CAUTION
1. Remove the rubber cap on the backside of the motor
handpiece body with slotted bit screw driver and insert the
connection cord clip (g. 1).
2. Mount CanalPro CL Head to the motor handpiece. Pull out
the head straightly when removing/replacing the head.
3. Insert the connection cord into the slit of the connection
cord clip. Adjust the tension of the connection cord between
the head and the connection cord clip not to be slack (g. 2)
4. Connect the CanalPro CL Head connection cord with the clip
of the apex locator (g. 3).
5. Insert the endodontic le in the
CanalPro CL Head. Slightly turn the le
until it engages with the lock
mechanism (g. 4). Push it inward to
click (g. 5)
Removing the le:
Push the push-button with a thumb and remove the le
(g. 6)
Read this Operation Manual carefully before use for safety and le for future reference.
1. Mounting procedure
1. Entfernen Sie die Gummiabdeckung an der Rückseite des
Motorhandstücks mit einem Schlitzschraubenzieher und
legen Sie den Clip des Verbindungskabels ein (Abb. 1).
2. Montieren Sie den CanalPro CL Kopf auf dem
Motorhandstück. Ziehen Sie den Kpof gerade heraus, wenn
Sie ihn entfernen/austauschen.
3. Führen Sie das Verbindungskabel in den Schlitz des
Verbindungskabel-Clips ein. Passen Sie die Spannung des
Verbindungskabels zwischen Kopf und
Verbindungskabel-Clip so an, dass dieses stra sitzt (Abb. 2).
4. Verbinden Sie die das Verbindungskabel des CanalPro CL
Kopfes mit dem Clip de Apexlokators (Abb. 3).
5. Setzen Sie die Endo-Feile in den
CanalPro CL Kopf ein. Drehen Sie die
Feile leicht, bis Sie im
Haltemechanismus einrastet (Abb. 4).
Drücken Sie sie vollends in den
Haltemechanismus (Abb. 5).
Feile entfernen:
Drücken Sie den Druckknopf mit einem Daumen und ziehen
Sie die Feile heraus (Abb. 6)
Lesen Sie diese Gebrauchsanweisung sorgfältig durch und bewahren Sie sie gut auf.
1. Anbringen des Kopfes
6. Slide the le clip holder to the head direction in order to
establish a contact between the endodontic le and the le
clip (g. 8).
6. Schieben Sie den Feilenclip-Halter nach oben, um einen
Kontakt zwischen der Feile und dem Feilenclip-Halter
herzustellen (Abb. 8)
After the le is locked in place, slightly pull out the le to
make sure the le is locked (g. 7).
VORSICHT
Wenn die Feile im Haltemechanismus eingerastet ist, ziehen
Sie leicht daran um sicherzustellen, dass die Feile sicher sitzt
(Abb. 7).
CAUTION
• Be sure that the endodontic le and the connection cord end have
conduction of electricity before starting to probe the root canal.
• Slide back the le clip holder to motor direction when replacing the
endodontic le and/or when not using the apex locator function.
• Do not bend the le clip.
VORSICHT
• Stellen Sie sicher, dass Feile und das Verbindungskabel elektrische
Konduktion haben, bevor Sie mit der Wurzelkanalmessung beginnen.
• Schieben Sie den Feilenclip-Halter in Richtung des Motor-Handstücks, wenn
Sie die Feile ersetzen und/oder Sie die Wurzelkanal-
Längenmessungsfunktion nicht nutzen wollen.
• Den Feilenclip-Halter nicht verbiegen.
Contra Angle 16:1 AL
OPERATION MANUAL
Contra Angle 16:1 AL
GEBRAUCHSINFORMATION
ENGLISH DEUTSCH
OM-CZ491E
1
2
3
6
7
8
54
Supply PANA SPRAY plus after each use and/or before each autoclaving cycle.
PANA SPRAY plus
Screw the F-type spray nozzle onto the PANA SPRAY plus
nozzle. Insert the F-type spray nozzle into the rear part of
CanalPro CL Head and lubricate by pushing the spray can
button the head for 2-3 seconds (g. 10).
2. Lubrication
Schmieren Sie mit PANA SPRAY plus nach jeder Verwendung und/oder vor
jedem Autoklavieren.
PANA SPRAY plus
Schrauben Sie die F-Typ Spraydüse auf die PANA SPRAY plus
Düse. Führen Sie die F-Typ Spraydüse in den hinteren Teil
des CanalPro CL Kopf und schmieren Sie durch Betätigung
des Druckknopfs an der Spraydose für 2-3 Sekunden
