Ceia HI-PE/CF Series Installation manual

02PN8 HI-PE/CF --- Rev. F044GB60K10 1
METAL DETECTOR
HI-PE
Additional information for the
HI-PE/CF Series
ATTENTION!
Keep the transducer matched with the electronics unit and the Technical Booklet which have the same
serial number.
Program Version: N86V634x Rev.: F/044GB60K10 Date 15 / 11 / 1999

02PN8 HI-PE/CF --- Rev. F044GB60K10
2
Contents
CONTENTS..........................................................................................................................................................2
I - DESCRIPTION.................................................................................................................................................3
DOCUMENT CONTENTS ........................................................................................................................................3
SPECIAL FEATURES OF THE HI-PE/CF SERIES......................................................................................................3
CONSTRUCTION OF THE METAL DETECTOR...........................................................................................................4
Electronics Unit...........................................................................................................................................4
Antenna.......................................................................................................................................................4
II - INSTALLATION ..............................................................................................................................................5
ASSEMBLY ..........................................................................................................................................................5
Mechanical assembly.....................................................................................................................................5
Fixing the antenna in a cabin: column orientation.......................................................................................5
III – ISTRUCTIONS FOR USE .............................................................................................................................6
SWITCHING ON THE METAL DETECTOR.................................................................................................................6
IV - PROGRAMMING...........................................................................................................................................7
Characteristics................................................................................................................................................7
New programming parameters, or those only present on some standard models........................................7
ANALYSIS PROGRAMS AVAILABLE WITH THE COMMAND "IS" ..........................................................8
V - TECHNICAL CHARACTERISTICS................................................................................................................9
VI - MAINTENANCE.............................................................................................................................................10
SPARE PARTS......................................................................................................................................................10
HI-PE/CF-AS-140...........................................................................................................................................10
Accessories....................................................................................................................................................10
DECLARATION OF CE CONFORMITY............................................................................................................11
CEIA reserves the right to make changes, at any moment and without prior notice, to the models (including programming), their accessories and optionals, to the prices and
conditions of sale.

02PN8 HI-PE/CF --- Rev. F044GB60K10 3
I - DESCRIPTION
Document contents
Externally, CEIA HI-PE/CF Series metal detectors appear identical to
standard HI-PE models, and only differ in having some modifications to the
antenna and to the programming parameters.
This document illustrates these specific modifications, and we would refer
users to the manual included with all models for more general information.
Special features of the HI-PE/CF Series
The transit of metal personal effects in common daily use through Metal Detector checkpoints generates
signals which often exceed those of some types of fire-arm available on the market. Discrimination of the
these by the Metal Detector therefore becomes a necessary condition for establishing access systems with
high flow rates.
As a solution to this problem, CEIA presents its new HI-PE/CF Metal Detector which, with its detection
functions based on an innovative signal analysis system, raises the threshold of discrimination between
medium-sized fire-arms and personal effects to a level up to 400% above that of the 02PN8 HI-PE
model.
The advantages of using this new Metal Detector are the following: a notable reduction in the need for branch
staff to act to check inward- and outward-bound traffic; increase in convenience of access to the bank for
customers; and, not least, the opportunity to increase the level of security.
Statistical data obtained in real operating situations with the HI-PE/CF Metal Detector have demonstrated the
almost total elimination of false alarms compared with earlier systems, at the same level of detection capability
relating to fire-arms of conventional construction and in light metal, such as the Beretta 6.35mm.
The HI-PE/CF Metal Detector keeps the same dimensions and programming characteristics as the 02PN8 HI-
PE Metal Detector, so that it can be fitted into systems which were designed for the earlier model. As far as its
application is concerned, the parameters already in use for walk-through Metal Detectors remain valid, in
particular the importance of the electromagnetic compatibility of the metal structure.
In order to guarantee the levels of performance described above, use of this new Metal Detector is restricted to
cabins previously certified for electromagnetic compatibility with the HI-PE/CF Metal Detector.

