SPECIFICATION FEATURES
08/05/2008 2:32:09 PM
Consult your representative for additional options and finishes.
Specifications and Dimensions subject to change without notice.
TMU_ADH081549
DIMENSIONS
DRILLING PATTERNS
DESCRIPTION
The Streetworks Talon is the most versatile, functionally designed,
universally adaptable outdoor luminaire available. The Talon brings
outstanding performance to walkways, parking lots, roadways, building
areas, and any security lighting application. U.L. listed and CSA certified for
wet locations. IP65 Rated.
Construction
One-piece heavy-wall, die-cast
aluminum construction with
integral reveal channels along top
surface of housing. Internal cast-in
wall separates optical and
electrical chambers allowing
components to operate cooler.
One-piece die-cast aluminum door
frame with integral cast-in gasket
channel seals optical chamber to
an IP65 rating. Stainless steel
latches and hinges allow for
toolless opening and removal of
door frame.
Reflector
Choice of 14 high efficiency optical
systems utilizing horizontal and
vertical lamp orientations. Optional
high efficiency segmented optical
systems constructed of premium
95% reflective anodized aluminum
sheet. Optical segments are rigidly
mounted inside a thick gauge
aluminum housing for superior
protection. All segment faces are
clean of rivet heads, tabs or other
means of attachment which may
cause streaking in the light
distribution.
Standard with mogul-base socket
for HPS and 100-400W MH.
Standard with medium-base socket
for 70W MH and below. All optical
modules feature quick disconnect
wiring plugs and are field rotatable
in 90° increments.
Electrical
Offered standard with ballast and
related electrical componentry
hard mounted to die-cast housing
details for optimal heat transfer
and operating efficiency. Optional
galvanized steel swing-down
power tray with integral handle.
Electrical disconnects allow tray to
be completely removed from the
housing providing ample hand and
tool room for attachment of fixture
during installation.
Mounting
Extruded 8" aluminum arm
includes internal bolt guides
allowing for easy positioning of
fixture during installation to pole
or wall surface. Standard single
carton packaging of housing,
square pole arm and round pole
adapter for contractor friendly
arrival of product on site.
Finish
Housing and arm finished in a 5
stage premium TGIC polyester
powder coat paint, 2.5 mil nominal
thickness for superior protection
against fade and wear. Standard
colors include black, bronze, grey,
white, dark platinum, and graphite
metallic.
TMU
TALON MEDIUM
70-400W
High Pressure Sodium
Pulse Start Metal Halide
Super Metal Halide
Metal Halide
AREA LUMINAIRE
E N E R G Y D ATA
Hi-Reactance Ballast Input Watts
70W HPS HPF (95 Watts)
100W HPS HPF (130 Watts)
150W HPS HPF (190 Watts)
150W MH HPF (185 Watts)
CWI Ballast Input Watts
250W HPS HPF (300 Watts)
CWA Ballast Input Watts
175W MH HPF (210 Watts)
200W MP HPF (240 Watts)
250W MH HPF (295 Watts)
320W MP HPF (365 Watts)
400W MP HPF (448 Watts)
400W MH HPF (455 Watts)
400W HPS HPF (465 Watts)
E P A
Effective Projected Area: (Sq. Ft.)
