Instruction for use
Group plug-in card GE 628 (-L) V2
for Smoke Vent Control Panel RZN 43xx-E (GE 628 V2)
and Ventilation Control Panel (GE 628-L V2)
Function
- drives up to max. 10A connectable per group plug-in card
- possibility of combining with further groups
- adjustable ventilation time limitation and
OPEN-running time limitation
GE 628 V2 GE 628-L V2
DIP-switch 1 on ON
DIP- 3 ON
DIP- 4 ON
DIP- 4 OFF
DIP- 5 ON
DIP- 5 OFF
DIP- 6 ON - no
DIP- 7 ON
DIP- 8 ON
DIP- 9 ON
DIP- 10 ON
Functions special:
DIP-switch 2 on ON Ventilation time limitation
switch on
switch on
switch on
switch on
switch on
switch on function -
switch on
switch on - no function -
switch on
switch on
NSHEVs
NSHEVs
/ NSHEVs
/ NSHEVs .
he drives/ NSHEVs i
the drives/ NSHEVs
The drives/ NSHEVs
The drives
the drives
T
- for control of smoke and heat vent drives/ - for control of ventilation drives
in conjunction with the line plug-in card LE 513
- smoke vent retriggering function
- group-fault display
- power failure-CLOSED function
O direct
n OPEN-dire s/
be retriggered again.
Press ventilating button 1x shortly > will be closing up to its final position
will be closing only so long as the ventilating button s pressed.
Press ventilating button 1x shortly > will run open up to its final position.
will run open only so long as the ventilating button is pressed.
The drives/ NSHEVs will run closed in case of alarm.
In case of power failure, the drives/ NSHEVs will run
closed.
The smoke vent is triggered for a duration of 30 minutes
in intervals of 2 minutes according to VdS 2581.
The group plug-in card can be triggered in OPEN-direction viaAz signals.
The group plug-in card can be triggered in CLOSED-direction via Zz signals.
in ventilation operation
Storage operation in CLOSED-direction
Key operation in CLOSED-direction
Storage operation in OPEN-direction
Key operation in OPEN-direction
Group CLOSED in case of alarm
- no function, if control panel has
no emergency power supply -
Alarm re-clocking
PEN-
(If for example a rain detector is
connected, the switch must be on ON, because otherwise no „running CLOSED“ will take place.)
OPEN-running time limitation
OPEN-retriggering
Power failure-CLOSED
Using a potentiometer, running time in ion can be limited. If the vent button is
actuated i ction, the drive open as long as the running time is set.
Only possible in conjunction with DIP-switches 4 = ON (storage operation in CLOSED-direction)!
Using a potentiometer, ventilation time can be set.
will automatically close again, after the adjusted time has expired.
Only possible in conjunction with DIP-switches 1 = ON (OPEN-running time limitation)!
If DIP-switch 1 is switched on ON, the OPEN-running time limitation can
Only possible in conjunction with DIP-switches 4 = ON.
factory
setting