Dräger P7-TD – Quick Reference Guide
Any use of the Dräger P7-TD requires the full understanding of and compliance with the
instruction manual 5695075 (P7-TD) for this device.
The instruction manual can be found on our website www.draeger-msi.de/en in the menu item
Services >Downloads>P7 >Operating Instructions.
You can find the measurement data management software PC200P, which you can download after a brief
registration using your device number and your address data, in the menu item Services >Downloads >P7>
Software.
Only charge the Dräger P7 using the corresponding charger.
Key functions
Switching on: Simultaneously press the keys “F” and “H” for 1 second.
Switching off: Press the “F” key for more than 3 seconds or select “Switch off” in the “Functions” area.
All other key functions are shown on the display directly using the keys!
Functions
The individual tests and measurements are accessed via the “Functions” menu.
Pressure measurements
1. High pressure up to 0.12 MPa (1.2 bar)
Use pressure hose with pneumatic quick coupling NW5
2. Medium pressure up to 150 hPa (mbar)
3. Micro pressure up to 100 Pascal
4. Medium pressure up to 150 hPa (mbar) with pump function
5. High pressure up to 0.35 MPa (3.5 bar) or 2.5 MPa (25 bar) (with external high pressure sensor)
Follow the instructions for the Dräger P7 for pipeline testing!
Manual tightness test with absolute pressure and temperature compensation
Test pressure, stabilization period and measurement period can be set during the manual tightness test.
1. Select measuring channel 0 - 150 hPa (mbar), 0 - 3,500 hPa (mbar) or 0 - 25,000 hPa (mbar)
2. Select test pressure: 10 - 150 hPa (mbar), 100 - 3,500 hPa (mbar) or 1,000 - 25,000 hPa (mbar)
If a tightness test was selected in the 0 - 150 hPa (mbar) measuring channel, the internal or an external
pump can be used, to build up the test pressure. Tests with the 3,500 hPa (mbar) or 25,000 hPa (mbar)
channels can only be conducted using an external pump.
3. Select stabilization period: 00:01 - 12:00 h
4. Select measurement period: 00:01 - 12:00 h
Dräger MSI GmbH Tel.: +49 (0) 2331 / 9584 - 0 5695076
Rohrstr. 32 Fax: +49 (0) 2331 / 9584 – 29 Edition 02 – January 2019 (Edition 01 – June 2017)
58093 Hagen Email: msi.info@draeger.com en
Gas pipelines:
1. Serviceability (TRGI G 600) without dismantling the gas meter
Gas leak rate < 1l/h = unrestricted serviceability
Gas leak rate 1 l/h < 5 l/h = reduced serviceability (repair within 4 weeks)
Gas leak rate > 5 l/h = no serviceability (shut down immediately)
The actual operating pressure must be set as the nominal operating pressure for operating
pressures > 30 hPa (mbar); otherwise the operating pressure must be set to 23 hPa (mbar).
Use “leak measurement with regulator in line” for pipelines with a pressure regulator. The test pressure
is released under operating pressure, to fully open the regulator. The quick test and the measurement
for expanded volume are not DVGW (German competence network for all questions related to gas
and water supply) tested and cannot be stored. Depending on the stability in the gas pipeline, a quick
test can be conducted in approx. 7 minutes.
2. Automatic tightness test (TRGI G 600) 150 hPa (mbar)
3. Tightness test with external pump (TRGI G 600) 150 hPa (mbar)
Our recommendation for pipeline volumes exceeding 100 l.
Adaptation time and test duration for tightness tests according to TRGI G 600
4. Stress test (TRGI G 600) 0.1 MPa (1 bar) (0.3 MPa (3 bar) for medium pressure systems)
always with external pump
Use pressure hose with pneumatic quick coupling NW5 or an external sensor.
Stabilization period 2 - 10 minutes
Measurement period 10 minutes
Medium pressure systems: Stabilization period: 180 minutes
Measurement period: 120 minutes
The test duration must be prolonged by 15 minutes per additional 100 l of pipeline volume for
medium pressure systems with pipeline volumes exceeding 2000 l.
Pressure Volume
A