Recessed Door w/o Arm: 0.79
Deep Door w/o Arm: 1.02
8" Arm: 0.43
S H I P P I N G D ATA
Approximate Net Weight:
Recessed Door 47 lbs. (21.79 kgs.)
Deep Door 52 lbs. (23.63 kgs.)
S
Y
S
T
E
M
S
C
E
R
T
I
F
I
E
D
LAMP TYPE WATTAGE
Metal Halide
175, 250, 400W
Pulse Start Metal Halide 70, 100, 150, 175, 200, 250, 320, 350, 400W
Super Metal Halide 175, 250, 400W
High Pressure Sodium 70, 100, 150, 250, 400W
11 7/8"
[302mm]
8"
[203mm]
1 3/4"
[45mm]
16 1/4" [412mm]
23 1/4" [590mm] 8"
[203mm]
T Y P E “ M ” WA L L M O U N T
3/4" [20mm]
dia. hole
(2) 5/8" [16mm]
dia. holes
4 7/8" [124mm]
2 7/16" [124mm]
2 5/16"
[59mm]
12"
[305mm]
4 7/8"
[124mm]
9/16" [14mm]
Dia. Hole (4)
6 1/2"
[165mm]
8"
[203mm]
10 1/2"
[267mm]
STREETWORKS™
Streetworks • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801 08/05/2008 2:32:09 PM
Specifications and Dimensions subject to change without notice.
TMU_ADH081549
ORDERING INFORMATION
TALON MEDIUM
TMU
SAMPLE NUMBER: TMU40SWW3SF
TMU
Product Family 1
TMU=Talon Site
Medium
Lamp Wattage 2
70=70W
10=100W
15=150W
17=175W
20=200W
25=250W
32=320W 3, 4
35=350W 3, 4
40=400W 4
24=250/400W wired 250W
42=250/400W wired 400W
Distribution
Horizontal Lamp
2F=Type II Formed
2S=Type II Segmented
3F=Type III Formed
3S=Type III Segmented
4F=Type IV Formed
4S=Type IV Segmented
5F=Type V Formed
5S=Type V Segmented
SL=Spill Light Eliminator
AF=Automotive Front
Row
Vertical Lamp
3V=Type III Vertical 5
4V=Type IV Vertical 5
AR=Area Round 5
AS=Area Square 5
Lens Type
F=Flat Glass
S=Sag Glass
Options (add as suffix/must be
ordered in alphanumeric order)
1=Single Fuse
[120, 277 or 347V] 6
2=Double Fuse
[208, 240 or 480V] 6
3=Three Place Terminal Block
4=NEMA Twistlock Photocontrol
Receptacle
B=Internal House-side Shield 7
DD=Deep Door
DM=Direct Mount for Round or
Square Pole
DW=Direct Wall Mount Kit
E=Quartz Restrike w/Delay
[Also Strikes at Cold Start] 8
H=Plug-in Starter Receptacle
HL=Hi/Low Dimming 9
L=Lamp Included
MS=External Mast Arm Adapter
P=Button Type Photocontrol
[120, 208, 240 or 277V] 6
Q=Quartz Restrike
[Hot Restrike Only] 8
R=Removable Power Tray
U=U.L. Listed
V=Polycarbonate Vandal Shield
WM=Wall Bracket with 8" Arm
Accessories
(order separately/replace XX with color designation)
OA/RA1016=NEMA Photocontrol (105-285V)
OA/RA1027=NEMA Photocontrol (480V)
OA/RA1201=NEMA Photocontrol (347V)
OA/RA1013=Shorting Cap
MA1010-XX=Single Tenon Adapter for 3 1/2" O.D. Tenon
MA1011-XX=2 @ 180° Tenon Adapter for 3 1/2" O.D. Tenon
MA1012-XX=3 @ 120° Tenon Adapter for 3 1/2" O.D. Tenon
MA1013-XX=4 @ 90° Tenon Adapter for 3 1/2" O.D. Tenon
MA1014-XX=2 @ 90° Tenon Adapter for 3 1/2" O.D. Tenon
MA1015-XX=2 @ 120° Tenon Adapter for 3 1/2" O.D. Tenon
MA1016-XX=3 @ 90° Tenon Adapter for 3 1/2" O.D. Tenon
MA1017-XX=Single Tenon Adapter for 2 3/8" O.D. Tenon
MA1018-XX=2 @ 180° Tenon Adapter for 2 3/8" O.D. Tenon
MA1019-XX=3 @ 120° Tenon Adapter for 2 3/8" O.D. Tenon
MA1045-XX=4 @ 90° Tenon Adapter for 2 3/8" O.D. Tenon
MA1048-XX=2 @ 90° Tenon Adapter for 2 3/8" O.D. Tenon
MA1049-XX=3 @ 90° Tenon Adapter for 2 3/8" O.D. Tenon
MA1213-XX=External House-side Shield Kit [EPA=0.38] 7
