CLASSIC CONVECTION STEAMERS
15 PSI BOILER BASE STYLE
MODELS: 36-CGM-300
Cle eland Standard Features
I
I
Cooking Capacity for up to six 12˝ x 20˝ x 2
1
⁄
2
˝ deep Cafeteria Pans.
IIPressureless cooking with forced convection steam,
permitting doors to be opened while cooking continues.
I
ISolid State Controls operate water level and safety func-
tions.
I
I
Each compartment is equipped with a 60 minute mechanical
timer, separate bypass switch for constant steaming and a
cold water condenser for superior cooking results.
I
I
Instant Steam Standby Mode: Holds generator at steaming
temperature. Allows unit to start cooking instantly.
IIDurable 14 Gauge Stainless Steel Construction:
For Compartment Door and Steam Cooking Cavity.
IISeparate Main Power Switch for “On/Off”
IIExclusive Steam Cooking Distribution System: The
exclusive Convection Jets produce a high velocity
convection steam without fans. Coved Corner design in
cooking compartment distributes heat evenly and is easy to
keep clean. Creased top & bottom enhance drainage. Cold
Water Condenser for each compartment maintains a dry
steam. Fully insulated cooking compartment for thermal
efficiency. Removable Stainless Steel Slide Racks for easy
cleaning.
IIExclusive “Cool to the Touch” Compartment Door
Design: Free floating inner door with reversible door gasket
provides an air tight seal. Stainless Steel Slam/Latch Door
Latch mechanism provides greater reliability.
IILeft Hand Door Hinging: Compartment Doors hinged left,
controls on the right.
IIModular Cabinet Base with Hinged Door.
IIHigh Efficiency Gas Steam Generator with NickelGuard,
Electronic Spark Ignition and Automatic Water Fill on start up.
IIAutomatic Generator Drain at shutdown: Contains a
“Water Jet” Spray Rinse Cleaning Cycle to keep drain clear.
IIAutomatic Water Level Control System with Low Water
Power Cut-off Circuit.
IISteam generator equipped with High Limit Pressure Safety
Switch, 15 psi Safety Valve, and Steam enerator Pressure
auge.
IINSF Certified 6˝ Stainless Steel Legs with adjustable
flanged feet for a one inch level adjustment.
IIas Pressure Regulator and Control Valve.
II
Standard Voltage for Controls: 115 volts, 60 Hz, single phase.
IIAll Controls are serviceable from the front.
Options & Accessories
ËRight Hand Door Hinging, Controls on the Left (DHR)
Shall be Two Compartments, CLEVELAND Convection Steamer, Model 36
CGM _____ , Gas fired Steam Generator, NickelGuard, _____ M BTU. Solid
State Controls operate timing, water level and safety functions. Steam
Generator with Automatic Water Fill on start up, Automatic Blowdown with
additional Manual Drain Valve and Electronic Spark Ignition. For each cook
ing compartment: 60 minute Mechanical Timer, Manual Operation Mode and
Cold Water Condenser. Type 304 Stainless Steel cooking compartment.
ËElectronic Timer with Compensating Load Feature (ETC)
ËON/OFF Steam Switch only for compartment controls (MC)
ËCafeteria pans in depths of 1˝, 21⁄2˝, 4˝ and 6˝
ËCompartment Door Steam Shut Off Switch (SCS)
ËPower Take Off Kit ( PTO), Kettle Interconnecting Kit (IMK)
ËStainless Steel Base Frame (FSS)
ËStainless Steel Insulated Flue Cover (SSF)
ËQuick Disconnect for gas line (QDC)
ËSecondary Low Water Cut-Off, factory installed (CAL )
(Required for AZ. AR. CA. CO. CT. DE. FL. A. HI. IL. IA. KS. MD. MA. MI.
MN. MT. NE. NV. NM. NC. OK. OR. PR. RI. TN. UT. VA. WA. WV., Buffalo, NY,
Wash. DC)
ËCorrectional Packages
ËBoiler Descaling Pump Kit (107142)
ËWater Filters
ËRear as Connection (R T)
Short Form Specifications
Shown with optional
Electronic Timer
Cle eland Classic Series
TWO COMPARTMENT, PRESSURELESS
GAS FIRED STEAM GENERATOR, with NICKELGUARD™
200, 250, 00M BTU, 6” WIDE CABINET BASE DESIGN
CONVECTION
STEAMERS
1
0
0
%
5
Y
e
a
r
B
o
i
l
e
r
W
a
r
r
a
n
t
y
N
i
c
k
e
l
G
u
a
r
d
™
SECT. III PA E 11
1007