daptation time
Test
duration
150 hPa
(
mbar
)
< 100 l 10 min 10 min
150 hPa
(
mbar
)
≥100 l
< 200 l 30 min 20 min
150 hPa
(
mbar
)
≥200 l 60 min 30 min
Dräger MSI GmbH Tel.: +49 (0) 2331 / 9584 - 0 5695076
Rohrstr. 32 Fax: +49 (0) 2331 / 9584 – 29 Edition 02 – January 2019 (Edition 01 – June 2017)
58093 Hagen Email: msi.info@draeger.com en
Water pipelines:
1. Automatic tightness test (DIN EN 806) 150 hPa (mbar)
Enter the volume of the water pipeline
Stabilization period 2 - 10 minutes
Measurement period 120 minutes for a volume up to 100 l
The measurement period is prolonged by 20 minutes for each additional 100 l of pipeline volume.
2. Tightness test (DIN EN 806) 150 hPa (mbar) with external pump
Enter the volume of the water pipeline
Stabilization period 2 - 10 minutes
Measurement period 120 minutes for a volume up to 100 l
The measurement period is prolonged by 20 minutes for each additional 100 l of pipeline volume.
3. Stress test up to DN50 max. of 0.3 MPa (3 bar) or up to DN100 0.1 MPa (1 bar) (DIN EN 806)
always with external pump
Use pressure hose with pneumatic quick coupling NW5 or an external sensor.
Stabilization period 2 - 10 minutes
Measurement period 10 minutes
4. Press connections (unpressed untight) with water 0.6 MPa (6 bar) (DIN EN 806)
with external high pressure sensor
Stabilization period 10 minutes
Measurement period 15 minutes
5. Tightness test with water 1.1 MPa (11 bar) (DIN EN 806)
with external high pressure sensor
Stabilization and measurement period depends on the material
After completion of the measurement, all measurements can be printed using an infrared printer or stored in
the Dräger P7.
Dräger MSI GmbH Tel.: +49 (0) 2331 / 9584 - 0 5695076
Rohrstr. 32 Fax: +49 (0) 2331 / 9584 – 29 Edition 02 – January 2019 (Edition 01 – June 2017)
58093 Hagen Email: msi.info@draeger.com en
Info
Information pertaining to the measuring device – e.g. type, manufacturer, software version, serial number
Configuration
1. Clock = set date and time
2. Leak Auto Start = activation of the automatic start for leak rate measurement
3. P Damping = selection of the damping value for the pressure measurement
4. Backlight = adjust backlight
5. Key beep = switch key tone on/off
6. Auto Switch Off = selection of the time before the device goes into standby mode
7. Printer = selection of printer protocol and printout of customer and tester
8. Touch pad = calibration of the touchpad
9. Info window = switching the swipe effects on and off in the info window
10. Enable delete function = allow a single measurement dataset to be deleted
11. Language = language selection for the display texts
The device is only intended for the applications described here. To ensure proper functioning and accurate
measurements, the device must be inspected and recalibrated once a year by an authorized service center.
EC regulations pertaining to the disposal of electrical and electronic equipment have been effective since 2005.
In essence, these regulations govern the establishment of collection and recycling facilities for private users.
Given that the Dräger P7 is not registered for use in private households, it is also not permitted to be disposed
of using these channels.
The Dräger P7 can be returned to your national retailer or to your national Dräger Safety Organization for
disposal. Please contact the Dräger MSI GmbH if you have any questions regarding disposal.
Accessories and consumables
Single pipe cover DN 25 5600842
Single pipe cover DN 40 5600985
½” adapter 5600813
Gas pressure hose 5600365
High pressure hose 5600821
Low pressure hose 5610693
Pump hose 5610692
High pressure gas distributor 5610691
Pump adapter 10 bar 5600882
Pump adapter 150 mbar 5600876
Pressure sensor EP35 (3.5 bar) 5600875
Pressure sensor EP250 (25 bar) 5600877
Hand pump 5600880
Equipment case P7 series 5600968
Plug-in charger P7 5680106
Printer with infrared data transmission 5600401
Printer paper for printer 5690151

