8UL TRA VIO LET COUN TERF EIT DE TEC TOR DORS 145
It pro vi des se cu re authen ti ci ty ve ri fi-
ca tion of the fol lowing pro tec ti ve fe a-
tu res on bank no tes and docu ments:
• ab sen ce of gen eral pa per lu mi nes-
cen ce background;
• pres en ce of lu mi nes cen ce ar eas
(marks, fib ers, ima ge frag ments).
It pro vi des ve ri fi ca tion of the fol-
lowing fe a tu res:
• prin ting ty pes;
• prin ting methods;
• ima ge frag ments, ma de by op ti cal ly
va ri ab le inks;
• se cu ri ty ho lo grams;
• la tent ima ges;
• re ve a ling prin ting de fects and pos si-
ble era su res.
It pro vi des ve ri fi ca tion of the fol-
lowing pro tec ti ve fe a tu res:
• wa ter marks;
• se cu ri ty thre ads;
• mic ro per fo ra tion;
• matching ima ges of the fa ce and
re ver se si des of bank no te.
Control sca le on the matt bot tom glass
pro vi des ve ri fi ca tion of the bank no te
si ze, location of pro tec ti ve marks, al so
me a su re si ze of the lost frag ment (fit-
ness for use as cur ren cy).
Re mo te op ti cal mag ni fi er with builtin
whi te lighting DORS 10* pro vi des
de ta i led in ves ti ga tion of:
• prin ting ty pes and methods;
• graphi cal se cu ri ty fe a tu res (mic ro
text, mic ro ima ges, fi neli ne net-
ting, etc.);
• la tent ima ges;
• se cu ri ty ho lo grams;
• prin ting de fects;
• era su res.
Re mo te vi sua i liz er of mag net ic and
in fra red marks DORS 15** pro vi des
ve ri fi ca tion of spe cial pro tec ti ve
marks, texts and ima ges, ma de by fer-
ro mag net ic inks.
Re mo te vi sua i liz er of mag net ic and
in fra red marks DORS 15** pro vi des
ve ri fi ca tion of ima ges ma de by IRme-
ta me ric inks.
* De tec tor is not sup pli ed with DORS 10, which should be or de red se pa ra te ly.
** De tec tor is not sup pli ed with DORS 15, which should be or de red se pa ra te ly.
9
UL TRA VIO LET COUN TERF EIT DE TEC TOR DORS 145
The detector should be sto red in the
ma nu fac tu rer's pac ka ge in he a ted
sto rehous es un der the tem pe ra tu re
from plus 5°С to plus 40°С and re la ti ve
air hu mi di ty not ex ce e ding 80 % at
plus 25°С.
The detector may be trans por ted in
the ma nu fac tu rer's pac ka ge (for not
mo re than 30 da ys) by truck or ra ilway
trans port in con ta i ners or house cars
or by air trans port in the pres su red
com part ments un der the tem pe ra tu re
from minus 30°С to plus 50°С, re la ti ve
air hu mi di ty not ex ce e ding 98% at
plus 25°С and pres su re from 84 to
107 kPa (630 to 800 mm Hg).
After replacement, the tubes should be delivered
to the luminescent tube utilization agency
1. In case of the blue or white light is
turned off while the power indi-
cator is still functioning, probably
the of the
detector is actuated. The thermal
protection prevents failure of elec-
tronics. While it is actuated, power
supply of the tube is off.
To reset the thermal protection,
turn off the detector and discon-
nect it from the wall outlet for
more than 3 min. If the tube does
not light up when turning on
again, it should be replaced.
Replacement of the tube should be
performed by
.
2. In case of power indicator on the
plugged in detector does not work,
please check:
a) check the current of the sup-
ply voltage;
b) probably the power cord is
damaged or the safety fuse
does not work; in both cases,
please, apply to the service
center.
Flashes in lamps within 120 hours since lamp work start are not defects.