manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. CTC Union
  6. •
  7. Switch
  8. •
  9. CTC Union IFS?402F User manual

CTC Union IFS?402F User manual


























CTCUnionTechnologiesCo.,Ltd.
FarEasternViennaTechnologyCenter
(NeihuTechnologyPark)
8F,No.60ZhouziSt.,NeihuDistrict,Taipei114
Taiwan

T+886‐2‐26591021
F+886‐2‐26590237
E[email protected]







©2013CTCUnionTechnologiesCo.,Ltd.
Alltrademarksarethepropertyoftheirrespectiveowners.
Technicalinformationinthisdocumentissubjecttochangewithoutnotice.




Introduction
IFS‐402F/402F‐Emodelsare4‐port10/100Base‐T(X)Ethernet
plus2‐port100Base‐FXswitchesthatprovidestableandreliable
Ethernettransmission.HousedinruggedDINrailorwall
mountableenclosures,theseswitchesaredesignedforharsh
environments,suchasindustrialnetworkingandintelligent
transportationsystems(ITS)andarealsosuitableformany
militaryandutilitymarketapplicationswhereenvironmental
conditionsexceedcommercialproductspecifications.Standard
operatingtemperaturerangemodels(0to60°C)andwide
operatingtemperaturerangemodels(‐40to75°C)fulfillthe
specialneedsofindustrialautomationapplications.

Features
•RedundantdualDCinputs12/24/48VDC
•IP30ruggedmetalhousing
•Widetemperaturerange‐40~75C(IFS‐402F‐E)
•IndustrialgradeEMScertification
•DIPswitchenable/disablebroadcaststormfilter
•UL508,CE,FCC,EN50121‐4Railtraffic

Specifications
EthernetInterface
•Connector:RJ‐45(shielded)
•4‐ports
•AutoMDI/MDI‐X
•Speed:10/100Base‐TX(Auto)
•Duplex:Full/Half(Auto‐negotiationperIEEE802.3u)
•SupportsIEEE802.3xFlowControl
•Store&ForwardSwitch
•SwitchingFabric:1.2Gbps
•Packetbuffer:448kb
•Packetsize:64~1536bytes
•Standards:IEEE802.3,802.3u,802.3x
•2KMACtable
•MTU:64~1536bytes
•BroadcastStormprotection(enable/disablebyDIP)







QuickInstallationGuide


IFS‐402F
IFS‐402F‐E
IndustrialGradeFastEthernetSwitches























TodownloadthisQIGoramorecompleteusermanual,pleasevisit
http://www.ctcu.com/Industrial/





[email protected]




Specifications(cont.)
OpticalEthernetInterface
•100Base‐FX,2‐ports
•OptionsforSCorSTconnectors
•Multimode(2km)50/125um,62.5/125um
•Singlemode(30or50km)9/125um
•Wavelength:1310nm(S/MorM/M)
•BiDioption(20km)forsinglemode,singlefiber
Power
•Absoluterange:9.6~60VDC
•Reversepolarityprotection:Yes
•Dualpowerinputs:Yes
•Connector:removableterminalblock
•Consumption:0.09A@48VDC,4.32Watts

Mechanical
•Water&DustProof:IP30Protection
•Dimensions:106x39x142mm(DxWxH)
•Mounting:DIN‐Rail,WallMount(kitsincluded)
•Weight:635g

Environmental
•OperatingTemperature:
•0°C~60°C,‐40°C~75°C(widetemp.for*‐E)
•StorageTemperature:‐40°C~85°C
•Humidity:5~95%(non‐condensing)