Other manuals for P7-TD

1

Other Dräger Measuring Instrument manuals

Dräger JM-103 User manual

Dräger

Dräger JM-103 User manual

Dräger Polytron RC001 User manual

Dräger

Dräger Polytron RC001 User manual

Dräger Interlock 7500 DVI User manual

Dräger

Dräger Interlock 7500 DVI User manual

Dräger REGARD User manual

Dräger

Dräger REGARD User manual

Dräger E-Cal station User manual

Dräger

Dräger E-Cal station User manual

Dräger Polytron 5000 User manual

Dräger

Dräger Polytron 5000 User manual

Dräger Pac 3000 User manual

Dräger

Dräger Pac 3000 User manual

Dräger Alcotest 5820 User manual

Dräger

Dräger Alcotest 5820 User manual

Dräger Interlock 7000 User manual

Dräger

Dräger Interlock 7000 User manual

Dräger X-AM 2500 User manual

Dräger

Dräger X-AM 2500 User manual

Dräger MP04551 User manual

Dräger

Dräger MP04551 User manual

Dräger Drager-Tube CH 26303 User manual

Dräger

Dräger Drager-Tube CH 26303 User manual

Dräger FG7000 User manual

Dräger

Dräger FG7000 User manual

Dräger X-am 5600 User manual

Dräger

Dräger X-am 5600 User manual

Dräger PIR 3000 User manual

Dräger

Dräger PIR 3000 User manual

Dräger Alcotest 5000 User manual

Dräger

Dräger Alcotest 5000 User manual

Dräger Bio-Check F User manual

Dräger

Dräger Bio-Check F User manual

Dräger Alcotest 6000 User manual

Dräger

Dräger Alcotest 6000 User manual

Dräger Flow Check User manual

Dräger

Dräger Flow Check User manual

Dräger Polytron 7000 User manual

Dräger

Dräger Polytron 7000 User manual

Dräger X-am 1/2/5000 User manual

Dräger

Dräger X-am 1/2/5000 User manual

Dräger X-zone 5000 Owner's manual

Dräger

Dräger X-zone 5000 Owner's manual

Dräger CH 00213 User manual

Dräger

Dräger CH 00213 User manual

Dräger CMS User manual

Dräger

Dräger CMS User manual

Popular Measuring Instrument manuals by other brands

Diesella 15305138 operating instructions

Diesella

Diesella 15305138 operating instructions

ASAIR AFM0725 instruction manual

ASAIR

ASAIR AFM0725 instruction manual

Extech Instruments C015 user manual

Extech Instruments

Extech Instruments C015 user manual

Wisi WA 8000C user manual

Wisi

Wisi WA 8000C user manual

Mannesmann 99995 instruction manual

Mannesmann

Mannesmann 99995 instruction manual

Lampa 38862 manual

Lampa

Lampa 38862 manual

Status Pro T430 user guide

Status Pro

Status Pro T430 user guide

Dexcom G4 Professional user guide

Dexcom

Dexcom G4 Professional user guide

AcoustX D2 quick start guide

AcoustX

AcoustX D2 quick start guide

OWL KIT-FO4B-WSMDst Quick reference guide

OWL

OWL KIT-FO4B-WSMDst Quick reference guide

STENROC X-80 operating manual

STENROC

STENROC X-80 operating manual

Samson 2162 Parts and technical service guide

Samson

Samson 2162 Parts and technical service guide

Romus BC-05 operating manual

Romus

Romus BC-05 operating manual

UPRtek MK350N PLUS User manual and warranty

UPRtek

UPRtek MK350N PLUS User manual and warranty

Panasonic KW2M-A user manual

Panasonic

Panasonic KW2M-A user manual

Grundfos Conex DIA-2 Installation and operating instructions

Grundfos

Grundfos Conex DIA-2 Installation and operating instructions

Elma BM 52Xs user manual

Elma

Elma BM 52Xs user manual

YSI 550A manual

YSI

YSI 550A manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.