manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Chamberlain
  6. •
  7. Keypad
  8. •
  9. Chamberlain LiftMaster TAC2C User manual

Chamberlain LiftMaster TAC2C User manual

COLOR LABEL DESCRIPTION
POWER 16 Volt DC power input
AUTOCALL Input for accessory device to
trigger home dialing
PHONE/TELCO Input connection for TELCO
RELAY 2, NO NO input for Relay 2
RELAY 2, NC NC input for Relay 2
RELAY 2, COM COM input for Relay 2
RELAY 1, NO NO input for Relay 1
RELAY 1, NC NC input for Relay 1
RELAY 1, COM COM input for Relay 1
2
1Unplug the transformer from the outlet. Disconnect the
wires from the existing transformer.
Remove the screws from the Crown Jewel faceplate
using the provided hex tool.
Slide the faceplate forward and rotate downward.
Identify the terminal blocks on the Crown Jewel board. Attach the provided labels to the
corresponding wires as shown. Once the wires are labeled, remove them from the board.
SPECIFICATIONS
Power Supply: 16 Vdc 2.5 Amp
The 110 Vac outlet must be dedicated to the unit only. This outlet
should be wired back to its own 10 Amp minimum circuit breaker.
This will prevent two problems:
• Other equipment cannot introduce spikes, noise, surges, or dips
into the power circuit.
• The unit’s operation will not be affected if any other equipment
develops a short circuit across the power line.
Hardware Bag
Complete with: Hex Head Tamper Resistant Screws (4), Hex Tool (1),
and Ground Lug (1)
Faceplate with Processor Board (1)
16 Volt DC 2.5 Amp Transformer (UL Listed) (1)
Install and Programming Guide (1)
Labels (9)
CARTON INVENTORY
Introduction 4
POWER
EXTERNAL KEYPAD
(no longer available)
RELAY 1
RELAY 2
DO NOT run data wires and HIGH VOLTAGE wires in the same
conduit. The HIGH VOLTAGE wires may interfere with the data
wires and cause the unit to malfunction.
To AVOID damaging gas, power or other underground utility lines,
contact underground utility locating companies BEFORE digging.
To prevent damage to the unit:
• Use the new 16 Vdc transformer ONLY.
• Use dedicated 110 Vac outlet ONLY.
Installation Guide
TAC2C
TAC1 RETROFIT KIT FOR CROWN JEWEL SYSTEMS
Autocall
Terminal
Block
Exit Terminal Block
(no longer available)
Separate the Exit terminal block
from the Autocall terminal block by
sliding them apart as shown.
AUTOCALL
EXIT
(no longer available)
PHONE/TELCO
When the wires have
been labeled correctly,
remove the terminal
blocks from the board.
RELAY 1, COM
RELAY 1, NC
RELAY 1, NO
RELAY 2, COM
RELAY 2, NC
RELAY 2, NO
The relay wires will need to be
removed and re-wired to the terminal
block on the new board.
5Remove the screws (2) securing the faceplate to the
housing.
Ground Wire
Remove the ground wire
that runs from the board
to the ground screw in
the existing housing.
123
456
789
*0#
6.22"
Keypad
Speaker
Call Button
9.72"
Dimensions: 9.72" x 6.22" (W x H)
CROWN JEWEL BOARD
IMPORTANT: The TAC2C has a Ringer Equivalence Number (REN) of 5 with or without a TELCO line.
3
Microphone
IMPORTANT NOTE: DO NOT use the existing transformer, the
provided transformer MUST be used instead.
© 2011, The Chamberlain Group
01-35895B All Rights Reserved
When wiring is complete, secure the new faceplate to
the existing housing with the provided screws (4). SET THE MASTER CODE
Once power is applied, the unit will begin to “click” to
indicate that it is powered, and is waiting to be programmed for
the unit’s Master Code. The Master Code is used to unlock the
programming functions of the unit. The Master Code should not
be distributed as a User Code.
Enter on the unit’s keypad.
Enter 4-digit Master Code. Example: 1234.
“BEEP” “BEEP”
Write down the Master Code and store in a secure
location.
1
2
3
123
456
789
*
0#
R
E
L
A
Y
1
C
O
M
R
E
L
A
Y
1
N
O
R
E
L
A
Y
1
N
C
R
E
L
A
Y
2
N
C
R
E
L
A
Y
2
N
O
R
E
L
A
Y
2
C
O
M
R
E
L
A
Y
1
C
O
M
R
E
L
A
Y
1
N
O
R
E
L
A
Y
1
N
C
R
E
L
A
Y
2
N
C
R
E
L
A
Y
2
N
O
R
E
L
A
Y
2
C
O
M
Connect the power wires to the new transformer and
plug the transformer into a 110 Vac outlet ONLY, any
other type of outlet will cause damage to the unit.
NEW 16 Vdc
Transformer
(provided)
110 Vac Outlet ONLY
8
POWER
Ground Wire
Crimp the ground lug onto the end of the
ground wire on the new board. Attach the
ground lug to the ground screw in the
existing housing.
Rewire the relay 1 and 2 wires
to the relay 1 and 2 terminal
blocks on the new board.
Ground Lug
Ground Screw
in existing
housing
Remove the PHONE, POWER, and AUTOCALL
terminal blocks from the new board. Leave the
Relay 1 and 2 terminal blocks.
NEW TAC2C BOARD
AUTOCALL
PHONE/TELCO
RELAY 1 RELAY 2
POWER
AUTOCALL
PHONE/TELCO
Attach the labeled wires to the new TAC2C board as shown.
RELAY 1 RELAY 2
COM
NO
NC
COM
NO
NC
For complete programming information refer to the
Programming Guide.
6
7 9
Testing
TEST GATE / DOOR RELAYS
Test Relay 1
Enter 4 digit Master Code.
Press 1 to test Relay 1.
Test Relay 2
Enter 4 digit Master Code.
Press 2 to test Relay 2.
TEST THE TELEPHONE CONNECTIONS
Place a telephone call from the resident’s telephone to verify
the unit is operating properly, then hang up the phone.
Press the “Call” button on the unit’s keypad. The telephone in
the residence should ring.
To test Relay 1 have someone answer the telephone and enter
“*9” (Star + 9) to activate Relay 1. The unit will disconnect
the call as soon as the relay is activated. To test Relay 2 have
someone answer the telephone and enter “*5” (Star + 5).
Relay 2 should activate. The unit will disconnect the call as
soon as the relay is activated.
1
1
2
1
2
2
3
IMPORTANT NOTE: DO NOT use the existing transformer,
the provided transformer MUST be used instead.

