Introduction
IGS-401F/402F(S) models are non-managed Gigabit Ethernet
switches that provide stable and reliable Ethernet transmission.
Housed in rugged DIN rail or wall mountable enclosures, these
switches are designed for harsh environments, such as industrial
networking and intelligent transportation systems (ITS) and are
also suitable for many military and utility market applications
where environmental conditions exceed commercial product
specifications. Standard operating temperature range models
(-10°C to 60°C) and wide operating temperature range models
(-40°C to 75°C) fulfill the special needs of industrial automation
applications.
Features
•Redundant dual DC inputs 12/24/48VDC
•IP30 rugged metal housing
•Wide temperature range -40°C~75°C (-E model)
•Support for Ethernet jumbo frames
•DIP switch enable/disable broadcast storm filter
•UL60950-1, CE, FCC, EN50121-4 Rail traffic
•Industrial EN61000-6-2 EMS, EN61000-6-4 EMI
Specifications
Ethernet Interface
•Connector: RJ-45 (shielded)
•4 ports
•Auto MDI/MDI-X
•Speed: 10/100/1000Base-T (Auto)
•Duplex: Full/Half (Auto-negotiation per IEEE802.3u)
•Supports IEEE802.3x Flow Control
•Store & Forward Switch
•Switching Fabric: 10Gbps non-blocking (IGS-401F); 12Gbps
non-blocking (IGS-402F & IGS-402S)
•Packet buffer: 1Mb
•Standards: IEEE802.3, 802.3u, 802.3x, 802.3ab, 802.3
•8K MAC table
•MTU: 64~10240 bytes
•Broadcast Storm protection (enable/disable by DIP)
Quick Installation Guide
IGS-401F, IGS-402F, IGS-402S
IGS-401F-E, IGS-402F-E, IGS-402S-E
Industrial Grade Gigabit Ethernet Switches
Specifications (cont.)
Optical Ethernet Interface
•1000Base-X, 1-port (IGS-401F), 2 ports (IGS-402F & IGS-402S)
•Fixed SC connectors (IGS-401F & IGS-402F)
•Pluggable SFP x 2 (IGS-402S)
•Multimode (2km) 50/125um, 62.5/125um
•Single mode (30km or 50km) 9/125um
•Wavelength: 1310nm (S/M or M/M)
Power
•Absolute range: 9.6VDC~60VDC
•Reverse polarity protection: Yes
•Dual power inputs: Yes
•Connector: removable terminal block
•Consumption: Max. 7.79W (IGS-401F); Max. 7.83W (IGS-402F
& IGS-402S)
Mechanical
•Water & Dust Proof: IP30 Protection
•Dimensions: 106 x 62.5 x 135mm (D x W x H)
•Mounting: DIN-Rail, Wall Mount (kits included)
•Weight: 670 g (IGS-401F); 680 g (IGS-402F & IGS-402S)
Environmental
•Operating Temperature: -10°C~60°C, -40°C~75°C (wide temp.
for -E model)
•Storage Temperature: -40°C~85°C
•Humidity: 5%~95% (non-condensing)
Certifications
•EMI: FCC Part 15 sub B class A, EN55022 Class A, EN61000-6-4
•EMS (Electromagnetic Susceptibility):
EN61000-6-2 Immunity for Industrial Environment
EN61000-4-2 (ESD) Level 3,Criteria B
EN61000-4-3 (RS) Level 3,Criteria A
EN61000-4-4 (Burst) Level 3,Criteria A
EN61000-4-5 (Surge) Level 3,Criteria B
EN61000-4-6 (CS) Level 3,Criteria A
EN61000-4-8 (Magnetic Field) Level 3,Criteria A
•Safety: UL60950-1
•Railway Traffic: EN50121-4
•Shock: EN60068-2-27
•Freefall: EN60068-2-32
•Vibration: EN60068-2-6
•MTBF: 407,596 hours (IGS-401F); 391,633 hours (IGS-402F);
438,031 hours (IGS-402S)
[email protected]
V1.3
To download this QIG or a more complete user manual, please visit
http://www.ctcu.com/Industrial/
w w w . c t c u . c o m
[email protected]
Connectors
IGS-401F IGS-402F IGS-402S
All models have four electrical LAN ports (labeled 1, 2, 3, 4) that
utili e shielded RJ-45 connectors. These ports support
