CTEK MXS 7.0 User manual

EN
EN • 3
ABSORPTION, READY TO USE
ANALYSE
RECOND
RECOND
MODE
12V/7A
MXS 7.0
SUPPLY
SUPPLY
NORMAL
AGM
CONGRATULATIONS
to the purchase of your new professional switch mode battery charger.
This charger is included in a series of professional chargers from CTEK SWEDEN AB and
represents the latest technology in battery charging.
CTEK COMFORT CONNECT – eyelet M8
CTEK COMFORT CONNECT
MAINS CABLE
CTEK COMFORT CONNECT – clamp
CHARGE CABLE
SUPPLY PLUG*
*Supply plugs may differ to suit your wall socket.
NORMAL
BATTERY
PROGRAM
ERROR LAMP
AGM
BATTERY
PROGRAM
RECOND
PROGRAM
SUPPLY
PROGRAM
POWER
LAMP
CHARGING
1. Connect the charger to the battery.
2. Connect the charger to the wall socket. The power lamp will indicate that the mains
cable is connected to the wall socket. The error lamp will indicate if the battery clamps
are incorrectly connected. The reverse polarity protection will ensure that the battery
or charger will not be damaged.
3. Press the MODE-button to select charging program.
4. Follow the indication lamps through the charging process.
The battery is ready to start the engine when is lit.
The battery is fully charged when is lit.
5. Stop charging at any time by disconnecting the mains cable from the wall socket.
MODE-
BUTTON
MANUAL
DESULPHATION
SOFT START BULK FLOAT, FULLY CHARGED
PULSE, MAINTENANCE CHARGING
20015462E MXS 7.0, Manual EU, Print file 002.indd 3 2011-10-11 07:58:00

4 • EN
BATTERY SIZE (Ah) TIME TO 80% CHARGED
20Ah 2h
50Ah 6h
100Ah 12h
150Ah 17h
READY TO USE
The table shows the estimated time for empty battery to 80% charge
CHARGING PROGRAMS
Settings are made by pressing the MODE-button. After about two seconds the charger
activates the selected program. The selected program will be restarted next time the
charger is connected.
The table explains the different Charging Programs:
Program Battery
Size (Ah) Explanation Temp range
NORMAL 14–225Ah Normal battery program
14.4V/7A. Use for WET batteries,
Ca/Ca, MF and for most GEL batteries
+5°C–+50°C
(41ºF–122ºF)
AGM
14–225Ah
AGM battery program 14.7 V/7A
Use for AGM batteries. -20°C–+5°C
(-4ºF–41ºF)
RECOND 14–225Ah
Recond program 15.8V/1.5A
Use to return energy to the empty
WET and Ca/Ca batteries. Recond
your battery once per year and after
deep dischare to maximise lifetime and
capacity. The Recond program adds the
Recond step to the normal battery
program. Frequent use of the Recond
program may cause water loss in the
batteries and reduce service life of
electronics. Contact your vehicle and
battery supplier for advice.
-20°C–+50°C
(-4ºF–122ºF)
14–225Ah
Supply program 13.6V/7A
Use as 12V power supply or use for
float maintenance charging when 100%
capacity of the battery is required.
Supply program activates Float step
without time or voltage limitation.
-20°C–+50°C
(-4ºF–122ºF)
ERROR LAMP
If the error lamp is lit, check the following:
1. Is the chargers positive lead connected to the
batterys positive pole?
2. Is the charger connected to a 12V battery?
3. The clamps are short circuited?
4. Has charging been interrupted in or ?
Restart the charger by pressing the MODE-button. If charging is
still being interrupted, the battery...
...is seriosly sulphated and may need to be replaced.
...can not accept charge and may need to be replaced.
...can not keep charge and may need to be replaced.
WARNING!
The spark protection on the battery charger
is disabled during SUPPLY program.
20015462E MXS 7.0, Manual EU, Print file 002.indd 4 2011-10-11 07:58:02