Other Chamberlain Keypad manuals

Chamberlain WKP5LM3 User manual

Chamberlain

Chamberlain WKP5LM3 User manual

Chamberlain LiftMaster Professional 387LM User manual

Chamberlain

Chamberlain LiftMaster Professional 387LM User manual

Chamberlain LiftMaster Security+ WKP5LM User manual

Chamberlain

Chamberlain LiftMaster Security+ WKP5LM User manual

Chamberlain 747REV User manual

Chamberlain

Chamberlain 747REV User manual

Chamberlain EL Series User manual

Chamberlain

Chamberlain EL Series User manual

Chamberlain Clicker KLIK2U User manual

Chamberlain

Chamberlain Clicker KLIK2U User manual

Chamberlain Clicker KLIK2U User manual

Chamberlain

Chamberlain Clicker KLIK2U User manual

Chamberlain KPR2000 User guide

Chamberlain

Chamberlain KPR2000 User guide

Chamberlain 747EML Series User manual

Chamberlain

Chamberlain 747EML Series User manual

Chamberlain 747EV User manual

Chamberlain

Chamberlain 747EV User manual

Chamberlain KPR2000 User manual

Chamberlain

Chamberlain KPR2000 User manual

Chamberlain 850EV User manual

Chamberlain

Chamberlain 850EV User manual

Chamberlain LiftMaster ELITE EL25 Owner's manual

Chamberlain

Chamberlain LiftMaster ELITE EL25 Owner's manual

Chamberlain LiftMaster Security+ WKP250LM User manual

Chamberlain

Chamberlain LiftMaster Security+ WKP250LM User manual

Chamberlain KPR2000 User manual

Chamberlain

Chamberlain KPR2000 User manual

Chamberlain LiftMaster TAC2C Operating instructions

Chamberlain

Chamberlain LiftMaster TAC2C Operating instructions

Chamberlain Clicker KLIK2U User manual

Chamberlain

Chamberlain Clicker KLIK2U User manual

Chamberlain Clicker KLIK2U User manual

Chamberlain

Chamberlain Clicker KLIK2U User manual

Chamberlain KPW250 User manual

Chamberlain

Chamberlain KPW250 User manual

Chamberlain LiftMaster Q User manual

Chamberlain

Chamberlain LiftMaster Q User manual

Chamberlain LiftMaster ELITE EL25 User manual

Chamberlain

Chamberlain LiftMaster ELITE EL25 User manual

Chamberlain LiftMaster Professional 387LM User manual

Chamberlain

Chamberlain LiftMaster Professional 387LM User manual

Chamberlain 920GA User manual

Chamberlain

Chamberlain 920GA User manual

Chamberlain 780EV User manual

Chamberlain

Chamberlain 780EV User manual

Popular Keypad manuals by other brands

Vimar By-alarm 01705 user manual

Vimar

Vimar By-alarm 01705 user manual

RIDGE RESKEY 14-RK10 quick start guide

RIDGE RESKEY

RIDGE RESKEY 14-RK10 quick start guide

Bticino HC4608 user manual

Bticino

Bticino HC4608 user manual

Risco lightsys 2 Quick user guide

Risco

Risco lightsys 2 Quick user guide

Resolution CryptiX Setup manual

Resolution

Resolution CryptiX Setup manual

Vantage Hearth Equinox 41 EQ41TB-TI installation manual

Vantage Hearth

Vantage Hearth Equinox 41 EQ41TB-TI installation manual

SEA 23105198 manual

SEA

SEA 23105198 manual

Targus Numeric Keypad with 2 USB ports user guide

Targus

Targus Numeric Keypad with 2 USB ports user guide

Savant WPB-LV02 Series Quick reference guide

Savant

Savant WPB-LV02 Series Quick reference guide

aperta EZTAG3PRO quick guide setup

aperta

aperta EZTAG3PRO quick guide setup

SOMFY CLAVIER TOUCHE FILAIRE installation guide

SOMFY

SOMFY CLAVIER TOUCHE FILAIRE installation guide

Alarm Controls Corporation KP-300 operating instructions

Alarm Controls Corporation

Alarm Controls Corporation KP-300 operating instructions

Steren COM-626 user manual

Steren

Steren COM-626 user manual

AMC K-LCDW800 installation manual

AMC

AMC K-LCDW800 installation manual

AMX MIO-CLASSIC-S Dimensional drawing

AMX

AMX MIO-CLASSIC-S Dimensional drawing

Bosch B930 quick start guide

Bosch

Bosch B930 quick start guide

NAPCO MAGNUM ALERT RP3000 KEYPAD operating guide

NAPCO

NAPCO MAGNUM ALERT RP3000 KEYPAD operating guide

Beijing lanchuan KPID-9808 Operation guide

Beijing lanchuan

Beijing lanchuan KPID-9808 Operation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.