10/100/1000M Auto Negotiation and Auto MDI/MDI-X Ethernet.
IGS-402F gigabit optical ports (Fiber 1 / Fiber 2) use fixed
transceivers with SC or ST optical connections for multimode or
single mode fiber depending on model. (IGS-401F model has only
one fiber port.)
IGS-402S model provides SFP cages and supports dual rate,
125Mbps or 1.25Gbps SFP modules, inserted into Fiber 1 and
Fiber 2 ports. Dual rate support allows use of specific SFP modules
for fiber connection to other gigabit Ethernet (1000Base-X)
equipment or to legacy Fast Ethernet fiber (100Base-FX).
Power, Alarm and DIP switch
A removable terminal block provides both power and alarm
connections. Power can be provided through the dual inputs from
separate sources. One electrical relay can be wired into an alarm
circuit. The relay is connected as Normally Closed (will open upon
alarm condition).
IGS-401F/402F uses a 2-pole DIP switch for configuration, while
the IGS-402S uses a 4-pole DIP switch for configuration. Each pole
of the switch has the following functions:
1. Alarm Enable: When 'ON' this switch will disable alarm relay
and fault LED if there is a power failure in one supply. If only
connecting to a single power source, place this switch 'ON' to
disable alarm.
2. BSP Enable: When 'ON' this switch will disable the broadcast
storm protection feature which is enabled by default.
3. Fiber 2: This dual rate fiber port (IGS-402S ONLY) supports
optical Ethernet rate of 100M or 1G, depending on the setting
and the inserted SFP module. When set to 'ON', the port supports
Fast Ethernet rate and should use an SFP rated for 125~155Mbps.
When set 'OFF', the port is configured for gigabit Ethernet and
requires a 1.25Gbps SFP module.
4. Fiber 1: The same settings as for Fiber 2 port.
LED Indicators
IGS-401F and IGS-402F(S) have LEDs on the front face that
report the condition of power, fault, Fiber link, LAN link and speed.
LED Color
Definition
PWR1 Green
L
it if power is connec
ted and active at
the PWR1/PWR2 input terminal
connection.
PWR2
Fault Amber
Lit
if one of the power inputs has fault
condition and as long as DIP switch #1 is
OFF.
Fiber Green
L
it when the fiber port has an optical link
and will flash when there is Ethernet
traffic
. (IGS
-
401F)
Fiber 1 Green
L
it when the fiber 1 port has an optical
link and will flash when there is Ethernet
traffic
. (IGS
-
402
F & IGS
-
402S
)
Fiber 2 Green
Lit
when the fiber 2 port has an optical
link and will flash when there is Ethernet
traffic.
(IGS
-
402
F & IGS
-
402S
)
100/1000
Off
R
emain off if the connected speed is
10M
.
Green
L
it when the LAN connected speed is
100M.
Amber
L
it when the LAN connected speed is
1000M.
LINK/ACT
Green
L
it
when the LAN port has a link and will
flash when
there is Ethernet traffic.
Installation
IGS-401F/402F(S) comes with both wall mount and DIN rail
hardware brackets. When installing the DIN rail bracket, be sure
to correctly align the orientation pin.
DIN Rail Wall Mount
IGS-401F/402F(S) with DIN Rail bracket has a steel spring in the
upper rail of the bracket. This spring is compressed for mounting
and un-mounting by applying downward force.
mounting un-mounting
w w w . c t c u . c o m
[email protected]
PWR
1
PWR
2
Fault
Fiber 1
Fiber 2
LINK/
ACT
100/
1000
LINK/
ACT
100/
1000