EN
EN • 5
STEP 1 DESULPHATION
Detects sulphated batteries. Pulsing current and voltage, removes sulphate from the lead
plates of the battery restoring the battery capacity.
STEP 2 SOFT START
Tests if the battery can accept charge. This step prevents that charging proceeds with a
defect battery.
STEP 3 BULK
Charging with maximum current until approximately 80% battery capacity.
STEP 4 ABSORPTION
Charging with declining current to maximize up to 100% battery capacity.
STEP 5 ANALYSE
Tests if the battery can hold charge. Batteries that can not hold charge may need to be replaced.
STEP 6 RECOND
Choose the Recond program to add the Recond step to the charging process. During the Recond step
voltage increases to create controlled gasing in the battery. Gasing mixes the battery acid and gives
back energy to the battery.
STEP 7 FLOAT
Maintaining the battery voltage at maximum level by providing a constant voltage charge.
STEP 8 PULSE
Maintaining the battery at 95–100% capacity. The charger monitors the battery voltage and gives a
pulse when necessary to keep the battery fully charged.
1
VOLTAGE (V)CURRENT (A)
ANALYSE RECOND PULSE
DESULPHATION SOFT START BULK ABSORPTION
14.4V
Increasing voltage
to 14.7V @ 25°C
7A
7A until 12.6V Increasing voltage
to 14.4V @ 25°C
7A
17
Limit: Max 20h Max 10h 3 minutes 30 min or 4h
depending on
battery voltage
10 days
Charge cycle restarts
if voltage drops*
Charge cycle restarts
if voltage drops
Max 8h
14.7V
14.4V 7A until 12.6V
7A until 12.6V
Increasing voltage
to 14.4V @ 25°C
7A
14.4V @ 25°C
Declining current
14.7V @ 25°C
Declining current
14.4V @ 25°C
Declining current
Checks if voltage
drops to 12V
Checks if voltage
drops to 12V
Checks if voltage
drops to 12V
Max 13.6V
7A
13.6V
7A
13.6V
7A
13.6V
7A
12.9V‒14.4V
7‒2A
12.9V‒14.7V
7‒2A
12.9V‒14.4V
7‒2A
Max 8h
2 3 4 5
FLOAT
6 8
RECOND
SUPPLY
AGM
NORMAL
Max 15.8V
1.5A
CHARGING PROGRAM
*Supply program is not time or voltage limited.
20015462E MXS 7.0, Manual EU, Print file 002.indd 5 2011-10-11 07:58:03

6 • EN
RECOND
RECOND
MODE
12V/7A
MXS 7.0
SUPPLY
SUPPLY
NORMAL
AGM
TECHNICAL SPECIFICATIONS
Charger model MXS 7.0
Model number 1053
Rated Voltage AC 220–240VAC, 50–60Hz
Charging voltage NORMAL 14.4V, AGM 14.7V, RECOND 15.8V, SUPPLY 13.6V
Start voltage 2.0V
Charging current 7.2A max
Current, mains 1.2A rms (at full charging current)
Back current drain* <1Ah/month
Ripple** <4%
Ambient
temperature -20°C to +50°C, output power is reduced
automatically at high temperatures
Charger type 8-step, fully automatic charging cycle
Battery types All types of 12V lead-acid batteries
(WET, MF, Ca/Ca, AGM and GEL)
Battery capacity 14―150Ah up to 225Ah for maintenance
Dimensions 191 x 89 x 48mm (L x W x H)
Insulation class IP65
Weight 0.8kg
*) Back current drain is the current that drains the battery if the charger is not connected
to the mains. CTEK chargers has a very low back current.
**) The quality of the charging voltage and charging current is very important. A high
current ripple heats up the battery which has an aging effect on the positive electrode.
High voltage ripple could harm other equipment that is connected to the battery. CTEK
battery chargers produce very clean voltage and current with low ripple.
CONNECT AND DISCONNECT THE CHARGER TO A BATTERY
Comfort
Connect
Comfort
Connect
INFO
If the battery clamps are incor-
rectly connected, the reverse
polarity protection will ensure that
the battery and charger are not
damaged.
For batteries mounted inside a
vehicle
1. Connect the red clamp to the bat-
tery's positive pole.
2. Connect the black clamp to the
vehicle chassis remote from the fuel
pipe and the battery.
3. Connect the charger to the wall
socket
4. Disconnect the charger from the wall
socket before disconnecting the battery
5. Disconnect the black clamp before
the red clamp.
Some vehicles may have posi-
tively earthed batteries.
1. Connect the black clamp to the bat-
tery's negative pole.
2. Connect the red clamp to the vehicle
chassis remote from the fuel pipe and
the battery.
3. Connect the charger to the wall
socket
4. Disconnect the charger from the wall
socket before disconnecting the battery
5. Disconnect the red clamp before the
black clamp.
20015462E MXS 7.0, Manual EU, Print file 002.indd 6 2011-10-11 07:58:04