02PN8 HI-PE/CF --- Rev. F044GB60K10
4
Construction of the Metal Detector
Electronics Unit
The HI-PE/CF electronics unit differs externally from the standard version only in the model logo.
Fig. I-1: HI-PE/CF electronics unit
Antenna
The following table illustrates the special features of the HI-PE/CF antenna models:
Model Modifications
HI-PE/CFPNAS600 Corresponds to model HI-PE/PN-AS-600. Useful passage width: 680-
820mm
HI-PE/CF No external modification compared with version HI-PE/CN-AS-140.
Useful passage width limited to 740mm (widened passage width version
HI-PE/CN-AS-140L not available).
HI-PE/CF-EN Corresponds to model HI-PE Elliptic. No external modification
HI-PE/CF-EW (waterproof) Corresponds to model HI-PE Elliptic waterproof. No external
modification
Fig. I-2a: 02PN8 HI-PE/CF-AS Fig. I-2ba: 02PN8 HI-PE/CF-EN Fig. I-2c: 02PN8 HI-PE/CF-PN-AS-600

02PN8 HI-PE/CF --- Rev. F044GB60K10 5
II - INSTALLATION
Assembly
Mechanical assembly
Fixing the antenna in a cabin: column orientation
Installation of the antenna in a metal cabin generally requires a test by qualified CEIA technicians.
As a result of the test, the installer is provided with any technical notes needed for installation, including
instructions on how to orientate the antenna when attaching it to the base structure.
Orientation of the columns is achieved by referring to the two coloured markings Cto be found near the
electronics unit connecting cable.
CC
Fig II-1a –Example of column antenna arrangement, with markings Cfacing each other
CC
Fig II-1b - Example of column antenna arrangement, with markings Cnot aligned

02PN8 HI-PE/CF --- Rev. F044GB60K10
6
III –ISTRUCTIONS FOR USE
Switching on the Metal Detector
After turning ON the equipment, an audible signal will sound and the display of the electronics unit will show
the following information:
CEIA
HIPE CF
WAIT
- - - -
Fig. III 1
MANUFACTURER
MODEL
ALARM INDICATION TEST
INITIAL ADJUSTMENT PHASE
NORMAL OPERATION

02PN8 HI-PE/CF --- Rev. F044GB60K10 7
IV - PROGRAMMING
Characteristics
Programming parameters not applicable SS, G1, G2, TP, CS, AU, FQ
New programming parameters, or those only present
on some standard models CM, RO, TI
Modified programming parameters IS
New functions, or those only present on some
standard models Direct display of the level of
security IS
New programming parameters, or those only present on some standard
models
Code Meaning Possible
values Type Notes
CM Cabin model 0-4 C/R Siting of an HI-PE/CF antenna inside a metal structure generally requires a test
to be carried out by CEIA technicians. For installation to be possible in cabins
with different characteristics, these tests must be carried out on a sample unit of
each type.
CEIA stores the optimum configuration of the device for each cabin which has
been tested.
The CM command allows the installer to select the configuration according to the
cabin used.
The correspondence between the numerical values of the CM setting and the
type of cabin is specified in the CEIA test report, which also specifies the string of
characters which appears on the display during selection as a concise
denomination of the type of cabin. The 0 setting is usually reserved for the open-
space configuration without surrounding metal structure.
E.g. :
Message Numerical Comment
value
FREE680 0Metal detector without surrounding metal structure,
useful passage width 680mm (model HI-
PE/CF-AS-140
CABINA 1 1Metal detector installed in a cabin of the 1st type
CABINA 2 2Metal detector installed in a cabin of the 2nd type
CABINA 3 3Metal detector installed in a cabin of the 3rd type
VOID 4Free memory, usable for a new configuration in the
future
RO Read out of the
reception signal 0-9995 R This displays the result of the processing of the reception signals, by means of a
numerical indication. It can display values from 0 to 9,995.