This manual suits for next models

5

Other CTC Union Switch manuals

CTC Union GSW-3208M User manual

CTC Union

CTC Union GSW-3208M User manual

CTC Union IGS?401F?4PH24 User manual

CTC Union

CTC Union IGS?401F?4PH24 User manual

CTC Union TSB4000 Series User manual

CTC Union

CTC Union TSB4000 Series User manual

CTC Union FSW-2104W User manual

CTC Union

CTC Union FSW-2104W User manual

CTC Union ITP-800A User manual

CTC Union

CTC Union ITP-800A User manual

CTC Union IFS?500 User manual

CTC Union

CTC Union IFS?500 User manual

CTC Union JB330 Series User manual

CTC Union

CTC Union JB330 Series User manual

CTC Union JB210 Series User manual

CTC Union

CTC Union JB210 Series User manual

CTC Union IGS-404SM User manual

CTC Union

CTC Union IGS-404SM User manual

CTC Union IGS-1608SM-SE User manual

CTC Union

CTC Union IGS-1608SM-SE User manual

CTC Union JB120 Series User manual

CTC Union

CTC Union JB120 Series User manual

CTC Union SB142 User manual

CTC Union

CTC Union SB142 User manual

CTC Union ITP-500 User manual

CTC Union

CTC Union ITP-500 User manual

CTC Union IGS?401F?4PH24 User manual

CTC Union

CTC Union IGS?401F?4PH24 User manual

CTC Union GSW-1005MS User manual

CTC Union

CTC Union GSW-1005MS User manual

CTC Union IFS-803GSM-8PH24 User manual

CTC Union

CTC Union IFS-803GSM-8PH24 User manual

CTC Union SB282 Series User manual

CTC Union

CTC Union SB282 Series User manual

CTC Union TSB1000 Series User manual

CTC Union

CTC Union TSB1000 Series User manual

CTC Union ITP-G800SM-8PH24 User manual

CTC Union

CTC Union ITP-G800SM-8PH24 User manual

CTC Union GSW-3208M2 User manual

CTC Union

CTC Union GSW-3208M2 User manual

CTC Union PHB-200 User manual

CTC Union

CTC Union PHB-200 User manual

CTC Union IFS+402GSM-4PHE24 User manual

CTC Union

CTC Union IFS+402GSM-4PHE24 User manual

CTC Union IFS?402F User manual

CTC Union

CTC Union IFS?402F User manual

CTC Union SB152 Series User manual

CTC Union

CTC Union SB152 Series User manual

Popular Switch manuals by other brands

Omron A22 manual

Omron

Omron A22 manual

Ormazabal velatia cgm.3 system General instructions

Ormazabal

Ormazabal velatia cgm.3 system General instructions

TP-Link JetStream T2600G-28TS user guide

TP-Link

TP-Link JetStream T2600G-28TS user guide

SMART VE220 Textless Install Instructions

SMART

SMART VE220 Textless Install Instructions

ERA 330503 Replacement procedure

ERA

ERA 330503 Replacement procedure

Kramer VS-33V user manual

Kramer

Kramer VS-33V user manual

Siemens SCALANCE X-200RNA operating instructions

Siemens

Siemens SCALANCE X-200RNA operating instructions

Tronic KH 1596 operating manual

Tronic

Tronic KH 1596 operating manual

Siqura XSNet C6108SW quick start guide

Siqura

Siqura XSNet C6108SW quick start guide

H3C S5120V3-EI Series troubleshooting guide

H3C

H3C S5120V3-EI Series troubleshooting guide

Amit RB-SW006/AM1 Operation manual

Amit

Amit RB-SW006/AM1 Operation manual

National Instruments SCXI Getting started guide

National Instruments

National Instruments SCXI Getting started guide

AXESS ELECTRONICS CFX4 quick guide

AXESS ELECTRONICS

AXESS ELECTRONICS CFX4 quick guide

Pickering 40-190B user manual

Pickering

Pickering 40-190B user manual

Bartec Ex d 07-4 Series operating instructions

Bartec

Bartec Ex d 07-4 Series operating instructions

AVT AVT1460 manual

AVT

AVT AVT1460 manual

IBM 8270 600 Brochure & specs

IBM

IBM 8270 600 Brochure & specs

Pepperl+Fuchs HiC284 Series manual

Pepperl+Fuchs

Pepperl+Fuchs HiC284 Series manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.