manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. DTS
  6. •
  7. Lighting Equipment
  8. •
  9. DTS XR 5 WASH User manual

DTS XR 5 WASH User manual

Other DTS Lighting Equipment manuals

DTS HORUS FULL COLOUR User manual

DTS

DTS HORUS FULL COLOUR User manual

DTS FREELINE 30 User manual

DTS

DTS FREELINE 30 User manual

DTS MOON 1200 User manual

DTS

DTS MOON 1200 User manual

DTS Scena LED 150 User manual

DTS

DTS Scena LED 150 User manual

DTS PROFILO LED 80 User manual

DTS

DTS PROFILO LED 80 User manual

DTS Z8 User manual

DTS

DTS Z8 User manual

DTS Nick Wash 600 User manual

DTS

DTS Nick Wash 600 User manual

DTS JACK User manual

DTS

DTS JACK User manual

DTS XR2000 BEAM User manual

DTS

DTS XR2000 BEAM User manual

DTS XR1200 WASH Fresnel User manual

DTS

DTS XR1200 WASH Fresnel User manual

DTS NICK NRG 1201 User manual

DTS

DTS NICK NRG 1201 User manual

DTS DELTA 12 HEAD User manual

DTS

DTS DELTA 12 HEAD User manual

DTS FOS 100 SOLO FULL RGBW User manual

DTS

DTS FOS 100 SOLO FULL RGBW User manual

DTS SCENA COMPACT LED 50 User manual

DTS

DTS SCENA COMPACT LED 50 User manual

DTS Alchemy 7 User manual

DTS

DTS Alchemy 7 User manual

DTS ARTEMIO FRESNEL User manual

DTS

DTS ARTEMIO FRESNEL User manual

DTS Scena LED 150 User manual

DTS

DTS Scena LED 150 User manual

DTS XR 8 Wash User manual

DTS

DTS XR 8 Wash User manual

DTS 03.P16.02.01.LED PAR16 LED MR16 BLACK User manual

DTS

DTS 03.P16.02.01.LED PAR16 LED MR16 BLACK User manual

DTS NICK NRG1200 CT User manual

DTS

DTS NICK NRG1200 CT User manual

DTS PAR 20 User manual

DTS

DTS PAR 20 User manual

DTS DIVE/R 18 RGB User manual

DTS

DTS DIVE/R 18 RGB User manual

DTS ALCHEMY 5 User manual

DTS

DTS ALCHEMY 5 User manual

DTS NicKWash 600 User manual

DTS

DTS NicKWash 600 User manual

Popular Lighting Equipment manuals by other brands

Life 39.9F70020C quick start guide

Life

Life 39.9F70020C quick start guide

EuroLite LED ML-20 user manual

EuroLite

EuroLite LED ML-20 user manual

LIGMAN OD-50141 installation manual

LIGMAN

LIGMAN OD-50141 installation manual

Home Accents Holiday 1002461144 instructions

Home Accents Holiday

Home Accents Holiday 1002461144 instructions

Experia IRiS Ripple Light instruction manual

Experia

Experia IRiS Ripple Light instruction manual

Erco Gecko Mounting instructions

Erco

Erco Gecko Mounting instructions

Inter-lux ZTA.100.Surface Installation and maintenance instructions

Inter-lux

Inter-lux ZTA.100.Surface Installation and maintenance instructions

Whelen Engineering Company TN Series installation guide

Whelen Engineering Company

Whelen Engineering Company TN Series installation guide

IKEA BJÖRKSPIREA manual

IKEA

IKEA BJÖRKSPIREA manual

Toolland PM 6640 instruction manual

Toolland

Toolland PM 6640 instruction manual

GTD GTD-LP200 user manual

GTD

GTD GTD-LP200 user manual

LIVARNO home 1105-W-UK manual

LIVARNO home

LIVARNO home 1105-W-UK manual

ProLights EclPar IPMFC user manual

ProLights

ProLights EclPar IPMFC user manual

Velvet EVO Series user manual

Velvet

Velvet EVO Series user manual

IDTOLIGHT GENT installation instructions

IDTOLIGHT

IDTOLIGHT GENT installation instructions

MAYTONI S35 installation manual

MAYTONI

MAYTONI S35 installation manual

MaxLite MLFP14DP4535 user manual

MaxLite

MaxLite MLFP14DP4535 user manual

SLV Elektronik 550621 instruction manual

SLV Elektronik

SLV Elektronik 550621 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

XR 5 WASH XR 5 WASH
GB
User Manual Rel 1.1
Le informazioni contenute in questo documento sono state attentamente redatte e controllate. Tuttavia
non è assunta alcuna responsabilità per eventuali inesattezze. Tutti i diritti sono riservati e questo
documento non può essere copiato, fotocopiato, riprodotto per intero o in parte senza previo consenso
scritto della D.T.S.
DTS si riserva il diritto di apportare senza preavviso cambiamenti e modifiche estetiche , funzionali o di
design a ciascun proprio prodotto. D.T.S. non assume alcuna responsabilità sull’uso o sull’applicazione
dei prodotti o dei circuiti descritti.
The information contained in this publication has been carefully prepared and checked. However, no
