Cellink INKREDIBLE User manual

1
INKREdIBLE
User manual
CELLINK AB
Arvid Wallgrens Backe 20
Gothenburg, SE 41346
SWEDEN

Hello and welcome to the excing world of
3D Bioprinng!
We are excited to have you here. The technology
you have in front of you has the potenal of creang
real, live human ssues and it is only your imaginaon
that limits what you can do. This manual will serve
as your guide for seng up your INKREDIBLE 3D
Bioprinter, maintaining it, and also nofying you
about safety precauons to ensure a long-lasng
product lifeme. Make sure you read the enre
manual before using the product for the rst me.
Let`s begin this excing journey!

1. Safety informaon 4
1.1 General safety informaon 6
1.2 Protecve equipment 7
1.3 Liquids and dispensing media 7
1.4 Opening the product and service 7
2. Introducon to your INKREDIBLE 3D Bioprinter 8
2.1 Specicaons 10
3. Unpacking your INKREDIBLE 3D Bioprinter 12
3.1 Contents of the box 15
4. Product map 18
5. Operang your INKREDIBLE 3D Bioprinter 20
5.1 Seng up for rst me use 22
5.2 Starng a print 23
5.3 Advanced features 26
6. How to install and setup HeartWare 28
6.1 Installing Heartware (PC) 30
6.2 Installing Repeer-Host (Mac) 34
6.3 Seng up HeartWare 39
7. Slicing with HeartWare 42
7.1 What is Slicing? 44
7.2 HeartWare interface 45
7.3 Basic slicing workow 49
8. Maintenance and support 54
8.1 Maintaining your INKREDIBLE 3D Bioprinter 56
8.2 Support for your INKREDIBLE 3D Bioprinter 58
9. Warranty and guarantee 62
Contents

4
1. Safety informaon

5

6
WARNING! This symbol will indicate if there is risk of personal injury.
CAUTION! This symbol will indicate if there is risk of causing damage to your
INKREDIBLE 3D Bioprinter or other equipment.
Before you start using your INKREDIBLE 3D bioprinter, please take me to review the
enre manual. Maloperaon of the INKREDIBLE 3D bioprinter instrument can lead to
severe and irreversible injuries if the safety instrucons are not followed. Throughout the
manual we will use the following two symbols to indicate if there is risk for equipment
damage or personal injury:
In order to respond to the INKREDIBLE 3D Bioprinter and its relevant security
requirements, the instrument has to be operated by trained personnel, who are aware
of the risks and dangers that can be induced to themselves, as well as for the sta
being in close proximity with the INKREDIBLE 3D Bioprinter. The sta being involved
in the installaon, or the maintenance of the system or a part of the system, has to be
qualied through appropriate training. Use the instrument only for its intended purpose
as described in the documentaon. Do not modify the instrument, sub-components or
accessories.
1.1 General safety informaon
WARNING! Never reach into the instrument unl all components of the instrument
have come to a complete stop. Moving parts can cause serious injuries.
WARNING! Before cleaning, inspecng, adjusng, repairing or disassembling the
instrument or the dispensing units, stop the instrument, turn o the main switch
and disconnect if from its electrical power source.
WARNING! The INKREDIBLE 3D Bioprinter is ed with a 365nm (405nm
oponal) UV LED. Do not look directly at the light source. Always wear protecve
gear when operang the system, including UV protecve goggles.
WARNING! Improper mounted pressurized air spouts, liquid spouts or cartridges
can be dangerous. Verify that all connecons are properly connected and all
components are specied for use with the intended pressure. Verify that the
supplied air pressure does not exceed 400 kPa.
In addion to the manual, we are connously uploading instrucon videos on our
YouTube-channel, CELLINK3D. To access it go to:
hp://ny.cc/rbz7xy

