PRESSURE STEAMERS
Cleveland Standard Features
n5psi Operating Pressure in cooking compartments
n
Mechanical interlock prevents unlatching door while compartment
is pressurized
nTimers, one per compartment, are mechanical style with
audible signal
nThermostatic Trap vents cooking compartment automatically
nSteam Inlet Valves and Exhaust Valves interlocked for
synchronous action
n8psi Compartment Safety Valve
nCapacity per compartment for eight, 12” x 20” x 2 1/2” deep
Cafeteria Pans, or four, 18” x 26” Bun Pans
nHeavy Duty, free floating, cast aluminum compartment doors
nCompartment Door Hinges have adjustable hinge pins and
self-lubricating bushings
nDoor Gasket replaceable without tools
nPressure Gauge for compartment Operating Pressure
nCompartment Slide Racks are removable without tools, for
easy cleaning
nType 430 Stainless Steel: external enclosure, Table Top and
eight gauge plate cooking compartments
nModular Cabinet Base with Hinged Doors
nHigh efficiency Electric Steam Generator with Automatic
Water Fill on start-up
nAutomatic Water Level Control System with Low Water Power
Cut-offCircuit
nSteam Generator equipped with High-limit Pressure Safety
Switch and Safety Valve
n
Automatic Steam Generator (boiler) Blowdown allows intermittent
control, complete with additional Manual Drain Valve
nSingle cold water Connection (no hot water required)
n6” Stainless Steel Legs with level adjustment and flanged feet
pSecondary Low Water Cut-Off, factory installed (CALS)
(Required for AZ. AR. CA. CO. CT.DE. FL. GA. HI. IL. IA. KS. MD. MA. MI. MN.
MT. NE. NV. NM. NC. OK. OR. PR. RI. TN. UT. VA. WA. WV., Buffalo, NY, Wash.
DC)
nStandard Voltage for Controls, 115 volts, 60 Hz, single phase
nAll major components are serviceable from the front of unit
Options & Accessories
pAutomatic Steam Inlet and Exhaust Operation (AT-2):
includes 60 minute Automatic Timers and Manual Bypass
Shall be _____ Compartments, CLEVELAND, Pressure Steamer,
Model PSM- _____ , Steam Coil Steam Generator, _____ volts, single
phase. Each Cooking Compartment equipped with: 60 Minute Timer;
Pressure Safety Valve: Heavy-duty, free floating Door with Safety
Interlock; and synchronous operating Steam Inlet and Exhaust/Drain
Valves. Solid State Controls operate Water Level and Steam
Generator (boiler) Safety Functions. Automatic Steam Generator
(boiler) Blowdown with additional Manual Drain Valve.
pPressure Reducing Valve for 50 to 120 psi steam pressure
(PRV)
pMoisture Separator for steam supply (MS)
pStainless Steel base Frame (FSS)
pSpecial Compartment Slide Racks
p12” x 20” Cafeteria Pans 1”, 2 1/2”, 4” or 6” deep
pIntermediate Pull-Out Shelf (POS)
pSpray Head with flexible Hose (SH)
pWater Filters
pRear Gas Connection (RGT)
ShortFormSpecifications
PRESSURE STEAMERS
2OR 3 COMPARTMENTS
STEAM COIL GENERATOR
36” WIDE CABINET BASE
MODELS:2Compartments 3 Compartments
cPSM-2 cPSM-3
SECT. VI PAGE 5
0707