98 AUTOMATIC DETECTOR DORS 200 AUTOMATIC DETECTOR DORS 200
CONTENTS
Calibration settings were accidentally
erased during the operation.
You can still use the detector though the
higher rejection rate of the banknotes is
possible.
The message will disappear at the
beginning of scanning process or after
long pressing of «REPORT/CLEAR»
key.
To deactivate the message and
decrease the rejection rate of the
banknotes please contact your vendor.
Red indicator
flashes every 3s,
blue indicator is on.
Table «Error Messages»
Messages that appear during self-testing of the detector
Indicator
status
Message Error description
and possible reason
Troubleshooting
Denomination and
quantity display area
is empty
The banknote (or emission of the
banknote) is not supported by current
currency database version.
The banknote is too worn out or
damaged. The banknote is suspicious.
The banknote has wrong dimensions or
hasn't been aligned to the left when being
scanned. The time limit for verification is
exceeded (the banknote is stopped in the
input tray).
Please repeat the verification process of
this banknote. If the banknote can't be
detected again, it has to be verified by
other means.
Red and blue indicators
are on.
«ACC LO»
Denomination and
quantity of verified
banknotes (the banknote
is detected).
Or no information about
the denomination and
quantity on display
(suspicious banknote).
The banknote is jammed, the feeding
rollers got dirty or path components are
broken.
Open the top cover. Remove the foreign
objects from the path. Close the top
cover. If the banknote gets jammed in
the removable tray, switch the detector
off, remove the tray and remove the
jammed banknote. Install the tray on its
place. Switch the detector on.
Red indicator flashes,
blue indicator is on.
No changes The top cover is not closed tightly. The
scanner window is dirty. The light guide
surface is dirty.
Switch off the detector. Open the top
cover of the detector. Wipe the light
guide and the scanner with a dry lint-
free cloth and remove foreign objects
from the path. Close the cover tightly.
Switch the detector on. If the error
happens again please contact your
vendor.
Blue indicator
flashes
The battery is discharged. Connect power adapter.
Can't switch on when powered from the adapter. Check the mains power, AC adapter connection to the mains outlet, and AC
adapter connection to the detector. If these conditions are met but the detector
fails to switch on, please contact your vendor.
The scanning doesn't begin when the banknote is
in the input tray.
1. Align the banknote to the left side of input tray.
2. If the banknote has a folded or damaged corner, feed the banknote so that the
start sensor is covered with the banknote.
3. Detector failure happened while operation; take out the banknote and restart
the device
4. Low battery, connect power adapter.
If these conditions are met but the detector fails to scan, please contact your
vendor.
The display shows a message which is not
described in this manual.
Switch off and then switch on the detector. If the error remains, contact your
vendor.
Troubleshooting table
TroubleshootingProblem
Can't switch on when powered from battery (the
battery is discharged).
Connect the AC adapter to the detector, connect the AC adapter to the mains.
Banknotes to be verified.................................... According to the firmware version
Banknote feeding.............................................. Short side forward, aligned to the left
side of input tray;
Detection speed (with tray removed)................. >=100 notes/min;
Display (option)................................................. Seven-segment LEDs;
Power consumption.......................................... Adapter input 100… 240V, 50…60Hz,
0.25A; Detector DC input 12V 0.7A.
Battery capacity (option)................................... 2300 mAh;
Operation temperature...................................... +10°…+35°C;
Relative humidity @+25°C................................ 40%... 80%;
Atmospheric pressure....................................... 84…107 kPa (630…800 mmHg);
Size.................................................................. 115x112x60 mm;
Path width......................................................... 86mm;
Net weight:
— battery version.............................................. 0.42 kg;
— no battery version......................................... 0.37 kg;
Gross weight..................................................... 1.0 kg.
Design and specifications are subject to change sake for product improvement
without prior notice. A device shown in the pictures may differ from a serial product.
SPECIFICATIONS