Dorma 8900 PT User manual

PAGE
INS NO. Rev.
08279731 09/09
1 of 3
C
1
2
3
4
(1) (WOOD AND METAL)
QTY
(2)
(2)
Insert slide shoe, rubber stop and end blocks
into track and attach track to frame.
RUBBER STOP
SLIDE SHOE
END BLOCK
NOTE: OUTER TWO SCREWS PASS THROUGH END
(METAL)
(WOOD)
QTY
QTY
L HINGE
C
BLOCKS.
END BLOCK
Assemble track and attach to frame.
(PT UNITS ONLY)
(PTH UNITS ONLY)
QTY
(1) ARM TO SLIDE SHOE
stop, hold open mechanism, and end blocks into
and tighten securely. Insert slide shoe, rubber
Attach arm to slide shoe using screw supplied
track and attach track to frame.
IMPORTANT :
END BLOCK
L HINGE
C
RUBBER STOP
END BLOCK
SLIDE SHOE
L HINGE
C
NOTE: HOLD OPEN MECHANISM AND SLIDE SHOE MUST
BE INSTALLED WITH ARROWS POINTING AWAY
FROM THE DOOR HINGES. (ARROWS ARE
STAMPED ON SLIDE SHOE & HOLD OPEN
MECHANISM)
HOLD OPEN MECHANISM
M6 HEX KEY
according to appropriate template.
Determine hand of door. Prepare door and frame
(REFERENCE UNIT CARTON FOR ACCESSORIES AND
OPTIONS SUPPLIED)
LISTINGS.
IDENTIFIED IN THE INDIVIDUAL DOOR MANUFACTURER'S
DOORS, UNLESS AN ALTERNATIVE METHOD IS
WOOD OR PLASTIC FACED COMPOSITE TYPE FIRE
OF COMPONENTS TO UNREINFORCED DOORS AND TO
CAUTION: SEX NUTS ARE REQUIRED FOR ATTACHMENT
REVERSE BEVEL
RIGHT HAND DOOR
LEFT HAND DOOR
REVERSE BEVEL
RIGHT HAND LEFT HAND
WOOD DOORS
SN1 (Sex Nuts)
METAL DOORS or
QTY
(4)
(4)
QTY
as shown. Arrow on plate to point toward arm
BP89 Plate applications only. Attach plate to door
attachment.
(RH DOOR)
(LH DOOR)
adjustment facing hinges.
Attach closer to door or plate with spring
(LEFT HAND DOOR)
HINGESC
L
PLATE
METAL DOORS or SN1 (Sex Nuts)
WOOD DOORS
(RIGHT HAND DOOR)
QTY
(4)
(4)
QTY
QTY
(4)
HINGES
L
AND ACCESSORY PLATE BP89
8900 PT, PTH
PUSH SIDE TRACK MOUNT (TRACK ON FRAME)
INSPK NO. 08279730 Rev.09/09
www.dorma-usa.com 1-800-523-8483
Install main arm
Place wrench on bottom
pinion.
Rotate pinion 45° TOWARD HINGE edge of door.
45°
pinion screw.
With main arm parallel to door, place main
arm onto top pinion. Fasten securely with
6
5
Adjust according to chart.
ADJUSTER
FULL TURNS
OF SPRING
0
+8
+16
FULL TURNS
OF SPRING
ADJUSTING NUT
ADJUST SPRING TENSION ACCORDING TO THE FOLLOWING CHART.
8916
8956
CLOSER
ULC LABELED UNITS ONLY
TYPE
200
200 6
5
60
SIZE
SPRING
DOOR
WEIGHT
150
125
MAX.
4
NON-BARRIER-FREE OPENINGS -
TYPE
8916
8956
CLOSER
INTERIOR
2'-6"
3'-6"
3'-0"
4'-0"
+8
0
+16
0
DOOR WIDTH
5
6
6
4
SPRING
SIZE
Take an opening force reading from
the pull on the door. If required, adjust the spring tension
to meet the barrier-free requirement. Maximum number of
adjusted to meet barrier-free forces may not have sufficient
power to reliably close and latch the door.
turns counter clockwise=8. Maximum number of turns
clockwise =14. Depending on opening conditions, a door
BARRIER-FREE OPENINGS -
8916 ONLY
ADJUSTER
Adjust spring tension, if required, using a 1/4" wrench.
8956 supplied with size 6 setting.
8916 supplied with size 3 spring setting.
SPRING TENSION
CRITICAL
NOTE:
+
-
3'-6" +6 6+
+6
6+
250
LEFT HAND IS A MIRROR IMAGE.
INSTALLATION SHOWN.
NOTE: RIGHT HAND DOOR
PINION SCREW
L HINGE
C
PINION
6mm HEX KEY
ROTATE
PINION
45°
(1)
QTY
08279731 2 of 3 09/09
INS NO. PAGE Rev.
M2.5 HEX KEY
mechanism in desired
Place the hold open
position and tighten screw.
SNAP VALVE ADJUSTMENT
WRENCH INSIDE COVER
9
To adjust hold open
force, turn clockwise to
increase force, and
counter clockwise to
To enable hold open,
push the white slide into
the hold open mechanism.
To disable hold open,
A
B
C
(HOLD OPEN UNITS ONLY)
Set hold open.
weaken force.
M2.5 HEX KEY
OFFON
pull the white slide away
from hold open mechanism.
BACKCHECK OR DELAYED ACTION
NOTE: DELAYED ACTION IS AN OPTIONAL FEATURE.
DECREASE
CAUTION: DO NOT REMOVE VALVES.
DELAYED ACTION
BACKCHECK RANGE
SWEEP (SPEED)
INCREASE
(SPEED)
LATCH
RANGE
(TIME)
ACTION
DELAYED
SWEEP & LATCH
POSITIONING VALVE
BACKCHECK (INTENSITY)
RANGE
LATCH
SWEEP
RANGE
DECREASE
INCREASE
8
NOTE: LEFT HAND INSTALLATION SHOWN. RIGHT
(2)
TAB
QTY
HAND IS A MIRROR IMAGE.
screws provided.
Place cover over closer and fasten securely with
Place tab in cover slot opposite main arm.
08279731 3 of 3 09/09
INS NO. PAGE Rev.
7
control when extra time is required to pass through
Optional delayed action offers additional closing speed
the door. All valve adjustments are made with a 3/32"
hex key.
door and objects behind the door. Closing the backcheck
positioning valve fully clockwise advances the backcheck
range approximately 15°. Backcheck position valve is shipped
in the "on" position (to turn off, rotate valve counterclockwise
only 1/2 turn).
should take a minimum of 1.5 seconds. Backcheck
under control during the opening cycle protecting the
intensity should be adjusted to ensure that the door is
Closing time from 15° to fully closed (latch range)
generally adjusted to take a minimum of 3 seconds.
Closing time from 90° to 15° (sweep range) is
Adjust sweep, latch and backcheck valves.

