Powering the AP with DC Power
The AP can draw power from the Ethernet input as a Class 4
device, providing a maximum of 22W to the system. Alternately,
power can be supplied through a customer-provided 12V DC
power supply (12V DC preferred, 7-20V DC acceptable) that will
connect to a two-pin terminal block. The terminal block is
accessible through a water-ght gland on one end of the unit. The
terminal block connecon has surge and polarity protecon to
protect against inserng the wrong polarity leads into the
terminal block.
NOTE: If both the PoE and DC ports are used, separate cable
glands must be used for each port. Addional cable gland (Part
Number 902-0183-0000) can be be purchased.
NOTE: When both the 12V DC and the 48V PoE power are
acve, the AP will priorize the 12V DC power.
CAUTION! Ensure that the DC power source does not exceed
20V DC.
1. Install the DC power supply as described in the DC Power
Supply Installaon Guide.
2. Connect the DC cord to a DC power source.
3. Verify that the PWR LED is a steady green.
Earth Grounding the AP
CAUTION! Make sure that earth grounding is available and that
it meets local and naonal electrical codes. For addional
lightning protecon, use lightning rods and lightning arrestors.
NOTE: The color coding of ground wires varies by region.
Before compleng this step, check your local wiring standards
for guidance.
Using the factory-supplied ground wire and ground screw and
washer set, connect a good earth ground to the AP chassis ground
point.
CAUTION! The T350se AP includes one 9-mm stainless steel
M6x1 earth ground screw with split lock and at washers.
Make sure that any replacement screw is no longer than 9-mm.
If a screw is longer than 9-mm, it can damage the AP chassis.
FIGURE 12 Connecng a Good Earth Ground to the AP
1. Earth grounding
Installing a USB Dongle
To install a USB dongle (for example, an IoT radio device such as
BLE, 802.15.4, Z-wave, or similar), remove the two 3-mm hex
screws, remove the cap, and insert the dongle into the USB port.
Once installed, replace the cap and the hex screws, and ghten
the screws to 0.79 N.m or 7 in-lbs.
NOTE: If required, a larger USB dongle cap can be purchased
separately. The maximum dimensions of the USB dongle that
can be inserted (with the large USB dongle cap, part #
902-0127-000) are 6 cm x 2 cm x 1.1 cm. The USB port
supports 2.5W.
FIGURE 13 Installing a USB Dongle
Troubleshoong
CAUTION! If required, you can reset the AP to its factory
default sengs by pressing the reset buon located inside the
PoE IN port. Use the p of a pen or a 3-mm at-blade
screwdriver to press the reset buon. Press and hold the reset
buon for 4 seconds or longer to restore to factory defaults.
DO NOT RESET THE AP TO FACTORY DEFAULT SETTINGS UNLESS
SO INSTRUCTED. (Doing this resets the AP IP address to
192.168.0.1.)
NOTE: Aer a reset, you can access the internal AP web
interface using hps://192.168.0.1. Your device must use any
other address from 192.168.0.2 through 192.168.0.254, with
subnet mask 255.255.255.0. The username is super, and the
password is sp-admin.
For More Informaon
For informaon on how to congure and manage the AP, refer to
the RUCKUS Access Point User Guide, available from hps://
support.ruckuswireless.com.
RUCKUS WIRELESS, Inc. is a wholly owned subsidiary of
CommScope, Inc.
© 2021 CommScope, Inc. All rights reserved.
ARRIS, the ARRIS logo, COMMSCOPE, RUCKUS, RUCKUS WIRELESS, the Ruckus
logo, and the Big Dog design are trademarks of CommScope, Inc. and/or its
aliates. Wi-Fi Alliance, Wi-Fi, the Wi-Fi logo, Wi-Fi Cered, the Wi-Fi
CERTIFIED logo, Wi-Fi Protected Access, the Wi-Fi Protected Setup logo, Wi-Fi
Protected Setup, Wi-Fi Mulmedia and WPA2 and WMM are trademarks or
registered trademarks of Wi-Fi Alliance. All other trademarks are the property of
their respecve owners.
Copyright © 2021 CommScope, Inc. All rights reserved. Page 4 of 4
Published November 2021, Part Number 800-72897-001 Rev A