(Abb. 10).
2. Schmierung
Coltène/Whaledent recommends steam autoclaving. Sterilization of CanalPro CL
Head is required after each patient as described below.
Autoclave procedure
1. Scrub dirt and debris from the CanalPro CL Head and wipe clean with
alcohol-immersed cotton swab or cloth. Do not use a wire brush.
2. Lubricate with PANA SPRAY plus. (refer to 2. Lubrication).
3. Place in an autoclave pouch. Seal the pouch.
4. Autoclavable up to max. 135°C
5. Keep the CanalPro CL Head in the autoclave pouch to keep it clean until
you use it.
We recommend the use of class B or class S autoclaves for sterilization.
B-class autoclave: min. 4min. at 134°C
S-class autoclave: min. 10min. at 134°C
B/S-class autoclave: min. 60min. at 121°C
3. Sterilization
Coltène/Whaledent empehlt Dampfsterilisation. Die Sterilisation des CanalPro
CL Kopfs sollte nach jedem Patienten wie nachfolgend beschrieben
durchgeführt werden.
Vorgehen bei der Sterilisation
1. Verschmutzungen und Gewebereste mit einem ggf. in Alkohol getränkten
Tuch abwischen. Keine Drahtbürste verwenden
2. Mit PANA SPRAY plus schmieren (sh. 2. Schmierung)
3. In einen Autoklavierbeutel geben. Beutel versiegeln.
4. Autoklavierbar bis zu max. 135°C
5. CanalPro CL Kopf im Autoklavierbeutel belassen, um ihn bis zur
Verwendung sauber zu halten.
Wir empfehlen die Verwendung eines Klasse B oder Klasse S Autoklaven für die
Sterilisation.
B-Klasse Autoklav: min. 4min. bei 134°C
S-Klasse Autoklav: min. 10min. bei 134°C
B/S-Klasse Autoklav: min. 60min. bei 121°C
3. Sterilisation
Connecting/Disconnecting the cord
(1) Connecting (g. 9)
1. Insert the cord mounting pin at the end of the cord into
the hole on the le clip Holder. The cord should be at
right angle to the body.
2. Rotate the cord 90° until the cord seats correctly.
(2) Disconnecting
Rotate back the cord in the opposite direction and remove
it.
Kabel verbinden/trennen
(1) Kabel verbinden (Abb. 9)
1. Führen Sie den Kabelpin am Ende des Kabels in das Loch
des Feilenclip-Halters. Das Kabel sollte in diesem Moment
rechtwinklig zum Instrumentenkörper stehen.
2. Drehen Sie das Kabel um 90°, bis es korrekt sitzt
(2) Kabel lösen
Drehen Sie das Kabel wieder zurück und entfernen Sie es.
CAUTION
Do not use high force to pull the connection.
VORSICHT
Wenden Sie beim Lösen der Verbindung keine zu große Kraft an.
CAUTION
• Before mounting the lubricated CanalPro CL Head to the motor handpiece,
wipe o excess oil. Place or lean it in an upright position for gravity draining.
Mount it after excess oil has been completely drained.
• Hold the CanalPro CL Head securely to prevent it from ying o by the spray
can pressure.
• Hold the spray can upright.
VORSICHT
• Wischen Sie überschüssiges Öl ab, bevor Sie den geschmierten CanalPro CL
Kopf wieder am Motorhandstück anbringen. Bringen Sie den Kopf in eine
aufrechte Position, um überschüssiges Öl ablaufen zu lassen. Montieren Sie
den Kopf, wenn überschüssiges Öl komplett abgelaufen ist.
• Halten Sie den CanalPro CL Kopf gut fest, wenn Sie mit der Spraydose
pegen, um ein unbeabsichtigtes Abiegen des Kopfs zu vermeiden.
• Halten Sie die Spraydose aufrecht.
CAUTION
• Cord clip is not autoclavable.
• Do not wipe with, or clean or immerse in high acid water or sterilizing
solutions.
VORSICHT
• Der Kabel-Clip ist nicht autoklavierbar.
• Wischen Sie den Kopf nicht mit stark saurem Wasser oder Sterilisierlösung ab
und tauchen Sie ihn nicht in solche ein.
Coltène/Whaledent GmbH + Co. KG
Raieisenstraße 30
89129 Langenau / Germany
Tel +49 7345 805 0
Fax +49 7345 805 201
info[email protected]
Coltène/Whaledent AG
Feldwiesenstrasse 20
9450 Altstätten / Switzerland
Tel +41 71 757 5300
Fax +41 71 757 5301
info[email protected]
Manufactured for:
Coltène/Whaledent Inc.
235 Ascot Parkway
Cuyahoga Falls, Ohio 44223/USA
www.coltenewhaledent.com
12.03.20 00 N
10
9