NOTES: 1 8" arm and round pole adapter included with fixture. 2Standard with mogul-base socket for HPS and 100-400W MH. Standard with medium-base socket for 70W MH. 3320/350W Pulse Start Metal Halide lamp
only. 4Requires reduced envelope lamp. 5Vertical lamp optics ship standard with deep door. Flat glass not available for 250W—400W. 6Must specify voltage. 7House-side shield not available on 5S, 5F, AS, AR
and SL optics. 8Quartz options not available with SL and AF optics. 9Requires vertical lamp orientation. Provides 24V low voltage leads used in dimming controls. 10 Specifications and dimensions subject to
change without notice.
Lamp Type
S=High Pressure Sodium
R=Super Metal Halide
M=Metal Halide
P=Pulse Start Metal Halide
Ballast Type
C=CWI
H=Reac./HPF
K=10KV CWA
N=Hi. Reac./NPF
P=Hi. Reac./HPF
R=Reac./NPF
W=CWA
Colors (add as suffix/
must specify)
WH=White
BK=Black
AP=Grey
BZ=Bronze
DP=Dark Platinum
GM=Graphite Metallic
Voltage
2=120V
0=208V
4=240V
7=277V
8=480V
9=347V
N=Multi-Tap wired 277V
W=Multi-Tap wired 120V
V=Multi-Tap wired 240V
Streetworks • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801 08/05/2008 2:32:09 PM
Specifications and Dimensions subject to change without notice.
TMU_ADH081549
PHOTOMETRICS [Complete IES files available at www.cooperlighting.com]
MOUNTING CONFIGURATIONS
Footcandle Table
Select mounting height and read across for
footcandle values of each isofootcandle line.
Distance in units of mounting height.
Mounting Footcandle Values for
Height Isofootcandle Lines
A B C D E
175W [3V/AS]
15' 1.70 0.85 0.34 0.17 --
20' 1.00 0.50 0.20 0.10 --
25' 0.64 0.32 0.13 0.06 --
250W [SL]/400W [3S]
20' 2.00 1.00 0.50 0.20 0.10
25' 1.28 0.64 0.32 0.13 0.06
30' 0.88 0.44 0.22 0.09 0.04
A B C D
TMU17MXX3VF
175-Watt MH
14,000-Lumen Clear Lamp
Type III Vertical
Flat Glass
A B C D
TMU17MXXASF
175-Watt MH
14,000-Lumen Clear Lamp
Area Square
Flat Glass
A B C D E
TMU25MXXSLF
250-Watt MH
20,500-Lumen Clear Lamp
Spill Light Eliminator
Flat Glass
A B C D E
TMU40MXX3SF
400-Watt MH
36,000-Lumen Clear Lamp
Type III Segmented
Flat Glass
Footcandle Table
Select mounting height and read across for
footcandle values of each isofootcandle line.
Distance in units of mounting height.
Mounting Footcandle Values for
Height Isofootcandle Lines
A B C D E
400W [3V/4V/5S/AR]
20' 3.00 1.50 0.75 0.30 0.15
25' 2.00 1.00 0.50 0.20 0.10
30' 1.38 0.69 0.34 0.13 0.06
A B C D E
TMU40MXX3VS
400-Watt MH
36,000-Lumen Clear Lamp
Type III Vertical
Sag Glass
A B C D E
TMU40MXX4VS
400-Watt MH
36,000-Lumen Clear Lamp
Type IV Automotive Perimeter
Sag Glass
A B C D E
TMU40MXX5SF
400-Watt MH
36,000-Lumen Clear Lamp
Type V Segmented
Flat Glass
A B C D E
TMU40MXXARS
400-Watt MH
36,000-Lumen Clear Lamp
Area Round
Sag Glass
Wall Mount Arm Mount Single
E.P.A.
TMU
Recessed Door 1.22
Deep Door 1.45
Arm Mount 2 @ 180°
E.P.A.
TMU
Recessed Door 2.44
Deep Door 2.90
Arm Mount 2 @ 90°
E.P.A.
TMU
Recessed Door 2.44
Deep Door 2.90
Arm Mount 3 @ 120°
E.P.A.
TMU
Recessed Door 3.23
Deep Door 3.92
Arm Mount 3 @ 90°
E.P.A.
TMU
Recessed Door 3.23
Deep Door 3.92
Arm Mount 4 @ 90°
E.P.A.
TMU
Recessed Door 3.63
Deep Door 4.43