EN
EN • 7
SAFETY
• The charger is designed for charging 12V lead-acid batteries. Do not use the charger
for any other purpose.
• Check the charger cables prior to use. Ensure that no cracks have occurred in the
cables or in the bend protection. A charger with damaged cables must not be used.
A damage cable must be replaced by a CTEK representative.
• Never charge a damaged battery.
• Never charge a frozen battery.
• Never place the charger on top of the battery when charging.
• Always provide for proper ventilation during charging.
• Avoid covering the charger.
• A battery being charged could emit explosive gasses. Prevent sparks close to the
battery. When batteries are reaching the end of their lifecycle internal sparks may occur.
• All batteries fail sooner or later. A battery that fails during charging is normally
taken care of by the chargers advanced control, but some rare errors in the battery
could still exist. Don’t leave any battery during charging unattended for a longer period
of time.
• Ensure that the cabling does not jam or comes into contact with hot surfaces or sharp
edges.
• Battery acid is corrosive. Rinse immediately with water if acid comes into contact
with skin or eyes, seek immediate medical advice.
• Always check that the charger has switched to before leaving the charger
unattended and connected for long periods. If the charger has not switched to
within 45 hours, this is an indication of an error. Manually disconnect the charger.
• Batteries consume water during use and charging. For batteries where water can
be added, the water level should be checked regularly. If the water level is low add
distilled water.
• This appliance is not designed for use by young children or people who cannot read
or understand the manual unless they are under the supervision of a responsible person
to ensure that they can use the battery charger safely. Store and use the battery charger
out of the reach of children, and ensure that children cannot play with the charger.
• Connection to the mains supply must be in accordance with the national regulations
for electrical installations.
LIMITED WARRANTY
CTEK SWEDEN AB, issues this limited warranty to the original purchaser of this product.
This limited warranty is not transferable. The warranty applies to manufacturing faults
and material defects for 5 years from the date of purchase. The customer must return the
product together with the receipt of purchase to the point of purchase. This warranty is
void if the battery charger has been opened, handled carelessly or repaired by anyone
other than CTEK SWEDEN AB or its authorised representatives. One of the screw
holes in the bottom of the charger is sealed. Removing or damaging the seal will void
the warranty. CTEK SWEDEN AB makes no warranty other than this limited warranty
and is not liable for any costs other than those mentioned above, i.e. no consequential
damages. Moreover, CTEK SWEDEN AB is not obligated to any warranty other than this
warranty.
SUPPORT
CTEK offers a professional customer support: www.ctek.com.
For latest revised user manual see www.ctek.com. By e-mail: info@ctek.se,
by telephone: +46(0) 225 351 80, by fax +46(0) 225 351 95.
By mail: CTEK SWEDEN AB, Rostugnsvägen 3, SE-776 70 VIKMANSHYTTAN,
SWEDEN.
VIKMANSHYTTAN, SWEDEN 2011-09-01
Bengt Hagander, President
CTEK SWEDEN AB
20015462E MXS 7.0, Manual EU, Print file 002.indd 7 2011-10-11 07:58:05
Other manuals for MXS 7.0
3
This manual suits for next models
1
Table of contents
Other CTEK Batteries Charger manuals

CTEK
CTEK US 800 User manual

CTEK
CTEK MULTI US 3300 User manual

CTEK
CTEK D250SE User manual

CTEK
CTEK MULTI XS 3600 Assembly instructions

CTEK
CTEK 1055 User manual

CTEK
CTEK MXS 25 User manual

CTEK
CTEK CS ONE User manual

CTEK
CTEK US RACING User manual

CTEK
CTEK XS 800 User manual

CTEK
CTEK MULTI US 7000 User manual

CTEK
CTEK SMARTPASS 120S User manual

CTEK
CTEK MXT 14000 AE User manual

CTEK
CTEK PRO120 User manual

CTEK
CTEK MULTI US 25000 User manual

CTEK
CTEK MXS 3.6 User manual

CTEK
CTEK D250S Dual User manual

CTEK
CTEK 1082 User manual

CTEK
CTEK XS 0.8 User manual

CTEK
CTEK MXS 7.0 User manual

CTEK
CTEK MULTI US 25000/MXS 25EC NA User manual