7
1.2 Protecve equipment
WARNING! Always wear protecve goggles and gloves while handling dangerous
materials that can be absorbed by skin or which are toxic, strike-aracve,
corrosive, causing allergies, carcinogenic, reproducon-endangering or mutagenic
to humans.
WARNING! Always read the material safety data sheets, packing labels,
manufacturer or dealer’s catalogue rst and use adequate safety equipment.
1.3 Liquids and dispensing media
WARNING! Before starng to work with hazardous dispensing materials,
the operator has to be informed about the characteriscs of the material and
its compability with the dispensing unit. The informaon can be found in the
material safety data sheets, packaging labels, manufacturer or dealer catalogues.
Always use adequate safety equipment.
1.4 Opening the product and service
WARNING! The INKREDIBLE 3D Bioprinter SHOULD NOT be taken apart. Doing
so endangers both the users and the equipment! The INKREDIBLE 3D Bioprinter
IS NOT user servicable! Opening of the instrument’s electrical panel will void the
warranty.
WARNING! Always wear protecve goggles and gloves, and secure the environment
around instrument from other personnel while operang the INKREDIBLE 3D
bioprinter. All safety equipment, including UV protecve safety goggles, must be
used when operang the UV curing system.

8
2. Introducon to your INKREDIBLE
3D Bioprinter

9

10
The INKREDIBLE 3D bioprinter is a pneumac-based extrusion bioprinter with dual
printheads and UV LED curing system for bioprinng of complex human ssue models
and organs for ssue engineering research. It is a cost-eecve unit for innovators
to enter the 3D bioprinng eld and start bioprinng living ssues at ease. It can be
used as a standalone unit thanks to its LCD controller or it can be monitored through
a computer with the use of the accompanied soware. Your three-dimensional CAD
models are translated into coordinates and instrucons for the INKREDIBLE to allow the
bioprinter to move according to a dened path. The bioprinng process works through
the extrusion of a bioink or hydrogel biomaterial combined with human cells in a boom-
up, layer-by-layer fashion unl a 3D construct is built. Once the construct has been
bioprinted, it is crosslinked using the UV LED curing system or ionic soluons, depending
on your bioink’s crosslinking requirements.
2.1 Specicaons
2.1.1 Bioprinng
Bioprinng Technology: Pneumac-based microextrusion system
Printheads: 2 pneumac-based extrusion printheads.
1 UV LED curing system 365 nm (405 nm oponal)
Build Volume: 130 x 80 x 50 mm. Printbed has Insets for P100 petri dish and mul-
well plates
Posioning Precision: XY: 10 µm [0.0004 in]; Z: 2.5 µm [0.0001 in]
Layer Resoluon: 100 µm [0.0039 in]
Hydrogel’s viscosity range: 0.001 to 250 Pa.S [1 to 250,000 cP]
Max. Operang Pressure: 700 kPa
Set Pressure Range: 5 to 400 kPa
Sensivity: Within 0.2% F.S. (0.8 kPa)
Repeatability: Within ±1% F.S. (4 kPa)
Minimum Unit Seng: 1 kPa
Pressure Display Units: kPa, MPa, kgf/cm2, bar, psi, inHg and mmHg
Printhead’s Response Time: 5 ms or less (ON), 4 ms or less (OFF)
Nozzle Length: Auto-calibraon, 6.35 mm [0.25 in] to 38.1 mm [1.5 in]
Nozzle Diameter: User dependent, 50 to 1540 µm

