800-641-4282
www.dmp.com 2500 North Partnership Boulevard
LT-1106 1.05 © 2015 Digital Monitoring Products, Inc.
15055
Battery Power
Observepolaritywheninstallingthebatteries.Useonly3.0VLithiumbatteries,DMPModelCR123,ortheequivalent
batteryfromalocalretailoutlet.ForULinstallations,onlyuse#123batteriesmanufacturedbyEnergizer.
1.Removethelockingscrewfromthesideofthesirenhousing.
2.Liftthecoverfromthebottomtoremove.
3.Ifreplacingthebatteries,removetheoldbatteriesanddisposeofproperly.Alwaysreplacebothbatteriesatthe
same time.
Caution:Properlydisposeofunusedbatteries.Donotrecharge,disassemble,heatabove212°F(100°C),or
incinerate.Thereisariskofre,explosion,andburnswithimproperdisposal.
4.PlacethetwoCR123batteriesintheholdersandpressintoplace.SeeFigure2forbatterylocation.
5.Setthecoverbackintoplaceandreplacethelockingscrew.
Battery Life Expectancy
Batterylifeexpectancyforthe1135is3yearswherethesirenisoperatedforveminutesonceamonth.Refertothe
panelprogrammingguideasneeded.DMPwirelessequipmentusestwo-waycommunicationtoextendbatterylife.
The following situation can extend battery life expectancy:
•Infrequentsirenon/offoperations
•Extendtransmittersupervisiontimeinpanelprogramming
The following situations can reduce battery life expectancy:
•Multiplesirenon/offoperations
•Wheninstalledinextremehotorcoldenvironments
FCC Information
ThisdevicecomplieswithPart15oftheFCCRules.Operationissubjecttothefollowingtwoconditions:
(1)Thisdevicemaynotcauseharmfulinterference,and
(2)thisdevicemustacceptanyinterferencereceived,includinginterferencethatmaycauseundesiredoperation.
Theantennausedforthistransmittermustbeinstalledtoprovideaseparationdistanceofatleast20cm(7.874in.)fromall
persons.Itmustnotbelocatedoroperatedinconjunctionwithanyotherantennaortransmitter.
Changesormodicationsmadebytheuserandnotexpresslyapprovedbythepartyresponsibleforcompliancecouldvoidthe
user’s authority to operate the equipment.
Note:ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBdigitaldevice,pursuanttopart15ofthe
FCCRules.Theselimitsaredesignedtoprovidereasonableprotectionagainstharmfulinterferenceinaresidentialinstallation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions,maycauseharmfulinterferencetoradiocommunications.However,thereisnoguaranteethatinterferencewillnot
occurinaparticularinstallation.Ifthisequipmentdoescauseharmfulinterferencetoradioortelevisionreception,whichcanbe
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
-Reorientorrelocatethereceivingantenna.
-Increasetheseparationbetweentheequipmentandreceiver.
-Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiverisconnected.
-Consultthedealeroranexperiencedradio/TVtechnicianforhelp.
Listed Compliance Specications
Commercial Burglary
The wall tamper must be enabled for commercial burglary applications.
Installonlyonnon-conductivesurfaces.
Household Fire
SupervisionTimemustbe3minutesforreapplications.
Compatibility
1100DWirelessReceiver
1100DHWirelessHighPowerReceiver
1100DIWirelessIn-lineReceiver
1100XWirelessReceiver
1100XHWirelessHighPowerReceiver
XTL,XTLN,andXTLN-WiFiPanels
XT30/XT50Panels(usingsoftwareversion106orhigher)
XR100/XR500Panels(usingsoftwareversion207orhigher)
XR150/XR350/XR550Panels
Patents
U.S.PatentNo.7,239,236
Certications
FCCPart15RegistrationIDCCKPC0123
IndustryCanadaRegistrationID5251A-PC0123
ANSI/UL1023HouseholdBurglarAlarmSystemUnits
ANSI/UL1610CentralStationBurglarAlarmUnits
ANSI/UL985HouseholdFireWarningSystem
Specications
Battery
Life Expectancy 3 Years
Type 3.0VLithiumCR123A
See Battery Life Expectancy for full details.
FrequencyRange 903-927MHz
Decibel Level 100 dB at 3 ft.
Dimensions 4.5”Lx4.5”Wx1.25”H
Color White
HousingMaterial FlameretardantABS
Accessories
CR123 3.0VLithiumBattery