Other Cooper Lighting Landscape Lighting manuals

Cooper Lighting ACORN ACN-2 User manual

Cooper Lighting

Cooper Lighting ACORN ACN-2 User manual

Cooper Lighting Lumiere Aspen 1900-AA User manual

Cooper Lighting

Cooper Lighting Lumiere Aspen 1900-AA User manual

Cooper Lighting MCGRAW-EDISON GAR User manual

Cooper Lighting

Cooper Lighting MCGRAW-EDISON GAR User manual

Cooper Lighting Galleria Round 150-1000W User manual

Cooper Lighting

Cooper Lighting Galleria Round 150-1000W User manual

Cooper Lighting Breckenridge MPB50SR255 User manual

Cooper Lighting

Cooper Lighting Breckenridge MPB50SR255 User manual

Cooper Lighting Lexington LXF70SR2554 User manual

Cooper Lighting

Cooper Lighting Lexington LXF70SR2554 User manual

Cooper Lighting MEM17MWW2SXSNBK User manual

Cooper Lighting

Cooper Lighting MEM17MWW2SXSNBK User manual

Cooper Lighting MPN50SR255 User manual

Cooper Lighting

Cooper Lighting MPN50SR255 User manual

Cooper Lighting OVZ50SR22E4 User manual

Cooper Lighting

Cooper Lighting OVZ50SR22E4 User manual

Cooper Lighting CMS185, CMS185W User manual

Cooper Lighting

Cooper Lighting CMS185, CMS185W User manual

Cooper Lighting C CIRRUS CAS17MWW3D User manual

Cooper Lighting

Cooper Lighting C CIRRUS CAS17MWW3D User manual

Cooper Lighting CX Series User manual

Cooper Lighting

Cooper Lighting CX Series User manual

Cooper Lighting ORL15SWWXX User manual

Cooper Lighting

Cooper Lighting ORL15SWWXX User manual

Cooper Lighting Manchester 70-175W User manual

Cooper Lighting

Cooper Lighting Manchester 70-175W User manual

Cooper Lighting High Mast HMC40SC23E User manual

Cooper Lighting

Cooper Lighting High Mast HMC40SC23E User manual

Cooper Lighting Tribute User manual

Cooper Lighting

Cooper Lighting Tribute User manual

Cooper Lighting N175MV User manual

Cooper Lighting

Cooper Lighting N175MV User manual

Cooper Lighting Envoy User manual

Cooper Lighting

Cooper Lighting Envoy User manual

Cooper Lighting Breckenridge 50-250W User manual

Cooper Lighting

Cooper Lighting Breckenridge 50-250W User manual

Cooper Lighting Pole Mount Icon User manual

Cooper Lighting

Cooper Lighting Pole Mount Icon User manual

Cooper Lighting Avenue ARC25MWW5552 User manual

Cooper Lighting

Cooper Lighting Avenue ARC25MWW5552 User manual

Cooper Lighting ADH080747 Guide

Cooper Lighting

Cooper Lighting ADH080747 Guide

Cooper Lighting Acorn ANE50SR2554 User manual

Cooper Lighting

Cooper Lighting Acorn ANE50SR2554 User manual

Cooper Lighting FTS User manual

Cooper Lighting

Cooper Lighting FTS User manual

Popular Landscape Lighting manuals by other brands

COLORKINETICS BCP463 installation instructions

COLORKINETICS

COLORKINETICS BCP463 installation instructions

HAMPTON BAY HD28784 Use and care guide

HAMPTON BAY

HAMPTON BAY HD28784 Use and care guide

easymaxx LPS-GD-05RG instruction manual

easymaxx

easymaxx LPS-GD-05RG instruction manual

LIGMAN LE-40722-S installation manual

LIGMAN

LIGMAN LE-40722-S installation manual

LightPro Juno 2 193S user manual

LightPro

LightPro Juno 2 193S user manual

AMP AFL-4033 Installation & maintenance guide

AMP

AMP AFL-4033 Installation & maintenance guide

iGuzzini Light Up Earth E127 manual

iGuzzini

iGuzzini Light Up Earth E127 manual

Volt RGBW Max All-Star VAL-2045-ABK installation instructions

Volt

Volt RGBW Max All-Star VAL-2045-ABK installation instructions

Volt VHS-6719-BBZ installation instructions

Volt

Volt VHS-6719-BBZ installation instructions

LIGMAN NYB-80345 installation manual

LIGMAN

LIGMAN NYB-80345 installation manual

Volt VAL-1004-4-BBZ installation instructions

Volt

Volt VAL-1004-4-BBZ installation instructions

LIGMAN MASK 2 installation manual

LIGMAN

LIGMAN MASK 2 installation manual

LIGMAN UTAH 4 UT-50565 installation manual

LIGMAN

LIGMAN UTAH 4 UT-50565 installation manual

Volt VFL-450X-BBZ installation instructions

Volt

Volt VFL-450X-BBZ installation instructions

Catellani & Smith Syphaduepassi Assembly instructions

Catellani & Smith

Catellani & Smith Syphaduepassi Assembly instructions

LIGMAN EU-10016-2 installation manual

LIGMAN

LIGMAN EU-10016-2 installation manual

WE-EF ESC100 LED Series Installation and maintenance instructions

WE-EF

WE-EF ESC100 LED Series Installation and maintenance instructions

LIGMAN FORREY 6 installation manual

LIGMAN

LIGMAN FORREY 6 installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.