responsibility will be taken for any errors. All rights are reserved and this document cannot be copied,
photocopied or reproduced, in part or completely, without prior written consent from D.T.S.
D.T.S. reserves the right to make any aesthetic, functional or design modifications to any of its products
without prior notice. D.T.S. assumes no responsibility for the use or application of the products or circuits
described herein.
Les informations contenues dans le présent manuel ont été rédigées et contrôlées avec le plus grand
soin. Nous déclinons toutefois toute responsabilité en cas d'éventuelles inexactitudes. Tous droits
réservés. Ce document ne peut être copié, photocopié ou reproduit, dans sa totalité ou partiellement,
sans le consentement préalable de D.T.S.
D.T.S. se réserve le droit d'apporter toutes modifications et améliorations esthétiques, fonctionnelles ou
de design, sans préavis, à chacun de ses produits. D.T.S. décline toute responsabilité sur l'utilisation ou
sur l'application des produits ou des circuits décrits.
Las informaciones contenidas en este documento han sido cuidadosamenteredactadas y
controladas. Con todo, no se asume ninguna responsabilidad por eventuales inexactitudes.
Todos los derechos han sido reservados y este documento no puede ser copiado, fotocopiado
o reproducido, total o parcialmente, sin previa autorizaciónescrita de D.T.S.
D.T.S. se reserva el derecho a aportar sin previo aviso cambios y modificaciones de carácter
estético, funcional o de diseño a cada producto suyo. D.T.S. no se asume responsabilidad de
ningún tipo sobre la utilización o sobre la aplicació
n de los productos o de los circuitos descritos.
ARC 1200
XR 5 WASH
2
3
INDEX:
1- TECHNICAL FEATURES 4
2- IMPORTANT SAFETY INFORMATION 5
2.1 Fire prevention
2.2 Prevention of electric shock
2.3 Protection against ultraviolet radiation
2.4 Safety
2.5 Level of protection against the penetration of solid and liquid matter
3- MOUNTING THE LAMP 6
3.1 Lamp alignment
4- VOLTAGE AND FREQUENCY 7
5- INSTALLATION 7
5.1 Safety cable
5.2 Protection against liquids
5.3 Movement
5.4 Risk of fire
5.5 Forced ventilation
5.6 Ambient temperature
6- MAINS CONNECTION 8
6.1 Protection
7- DMX SIGNAL CONNECTION 9
7.1 DMX Addresses
7.2 Selecting the DMX address
8- DISPLAY FUNCTIONS 11
9- PAN & TILT SPEED 14
10- FANS SPEED
11- ERROR MESSAGES
12- HIDDEN MENU 15
13- OPENING THE PROJECTOR HOUSING 16
14- PERIODIC CLEANING
14.1 Lenses and reflectors
14.2 Fans and air passages
15- PERIODIC CONTROLS
16- DMX PROTOCOLS 17
17-COLOUR WHEEL 22
ARC 1200
XR 5 WASH
4
1- TECHNICAL FEATURES
The XR 5 Wash is fitted with a Philips MSD 250/2 discharge lamp
(GY9,5 lampholder base), with a colour temperature of 8500 °K and a luminous flux of
18,000 Lumens.
Average lifespam is 2000 hours, with replacement recommended before 2200 hours
Other recommended lamps: Osram HSD 250/2, GE CSD 250/2.
The unit incorporates:
Power supply
Electromagnetic ballast: 230 V (50/60 Hz) standard. On request 110 V 50/60 Hz.
Power consumption 350 W
Remote Lamp on/off via DMX
Operating ambient temperature -10° / 40°
Weight
20 Kg
Motorized zoom (13°-23°), rotating and indexable beam shaper (0°-170°), frost filter, 2
colour conversion filters (3.200°K and 5.600°K), CMY colour generation + a colour wheel (6
dichroic filters + open, with linear selection, and electronic or electromagnetic ballast.
Optical group
Fresnel lens Ø 150 mm (Borosilicate dichroic parabolic reflector)
Zoom
Motorized zoom (13°-23°)
Dimmer / shutter / strobo
Linear dimmer - Shutter - Strobe from 0,85 flash/sec to 10 flash/sec
Colours
CMY color generation system with 3 palettes for gradual and linear insertion +
colour wheel (6 colours + open). Color change with blackout sync
Effects
Rotating and indexable beam shaper (0°-170°)
Colour conversion filters
3.200°K and 5.600°K
Pan / Tilt
Pan 540° (3,9 sec.) Tilt 270° (2,6 sec.) 16-bit resolution
16 DMX channels
Connections
4 XLR connectors (In and Out) with 3 and 5 pins.
Packing Dimensions
(HxWxL)
550 x 440 x 880 mm
Weight
27 Kg
540 mm
027 °
45mm
1 408 mm
33m6 m
5 0 mm
5
423 mm
ARC 1200
XR 5 WASH
5
2- IMPORTANT SAFETY INFORMATION
2.1 Fire prevention:
The use of any other alternative lamp is not recommended and will null and void the fixture's warranty.
-Never locate the fixture on any flammable surface.
