

CDVI SEL2641R433-XPL User manual

CDVI

CDVI SEL2641R433-XPL User manual

CDVI SELWR433-SAT User manual

CDVI

CDVI SELWR433-SAT User manual

CDVI RX26-XPL5-GFA User manual

CDVI

CDVI RX26-XPL5-GFA User manual

CDVI DIGITAG-LR DTRR1434R User manual

CDVI

CDVI DIGITAG-LR DTRR1434R User manual

CDVI SEL2641R433-XPL4P User manual

CDVI

CDVI SEL2641R433-XPL4P User manual

CDVI ERONE SELWR433 User manual

CDVI

CDVI ERONE SELWR433 User manual

CDVI SEL2641R433-XPL User manual

CDVI

CDVI SEL2641R433-XPL User manual

CDVI SEL128R433-WPL User guide

CDVI

CDVI SEL128R433-WPL User guide

CDVI SEL2641R433-IP User manual

CDVI

CDVI SEL2641R433-IP User manual

Popular Receiver manuals by other brands

STONEX S800A user manual

STONEX

STONEX S800A user manual

JVC RX-6500VBK - Dolby Digital/DTS Audio/Video... instructions

JVC

JVC RX-6500VBK - Dolby Digital/DTS Audio/Video... instructions

Arylic Up2Stream Pro user manual

Arylic

Arylic Up2Stream Pro user manual

NOVAK NER 2S manual

NOVAK

NOVAK NER 2S manual

Delta Electronics RA1010-SAODT-IL Specifications

Delta Electronics

Delta Electronics RA1010-SAODT-IL Specifications

Ericsson LBI-38505A Maintenance manual

Ericsson

Ericsson LBI-38505A Maintenance manual

Pioneer MVH-S512BS Operation manual

Pioneer

Pioneer MVH-S512BS Operation manual

Boss marine MR3.6V user manual

Boss marine

Boss marine MR3.6V user manual

Harman Kardon AVR 335 quick start guide

Harman Kardon

Harman Kardon AVR 335 quick start guide

Motorola TIME WARNER DCT6200 user guide

Motorola

Motorola TIME WARNER DCT6200 user guide

Yamaha RX-V1500 owner's manual

Yamaha

Yamaha RX-V1500 owner's manual

Kenwood KMM-BT205 instruction manual

Kenwood

Kenwood KMM-BT205 instruction manual

Topfield TRF-7170 user guide

Topfield

Topfield TRF-7170 user guide

Pioneer AVH-269BT owner's manual

Pioneer

Pioneer AVH-269BT owner's manual

Panasonic RF-B65D Service manual

Panasonic

Panasonic RF-B65D Service manual

Philips DSR 9004 quick start guide

Philips

Philips DSR 9004 quick start guide

Pioneer MVH-2300NEX installation manual

Pioneer

Pioneer MVH-2300NEX installation manual

Velleman VAS5R user manual

Velleman

Velleman VAS5R user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.