Other Coltene Dental Equipment manuals

Coltene CanalPro User manual

Coltene

Coltene CanalPro User manual

Coltene CanalPro Jeni User manual

Coltene

Coltene CanalPro Jeni User manual

Coltene SciCan STATIM B G4+ User manual

Coltene

Coltene SciCan STATIM B G4+ User manual

Coltene STATCLAVE User manual

Coltene

Coltene STATCLAVE User manual

Coltene ParaPost XT P-680T User manual

Coltene

Coltene ParaPost XT P-680T User manual

Coltene SciCan BRAVO G4 User manual

Coltene

Coltene SciCan BRAVO G4 User manual

Coltene ParaPost X Series User manual

Coltene

Coltene ParaPost X Series User manual

Coltene SciCan HYDRIM C61WD G4 User manual

Coltene

Coltene SciCan HYDRIM C61WD G4 User manual

Coltene Coltolux LED User manual

Coltene

Coltene Coltolux LED User manual

Coltene CanalPro Jeni User manual

Coltene

Coltene CanalPro Jeni User manual

Coltene DIATECH Z-Rex Diamond User manual

Coltene

Coltene DIATECH Z-Rex Diamond User manual

Coltene SciCan BRAVO G4 User manual

Coltene

Coltene SciCan BRAVO G4 User manual

Coltene CanalPro Apex Locator Compact User manual

Coltene

Coltene CanalPro Apex Locator Compact User manual

Coltene CanalPro CL2 User manual

Coltene

Coltene CanalPro CL2 User manual

Coltene CanalPro Jeni User manual

Coltene

Coltene CanalPro Jeni User manual

Coltene Coltolux LED User manual

Coltene

Coltene Coltolux LED User manual

Popular Dental Equipment manuals by other brands

Seecode 20338 manual

Seecode

Seecode 20338 manual

Profi Care PC-DC 3031 instruction manual

Profi Care

Profi Care PC-DC 3031 instruction manual

Amanngirrbach Ceramill Base Important note on upgrading

Amanngirrbach

Amanngirrbach Ceramill Base Important note on upgrading

Guilin Woodpecker Medical Instrument Endo Radar Pro instruction manual

Guilin Woodpecker Medical Instrument

Guilin Woodpecker Medical Instrument Endo Radar Pro instruction manual

Satelec Implant Center 2 user manual

Satelec

Satelec Implant Center 2 user manual

VERDER Carbolite Gero CDF 15/1b Installation, operation & maintenance instructions

VERDER

VERDER Carbolite Gero CDF 15/1b Installation, operation & maintenance instructions

DARAY SL730LW Operating & installation manual

DARAY

DARAY SL730LW Operating & installation manual

NSK FX204 Series Operation manual

NSK

NSK FX204 Series Operation manual

Renfert Vario basic 2960-0000 instruction manual

Renfert

Renfert Vario basic 2960-0000 instruction manual

Zimmer 8831-001 Instruction and service manual

Zimmer

Zimmer 8831-001 Instruction and service manual

VHF K5+ Original operating instructions

VHF

VHF K5+ Original operating instructions

Dabi Atlante COBRA CONTRA ANGLE INTRA 32 CA owner's manual

Dabi Atlante

Dabi Atlante COBRA CONTRA ANGLE INTRA 32 CA owner's manual

BesQual E420 user manual

BesQual

BesQual E420 user manual

Bomedent Actor I pro user manual

Bomedent

Bomedent Actor I pro user manual

Dentsply Sirona inEos X5 operating instructions

Dentsply Sirona

Dentsply Sirona inEos X5 operating instructions

Kulzer PALA Palamat Premium Operating	 instruction

Kulzer

Kulzer PALA Palamat Premium Operating instruction

Digiray Fire CR Maintenance Guide

Digiray

Digiray Fire CR Maintenance Guide

Vista Apex phasor user manual

Vista Apex

Vista Apex phasor user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.