-Minimum distance from flammable materials: 1 MT.
-Minimum distance from the closest illuminable surface: 2 MT.
-Replace any blown or damaged fuses only with fuses of identical value. Refer to the wiring diagram if
there is any doubt.
-Connect the projector to mains power via a thermal magnetic circuit breaker.
2.2 Prevention of electric shock:
-High voltage is present inside the unit. Unplug the unit prior to performing any function which involves
touching the inside of the moving head, including lamp replacement.
-The level of technology present in the Xr5 requires the assistance of specialised personnel for all
servicing. Please refer to an authorised DTS service centre.
-A good earth connection is essential for proper functioning of the projector.
-Never connect the unit without proper earth connection.
-The fixture should be located in places with a good air ventilation.
2.3 Protection against ultraviolet radiation:
-Never turn on the lamp if any of the lenses, filters or ABS covering is damaged. Their respective
shielding functions will only operate efficiently if they are in perfect working order.
-Never look directly the lamp when it is on.
2.4 Safety:
-The projector should always be installed with bolts, clamps and other tools that are capable of
supporting the weight of the unit.
-Always use a second safety cable to sustain the weight of the unit in case of the failure of the main
fixing point.
-The external surface of the unit, at various points, may exceed 70°C. Never handle the unit until at
least 10 minutes have elapsed since the lamp was turned off.
-Always replace the lamp if any physical damage is evident.
-Never install the fixture in an enclosed area lacking sufficient air flow. The ambient temperature should
not exceed 40°C.
-A hot lamp may explode, so always wait for at least 10 minutes prior to attempting to replace the lamp.
-Always wear suitable hand protection when handling the lamp.
2.5 Level of protection against the penetration of solid and liquid matter:
-The projector is classified as an ordinary appliance and its protection level against the penetration of
solid and liquid matter is IP 20.
XR5 can fit a Philips MSD250/2 or a Osram HSD250/2 or a GE CSD250/2.
ARC 1200
XR 5 WASH
3- MOUNTING THE LAMPS
Warning: Switch off the unit before replacing the lamp.
1) Using a screwdriver, remove the 3 screws X,Y, Z, (photo 1) which fix the lamp holder.
2) Remove the lamp holder assembly and insert the lamp (photo 2).
The lamp used on XR 5 is made in quartz glass and should be handled with care. Always follow the
instructions supplied in the lamp's packaging. Never touch the glass directly but use the tissue provided
in the lamp's packaging. The GY9,5 lamp socket is not symmetrical.
DO NOT USE UNDUE FORCE ON THE GLASS. In case of difficulty, read again the instructions and repeat
the procedure.
3) Replace the lamp assembly and tighten the screws X,Y,Z, which were previously removed (photo3).
3.1 Lamp alignment
Attention: we recommend to align the lamp in the optical system to avoid overheating of the dichroic
filters and other components inside the unit.
Alignment is carried out using the 3 adjusters A, B and C.
During this operation you must have a uniform luminosity all around the projected area.
Philips MSD250/2
Power 250W
Luminous flux 18.000 lm
Colour temperature 8.500°K
Lampbase GY9,5
Rated life 3,000 hours
6
Photo 2Photo 1 Photo 3
Photo 5
ARC 1200
XR 5 WASH
4- VOLTAGE AND FREQUENCY
The XR5 with electromagnetic ballast can operate at 230 VOLT 50-60 Hz (110 VOLT 50-60 Hz on
request)
5- INSTALLATION
XR5 may be either floor or ceiling mounted.
For floor mounting installations, the XR5 is supplied with four rubber mounting feet on the base.
For ceiling mounted installations, we reccomend the use of appropriate clamps to fix the unit to the
mounting surface.
The supporting structure from which the unit is hung should be capable of bearing the weight of the
unit, as should any clamps used to hung it. The structure should also be sufficiently rigid so as not to
move or shake whilst the XR5 is moving.
Four quarter turn fast locks placed on the base of the units,allows by using the two fast lock C clamps
provided in the box, to fix the unit in any position.