Certifications
•EMI:FCCPart15subBclassA,EN55022ClassA
•EMS:(ElectomagneticSusceptibility)
•EN61000‐4‐2(ESD)Level3,CriteriaB
•EN61000‐4‐3(RS)Level3,CriteriaA
•EN61000‐4‐4(Burst)Level3,CriteriaA
•EN61000‐4‐5(Surge)Level3,CriteriaB
•EN61000‐4‐6(CS)Level3,CriteriaA
•EN61000‐4‐8(MagneticField)Level3,CriteriaA
•Safety:UL508(pending)
•RailwayTraffic:EN50121‐4
•Shock:EN60068‐2‐27Freefall:EN60068‐2‐32
•Vibration:EN60068‐2‐6
•MTBF:509883hours

[email protected]www.ctcu.comV1.0
 
 
ConnectorsInstallation
IFS‐402F/402F‐EcomeswithbothwallmountandDINrail
hardwarebrackets.WheninstallingtheDINrailbracket,besure
tocorrectlyaligntheorientationpin.


 
 
 


IFS‐402F4‐port10/100plus2‐portFiberFastEthernetswitch 
 
The4‐TP(twistedpair)LANconnectionsusesshieldedRJ‐45
whichsupportAutoMDI/MDI‐X,whiletheopticalconnectionsuse
SCorSTopticalconnectionsformultimodeorsinglemodefiber
dependingonthemodel.




 
Power,AlarmandDIPswitchDINRailWallMount
 
 
IFS‐402F/402F‐EwithDINRailbrackethasasteelspringinthe
upperrailofthebracket.Thisspringiscompressedformounting
andun‐mountingbyapplyingdownwardforce.







Aremovableterminalblockprovidesbothpowerandalarm
connections.Powercanbeprovidedthroughthedualinputsfrom
separatesources.Oneelectricalrelaycanbewiredintoanalarm
circuit.TherelayisconnectedasNormallyClosed(NC).




IFS‐402F/402F‐Eusesa2‐poleDIPswitchforconfiguration,with
eachpoleoftheswitchhavingthefollowingfunctions:


 
1.PWRAlarm:When'On'thisswitchwilldisablealarmrelayand
LEDifthereisapowerfailureinonesupply.Ifonlyconnectingto
asinglepowersource,placethisswitch'On'todisablealarm.



 
2.BSP:When'On'thisswitchwilldisablethebroadcaststorm
protectionfeaturewhichisenabledbydefault.


mountingun‐mounting
 
 
 
LEDIndicatorsNotes:
IFS‐402FandIFS‐402F‐EhaveLEDsonthefrontfacethatreport
theconditionofpower,alarm,Fiberlink,LANlinkandspeed.




PWR
1 PWR2 Fault LINK/
ACT
100
Fiber 1 Fiber 2








PWR1:ThisgreenLEDwilllightifpowerisconnectedandactive
atthePWR1terminalconnection.

PWR2:ThisgreenLEDwilllightifpowerisconnectedandactive
atthePWR2terminalconnection.

Fault:ThisamberLEDwilllightifoneofthepowerinputshas
faultconditionandaslongasDIPsw#1isOFF.

Fiber1:ThisgreenLEDwilllightwhenthefiber1porthasan
opticallinkandwillflashwhenthereisEthernettraffic.

Fiber2:ThisgreenLEDwilllightwhenthefiber2porthasan
opticallinkandwillflashwhenthereisEthernettraffic.

100:ThisyellowLEDwilllightwhentheLANconnectedspeedis
100Mandwillremainoffiftheconnectedspeedis10M.

LINK/ACT:ThisgreenLEDwilllightwhentheLANporthasalink
andwillflashwhenthereisEthernettraffic.


