5.0 INSTALLATION NOTES AND ASSEMBLY INSTRUCTIONS
5.1 These SSP-350-X-130 units are intended to be used with the CEECO
optional QLink ring down unit. However, they may be connected to a
Central Office or PBX ring down line. The CEECO QLink ring down unit
requires 110-120 VAC. *Grounding and installation must be in
accordance with all applicable local and national electrical and
building codes.
5.2 Determine the desired and safe mounting location for the QLink device.
Do not plug it into the AC power until the total installation of the
visitation units is completed.
5.3 The SSP-350-X-130 is designed to be on a vertical surface. A longer line
cord may be substituted if necessary. Route the cord as required and
utilize the appropriate conduit hole on the mounting box. Plug the
remaining holes with the supplied conduit plugs. Install the mounting
boxes as desired.
NOTE: Modular line cords may be substituted with simply wire pairs of
22-26 gauge stranded wire. Spade lugs may be required.
5.4 Run the modular cords or wires through the selected conduit hole in the
mounting box. Mount the panel telephone unit, utilizing the security
screws provided, to the mounting box. The security tool, which is sold
separately, must be used for the security screws.
5.5 Attach the modular cords or wires, as appropriate, to the QLink or other
ring down line. The phone units plugged into the same Qlink or attached
to the same ring down line will allow talk paths to one another. Plug the
QLink into the AC power or activate ring down line and the units will be
ready for use.
5.6 For mobile use a standard DC to AC power inverter may be required if
24VDC is not available.
***** WARNING *****
A. Never install telephone wiring during a lightning storm.
B. Never install telephone jacks in wet locations unless the jack is
specifically designed for wet locations.
C. Never touch uninsulated telephone wires or terminals unless the
telephone line has been disconnected at the network interface.
D. Use caution when installing or modifying telephone lines.