.
5.1- Safety cable
We recommend the use of a safety cable or chain connected to the Xr5 and to the suspension truss in
order to avoid the fixture accidentally falling should the main fixing point fail. Make sure that the iron
cable or chain can bear the weight of the entire unit.
You may attach the safety chain to the two holes (A) located on the base of the fixture, as shown in the
picture below.
5.2- Protection against liquids
The projector contains electric and electronic components which should under no circumstances come
into contact with oil, water or any other liquid. The proper unit functioning would be compromised
should this occur.
7
A
ARC 1200
XR 5 WASH
5.3- Movement
The projector has a maximum movement of 540° for Pan and 270° for Tilt. DO NOT place any
obstructions in the path of the projector's movement.
5.4- Risk of fire
Each fixture produces heat and must be installed in a well-ventilated place. The minimum recommended
distance from flammable material is 1 MT.
Minimum distance from the object being illuminated is 2 MT.
5.5- Forced ventilation
You will note, on inspection, that the unit features various air inlets and cooling fans located on both the
base and head of the fixture. These should, under no circumstances, be blocked or obstructed whilst the
projector is in operation.
Doing so could cause the fixture to seriously overheat thereby compromising its proper operation.
5.6- Ambient temperature
The projector should never be installed in places that lack a constant air flow. The ambient temperature
should NOT exceed 40°C.
6- MAINS CONNECTION
XR5 with electromagnetic ballast operate at 230 VOLT 50-60 Hz.
Prior to connecting the unit to your mains supply,
ensure that the model in your possession correctly matches
the mains supply available. For connection purposes,
ensure that your plug is capable of supporting 3,15 amps at 230V,
Strict adherence to regulatory norms is strongly recommended.
6.1- Protection
The use of a thermal magnetic circuit breaker is recommended for each XR 5.
A good earth connection is essential for the correct operation of the projector.
7- DMX SIGNAL CONNECTION
The unit operates using the digital DMX 512 (1990) signal. Connection between the mixer and the
projector or between projectors must be carried out using a two pair screened ø 0.5 mm cable and a
CANNON XLR 5 or 3 pins connector.
8
540°
270°
Electromagnetic ballast
230V 50 / 60Hz
ARC 1200
XR 5 WASH
Ensure that the conductors do not touch each other.Do not connect the cable ground to the XLR chassy
The plug housing must be isolated. Connect the mixer signal to the DMX IN projector plug and connect it
to the next projector by connecting the DMX OUT plug on the first projector to the DMX IN plug of the
second one.
In this way, all the projectors are cascade connected.
NB. If the display showing the DMX address flashes, then one of the following errors has occurred:
- DMX signal not present
- DMX address not valid
- DMX reception problem
For Installations where long distance DMX cable connections are needed,we suggest to use a DMX
terminator.
The DMX terminator is a male XLR 3-5 pins connector with a 120 ohm resistor
Between pin 2 and 3.
The DMX terminator must be plugged into the last unit (DMX out panel connector) of the DMX line.
5
3
4 2
11=GND
2=DATA-
3=DATA+
CONTROLLER
S T A N D A R D
DM X 5 1 2
1
2
3
5
4
OUT
120 ohm
PIN 3
PIN 2
PLACE A 120 OHM RESISTOR BETWEEN PIN 2
AND 3 OF A MALE XRL CONNECTOR AND PLUG IT
INTO THE DMX OUT PANEL CONNECTOR OF THE
LAST UNIT CONNECTED TO THE DMX LINE
9ARC 1200
XR 5 WASH
7.1-DMX Addresses
XR 5 Wash have 16 DMX channels.
Set the following addresses on the mixer:
Projector 1 A001
Projector 2 A017 If you want to select the next projector, just add “16”
Projector 3 A033
….. A….
projector 6 A081
7.2-Selecting the DMX address
1) Press the UP-DOWN key until you reach the required DMX channel. The numbers on the display will
start to flash (but the new DMX address hasn't yet been set).
2) Press ENTER to confirm your selection. The numbers on the display will stop flashing and the
projector is now setted to the new DMX address.
TRICKS:
if you keep pushed the UP or DOWN keys, the channels are calculated more quickly and you get a
faster selection.
10 ARC 1200