02PN8 HI-PE/CF --- Rev. F044GB60K10
8
Code Meaning Possible
values Type Notes
Display indication: When the value is under the alarm threshold, the indication is green,
when the value is above the alarm threshold, the indication is red.
IS International
Security
Standard
see the
followin
g table
C,R
TI Transmitter
inhibitor NO,
YES Deactivates the transmitter if the Metal Detector is inhibited.
The Metal Detector behaves as follows in the two different situations:
TI=NO the metal detector is immediately operational when the inhibition signal
is switched off
TI=YES when the inhibition signal is switched off, the Metal Detector resets; in
this case, it is necessary to wait a few moments (0.5 – 2 sec) before the
Metal Detector is operational (tr in the diagram below)
inhibition
signal
TX
alarm
relay
tr
inhibition
TX inactive
reset normal
operation
0,5 - 2s Fig. IV-1
Delay before the metal detector is operational with TI=ON: after deactivation of
the inhibition signal, it is necessary to wait for time tr before the detector
reactivates
ANALYSIS PROGRAMS AVAILABLE WITH THE COMMAND "IS"
PROGRAM IS DISPLAY
MESSAGE* SECURITY LEVEL / APPLICATION SAMPLES
1NIL.1 Standard : NILECJ-STD-0601.00 Security Level 1 AM9
2NIL.2BA Standard : NILECJ-STD-0601.00 Security Level 2
Basic specifications AM7
3NIL.3BA Standard : NILECJ-STD-0601.00 Security Level 3
Basic specifications AM5
4NIL.2AD Standard : NILECJ-STD-0601.00 Security Level 2
Additional specifications AM7; AN7
5NIL.3AD Standard : NILECJ-STD-0601.00 Security Level 3
Additional specifications AM5; AN5
6HIGH IMM Level with high immunity to environmental
interference (corresponding approximately to level
NILECJ 2, with additional specifications).
-
* The display message also appears when not in programming if the key is pressed.
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;;
;;
;
;
;
;
;
;
;
The unit is programmed in the factory to ensure operation according to the IS standards for the passage width
listed in the "Hardware and software configuration sheet" included at the end of the manual. If, for any reason,
the passage width has been changed, this correspondence is not guaranteed.

02PN8 HI-PE/CF --- Rev. F044GB60K10 9
V - Technical characteristics
Main characteristics
•Adjustable sensitivity with wide range of settings.
•International standards: Direct selection of International Security Standards.
•Extremely high discrimination.
•Extremely high immunity to both mechanical and electromagnetic interference.
•Programmable operation controlled by microprocessor.
•Programming: via incorporated keypad and display or via RS232/RS485 serial link from a personal
computer or computer network.
•Access to programming protected by mechanical lock and two alphanumeric passwords.
•Automatic, cable-free synchronisation between two or more metal detectors, at a minimum distance of
5cm from each other.
•Highly integrated, highly reliable professional electronics.
•Electronics control unit separate from the detector.
•No initial or periodic calibration.
•Easy maintenance. The electronics unit can be replaced in less than one minute.
•Colour: light grey, RAL 7040
Alarms
•Audible signal: Buzzer - 90 dBA (1 m).
•Relay output: Switch contact NA, NC, C - 1 A - 24 Vdc.
•Reset: PP input, automatic or manual, N.C. contact.
•Inhibition: INI input, N.A. contact.
•Self-diagnosis: Incorporated, with intermittent audible signal.
Certification and compliance
•Harmless to wearers of pacemakers, life-support systems, pregnant women and magnetic media (floppy
disks, audio-cassettes, video-cassettes and similar).
•Complies with NILECJ-0601-00 standards for all security levels.
•Complies with EC regulations and international standards on electrical safety and electromagnetic
compatibility (EMC).
Installation data
•power supply: 20 ÷30 Vdc, 25VA max.
•Inputs: RS-232C interface for connection to a terminal, computer or external modem; RS-232C interface
for connection to other CEIA Metal Detectors.
•Temperature and relative humidity: from -15°C to +70 °C; from 0 to 95% (without condensation)
•Dimensions and weight of the electronics unit: 380 x 157 x 82 mm / 1.2 kg.
Accessories / Options
Metal test samples.

02PN8 HI-PE/CF --- Rev. F044GB60K10
10
VI - MAINTENANCE
Spare parts
HI-PE/CF-AS-140
Validity: revision 1.0, 17/07/1999
Replacement parts
Description Quantity Code
Electronics unit IP20 118292
Electronics unit card 06012SCD60 118754
Connector cap 112521
Column RX N076 118290
Column TX N076 118291
Complete electronics unit container 119045
Cover complete with lock 14074
Electronics unit key kit 18471
In all component orders please indicate the serial number of the device
Accessories
Validity: revision 1.0, 9/11/1999
Replacement parts
Description Quantity Code
European mains power supply unit 119208
USA mains power supply unit 119825
MDScope 117469
Nilecj Std 0601.00 level 1 samples 13501
Nilecj Std 0601.00 level 2 samples 13497
Nilecj Std 0601.00 level 3 samples 13498
In all component orders please indicate the serial number of the device