11
2.1.2 Soware
Soware Bundle: Slic3r, Repeer-Host, HeartWare
File Types: STL/OBJ/AMF
Supports: Windows (XP 32 bit/7+), Mac OS X (10.6 64 bit/10.7+) and Ubuntu Linux
(12.04+)
Connecvity: USB, SD-card
2.1.3 Physical specicaons
Frame: Chemically resistant, powder-coated high grade steel
D x W x H: 330 x 370 x 380 mm [19.1 x 16.5 x 14.7 in]
Shipping Box: 59 x 55 x 43 cm [23 x 21.5 x 17 in]
Shipping Weight: 20 kg [44.5 lbs]
2.1.4 Electrial
Power Supply Adapter:
Input: 100-240VAC, 50/60Hz, 2.0A
Output: 24VDC, 6.67A, 160W Max
Portable, Oil-free Air Compressor:
EU/UK/AU/CH: 230VAC, 50Hz
US/MEX/CA/JAP/Taiwan: 110VAC, 60Hz
INKREDIBLE 3D Bioprinter:
Input: 24 VDC, 6 A
2.1.5 IP-classicaon
IP10
CAUTION! If you want to use another air supply than the one provided by
CELLINK, please contact us to avoid damage to your INKREDIBLE 3D Bioprinter.

12
3. Unpacking your INKREDIBLE 3D
Bioprinter

13

14
Grab
here!
Grab
here!
www.CELLINK.com
When unpacking your INKREDIBLE 3D Bioprinter, be careful not to grab onto any
movable parts or lose components. We recommend you grab it by the side window
frames and pull it out from the box.
Once the INKREDIBLE 3D Bioprinter has been carefully taken out of the box, all protecve
lms, zip es and plasc parts prevenng the axes to move during transportaon can
be removed. Once all protecve materials have been removed, the INKREDIBLE can
be placed at its intended place of operaon (for example inside a biological hood or
laboratory bench).
WARNING! Always be two people present when unpacking your INKREDIBLE
3D bioprinter to avoid personal injury.
CAUTION! The INKREDIBLE should never be placed on wet, damp, moist or
humid surfaces.
CAUTION! Do not force or tear anything during the unpacking or setup process
as this may irreversibly damage your INKREDIBLE 3D Bioprinter.

15
3.1 Contents of the box
[1x] INKREDIBLE 3D Bioprinter
[1x] User manual
[1x] Electrical supply box containing:
[1x] 24 V Power supply
[1x] Power cord
[1x] USB cable
[1x] Consumables box containing:
[2x] 3mL cartridge with CELLINK START
[4x] 3mL cartridge with piston and end caps
[2x] Blue conical nozzles (GA 22)
[2x] Red conical nozzles (GA 25)
[2x] White conical nozzles (GA 27)
[1x] Straight stainless steel nozzle (GA 22)
[1x] 24 well plate
[1x] Glass petri dish
[1x] UV-protecve goggles
[1x] Tube with adapter to air compressor
[1x] Air supply box containing:
[1x] 150 W, 300 kPa portable, oil-free air compressor
[1x] STARTINK-kit containing:
[1x] Cell syringe
[1x] Prelled syringe with 3 mL of CELLINK Bioink
[1x] Dispensing unit
[1x] Mixing unit
[1x] Filling cartridge
[2x] 5 ml of crosslinking soluon
[1x] Material safety data sheet
[1x] Applicaon note

16
4. Product map

17

18
INKREdibLE
2a
2b
5a 5b 6
9
81
7a 7c
7b
3
4
10a
10b
13 1412
11 a 7c
7b 11 b

19
[1] On/O Buon
[2a] Printhead 1 (Ph 1)
[2b] Printhead 2 (Ph 2)
[3] UV LED
[4] Printbed
[5a] Digital pressure monitor for printhead 1
[5b] Digital pressure monitor for printhead 2
[6] SD-card reader
[7a] Printbed adjustment buery screw
[7b] Printbed adjustment buery screw
[7c] Printbed adjustment buery screw
[8] Control knob
[9] Main LCD display
[10a] Cartridge air connector for printhead 1
[10b] Cartridge air connector for printhead 2
[11a] Pressure regulator for printhead 1
[11b] Pressure regulator for printhead 2
[12] Power input
[13] Pressure connector
[14] USB input

20
5. Operang your INKREDIBLE 3D
Bioprinter
Table of contents
Other Cellink 3D Printer manuals