This manual suits for next models

1

Other Dorma Door Opening System manuals

Dorma 9800FL Series User manual

Dorma

Dorma 9800FL Series User manual

Dorma TS93 T User manual

Dorma

Dorma TS93 T User manual

Dorma AS 350 User manual

Dorma

Dorma AS 350 User manual

Dorma CS 80 MAGNEO Manual

Dorma

Dorma CS 80 MAGNEO Manual

Dorma 7300 SPA User manual

Dorma

Dorma 7300 SPA User manual

Dorma RTS Series User manual

Dorma

Dorma RTS Series User manual

Dorma ED 100 User manual

Dorma

Dorma ED 100 User manual

Dorma 7400 TDE User manual

Dorma

Dorma 7400 TDE User manual

Dorma MUTO PREMIUM XL 80/150 SYNCHRO User manual

Dorma

Dorma MUTO PREMIUM XL 80/150 SYNCHRO User manual

Dorma 8616 T User manual

Dorma

Dorma 8616 T User manual

Dorma ED 100 User manual

Dorma

Dorma ED 100 User manual

Dorma 9800 Series User manual

Dorma

Dorma 9800 Series User manual

Dorma G-SR BG User manual

Dorma

Dorma G-SR BG User manual

Dorma PORTEO Instruction manual

Dorma

Dorma PORTEO Instruction manual

Dorma ED 100 Installation and operation manual

Dorma

Dorma ED 100 Installation and operation manual

Dorma 8916 AF8MJ User manual

Dorma

Dorma 8916 AF8MJ User manual

Dorma STA Series User manual

Dorma

Dorma STA Series User manual

Dorma 7400 DS User manual

Dorma

Dorma 7400 DS User manual

Dorma CS 80 MAGNEO User manual

Dorma

Dorma CS 80 MAGNEO User manual

Dorma 8900 FH User manual

Dorma

Dorma 8900 FH User manual

Dorma TS 99 FLR-K Manual

Dorma

Dorma TS 99 FLR-K Manual

Dorma 900S Series User manual

Dorma

Dorma 900S Series User manual

Dorma 7300 PT User manual

Dorma

Dorma 7300 PT User manual

Dorma 7414 ARNP User manual

Dorma

Dorma 7414 ARNP User manual

Popular Door Opening System manuals by other brands

Mobeye Call-Key MCK100 installation manual

Mobeye

Mobeye Call-Key MCK100 installation manual

SALICE Lapis Assembly instructions

SALICE

SALICE Lapis Assembly instructions

Cal-Royal N-F77CVR Installation instruction

Cal-Royal

Cal-Royal N-F77CVR Installation instruction

Scrigno OPEN1000 Assembly manual

Scrigno

Scrigno OPEN1000 Assembly manual

BFT WIND RMB 130B 200 installation manual

BFT

BFT WIND RMB 130B 200 installation manual

Alecto ADI-250 user manual

Alecto

Alecto ADI-250 user manual

Besam Swingmaster MP Installation, adjustment and maintenance instructions

Besam

Besam Swingmaster MP Installation, adjustment and maintenance instructions

Assa Abloy SARGENT 1431 Series instructions

Assa Abloy

Assa Abloy SARGENT 1431 Series instructions

GAL MOVFR Quick setup

GAL

GAL MOVFR Quick setup

Häfele Finetta T 70 VF manual

Häfele

Häfele Finetta T 70 VF manual

AGS D-PL Instructions for fitting, operating and maintenance

AGS

AGS D-PL Instructions for fitting, operating and maintenance

Stanley MA900ñ Installation and owner's manual

Stanley

Stanley MA900ñ Installation and owner's manual

WITTUR Hydra Plus UD300 Instruction handbook

WITTUR

WITTUR Hydra Plus UD300 Instruction handbook

Alutech TR-3019-230E-ICU Assembly and operation manual

Alutech

Alutech TR-3019-230E-ICU Assembly and operation manual

Pamex KT-INP35 Installation instruction

Pamex

Pamex KT-INP35 Installation instruction

MPC ATD ACTUATOR 50 ATD-313186 Operating and OPERATING AND INSTALLATION Manual

MPC

MPC ATD ACTUATOR 50 ATD-313186 Operating and OPERATING AND INSTALLATION Manual

Chamberlain T user guide

Chamberlain

Chamberlain T user guide

Fireco Dorgard operating guide

Fireco

Fireco Dorgard operating guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.