[email protected]www.ctcu.com

This manual suits for next models

1

Other CTC Union Switch manuals

CTC Union ITP-1204GTM-12PHE User manual

CTC Union

CTC Union ITP-1204GTM-12PHE User manual

CTC Union IFS-402GSM User manual

CTC Union

CTC Union IFS-402GSM User manual

CTC Union GSW-1005MS User manual

CTC Union

CTC Union GSW-1005MS User manual

CTC Union SB282 Series User manual

CTC Union

CTC Union SB282 Series User manual

CTC Union IGS-1608SM-SE User manual

CTC Union

CTC Union IGS-1608SM-SE User manual

CTC Union IGS+803SM-8PH User manual

CTC Union

CTC Union IGS+803SM-8PH User manual

CTC Union IGS-401F User manual

CTC Union

CTC Union IGS-401F User manual

CTC Union IGS-2408SM-24PH User manual

CTC Union

CTC Union IGS-2408SM-24PH User manual

CTC Union VRM01/24 User manual

CTC Union

CTC Union VRM01/24 User manual

CTC Union SB152 Series User manual

CTC Union

CTC Union SB152 Series User manual

CTC Union GSW-3208M1 User manual

CTC Union

CTC Union GSW-3208M1 User manual

CTC Union TSB1000 Series User manual

CTC Union

CTC Union TSB1000 Series User manual

CTC Union SB142 User manual

CTC Union

CTC Union SB142 User manual

CTC Union ITP-500 User manual

CTC Union

CTC Union ITP-500 User manual

CTC Union SB262 Series User manual

CTC Union

CTC Union SB262 Series User manual

CTC Union JB330 Series User manual

CTC Union

CTC Union JB330 Series User manual

CTC Union JB130 Series User manual

CTC Union

CTC Union JB130 Series User manual

CTC Union ITP-G800SM-8PH24 User manual

CTC Union

CTC Union ITP-G800SM-8PH24 User manual

CTC Union FSW-2104W User manual

CTC Union

CTC Union FSW-2104W User manual

CTC Union IGS?401F?4PH24 User manual

CTC Union

CTC Union IGS?401F?4PH24 User manual

CTC Union FRM220A-1000EAS/X User manual

CTC Union

CTC Union FRM220A-1000EAS/X User manual

CTC Union IGS?401F?4PH24 User manual

CTC Union

CTC Union IGS?401F?4PH24 User manual

CTC Union SB202 Series User manual

CTC Union

CTC Union SB202 Series User manual

CTC Union MSW-4424C Series User manual

CTC Union

CTC Union MSW-4424C Series User manual

Popular Switch manuals by other brands

QNO QMS1024G user manual

QNO

QNO QMS1024G user manual

Mellanox Technologies InfiniScale III M2401G 20Gb/s InfiniBand user manual

Mellanox Technologies

Mellanox Technologies InfiniScale III M2401G 20Gb/s InfiniBand user manual

Kramer VP-719xl user manual

Kramer

Kramer VP-719xl user manual

ZyXEL Communications XGS-4528F Specifications

ZyXEL Communications

ZyXEL Communications XGS-4528F Specifications

Raritan PC-Share Installation and operation

Raritan

Raritan PC-Share Installation and operation

AJAX Hub 2 quick start guide

AJAX

AJAX Hub 2 quick start guide

foxunhd FX-SW07 operating instructions

foxunhd

foxunhd FX-SW07 operating instructions

CTS SWH-2109FX user guide

CTS

CTS SWH-2109FX user guide

TRENDnet TPE-T160 Specifications

TRENDnet

TRENDnet TPE-T160 Specifications

Allied Telesis XS910/8 manual

Allied Telesis

Allied Telesis XS910/8 manual

Tenda TEG1210P user guide

Tenda

Tenda TEG1210P user guide

Monoprice 33416 user manual

Monoprice

Monoprice 33416 user manual

Niko 10-825 manual

Niko

Niko 10-825 manual

H3C S5150-EI Series Configuration guide

H3C

H3C S5150-EI Series Configuration guide

Digital Extender DS-41R user manual

Digital Extender

Digital Extender DS-41R user manual

LEGRAND 672 34 quick start guide

LEGRAND

LEGRAND 672 34 quick start guide

3Com PathBuilder S200 Series user manual

3Com

3Com PathBuilder S200 Series user manual

Disaster Area Designs DPC.micro user manual

Disaster Area Designs

Disaster Area Designs DPC.micro user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.