02PN8 HI-PE/CF --- Rev. F044GB60K10 11
DECLARATION OF CE CONFORMITY
DECLARATION OF CONFORMITY CE
DECLARATION DE CONFORMITE CE KONFORMITÄTSERKLÄRUNG CE
DECLARACION DE CONFORMIDAD CE DICHIARAZIONE DI CONFORMITÁ CE
Manufacturer
Fabricant / Herstellers / Fabricante / Costruttore: CEIA S.p.A.
Strada Provinciale di Pescaiola 54/G 52040
Viciomaggio - Arezzo - ITALY
Declares that the product
déclare que ce produit / erklärt, daß das Produkt / declara que el producto / dichiara che il prodotto:
Product name:
Nom du produit: / Produktname:
Nombre del producto: / Nome:
Metal Detector
Détecteur de Métaux / Elektronischer Metalldetektor
Detectores de metales / Metal Detector Elettronico
Model
Série / Serie / Serie / Modello: HI-PE/CF
conforms to the following Product Specifications
est conforme aux spécifications suivantes / folgenden Produktspezifikationen entspricht / es conforme a las siguientes especificaciones / è
conforme alle seguenti specifiche di prodotto:
Safety/ Sécurité / Sicherheit / Seguridad / Sicurezza:
EN 61010-1 - 1 (1993)
This product complies with the requirements of the Low Voltage
Directive 73/23/EEC and following modifications indicated in the
93/68/EEC Directive.
Le produit ci-dessus répond aux exigences de la Directive
73/23/CEE et aux modifications suivantes mentionnées dans la
Directive 93/68/CEE concernant la basse tensions.
Dieses Produkt entspricht den Anforderungen an
Niederspannungsgeräte gemäß der Norm 73/23/EEC und
nachfolgender, in der Norm 93/68/EEC angegebener Änderungen.
El producto indicado cumple los requisitos de la Low Voltage
Directive 73/23/CEE y siguientes modificaciones indicadas en la
Directiva 93/68/EEC.
Il prodotto è conforme alle norme della direttiva 73/23/EEC e
successive modifiche indicate nella direttiva 93/68/EEC sulla bassa
tensione.
EMC CISPR 11: 1990 / EN 55011: Group 1 - Class B
EN 61000-4-2: 1995
EN 61000-4-3: 1995
EN 61000-4-6: 1995
ENV50204:1994
EN 61000-4-4: 1995
This product complies with the requirements of the EMC Directive
89/336/EEC and following modifications indicated in the
93/68/EEC Directive.
Le produit ci-dessus répond aux exigences de la Directive
89/336/CEE et aux modifications suivantes mentionnées dans la
Directive 93/68/CEE concernant les interférences
électromagnétiques.
Dieses Produkt entspricht den Anforderungen der EMC-Norm
89/336/EEC und nachfolgender, in der Norm 93/68/EEC
angegebener Änderungen.
El producto indicado cumple los requisitos de la Directiva EMC
89/336/CEE y siguientes modificaciones indicadas en la Directiva
93/68/EEC.
Il prodotto è conforme alle norme della direttiva EMC 89/336/EEC e
successive modifiche indicate nella direttiva 93/68/EEC.
Arezzo, 1997 / 11 / 15 SpA
Person in charge Lab. EMC
Resp. Laboratoire EMC / Laborattaché EMC
Resp. Laboratorio EMC / Resp. Lab. EMC
Ing. E. Sorini
This manual suits for next models
4
Table of contents
Other Ceia Metal Detector manuals
Popular Metal Detector manuals by other brands

Fisher Research Labs
Fisher Research Labs F75 Special Edition Comprehensive operating manual & guide

2M Technology
2M Technology 2MTHWT-HMD quick guide

Tesoro
Tesoro Outlaw Operator's instruction manual

Velleman
Velleman CS300 user manual

MCD
MCD MCD-3003B2 operating manual

Barska
Barska Winbest Elite-200 Edition user manual

Fisher Research Labs
Fisher Research Labs F2 operating manual

Whites
Whites Beachcomber TR operating instructions

Whites
Whites Coinmaster Classic instruction manual

C-SCOPE
C-SCOPE CS6MX operating instructions

Whites
Whites Goldmaster 63TR operating instructions

JW Fishers
JW Fishers PULSE 8X Operation manual