SDM230A/D/DR/BI
Single Phase Two Wires Din Rail Energy Meter
Technical Data
Safety Instructions
Information for your own safety
This manual does not contain all of the safety measures for operation of
the equipment(module,device),because special operating conditions,
and local code requirements or reg ulati on s may necessitate further
measures. However,it does contain infor mation which must be read
for your personal safety and to avoid material damages.This information
is highlig hted by a wa rning triangle and is repr esented as fol lows,
depending on the degree of potential danger.
Warning
This means that failure to observe the instruction can result in
death, serious injury or considerable material damage.
Caution
Thi s means haza rd of electric shoc k and fai lure to ta ke the
necessary safety precautions will result in death,serious injury
or considerable material damage.
Qualified personnel
Operation of the equipment (module, device) described in this manual
may only be performed by qualified personnel. Qualified personnel in
thi s manua l mea ns pers on who are authorized to commission, start
up, ground and label devices,systems and circuits according to safety
and Regulatory standards.
Use for the intended purpose
The equipment (device, module) may only be used for the application
specified in the catalogue and the user manual,and only be connected
with devices and components recommended and approved by EASTRON.
Proper handling
The prerequisites for perfect, reliable operation of the product are proper
transport, proper storage, installation and assembly, as well as proper
operation and maintenance. When operating electrical equipment, certain
parts of this equipment automatically carry dangerous voltages. Improper
handling can therefore result in serious injuries or material damage.
Use only insulating tools.
Do not connect while circuit is live (hot).
Place the meter only in dry surroundings.
Do not mount the meter in an explosive area or expose the meter
to dust, mildew and insects.
Make sure the used wires are suitable for the maximum current of
this meter.
Make sure the AC wires are connected correctly before activating
the current/voltage to the meter.
Do not touch the meter connecting clamps directly with your bare
hands, with metal, blank wire or other material as you may get an
electrical shock.
Make sure the protection cover is placed after installation.
Installation, maintenance and reparation should only be done by
qualified personnel.
Never break the seals and open the front cover as this might influence
the functionality of the meter, and will avoid any warranty.
Do not drop, or allow physical impact to the meter as there are high
precision components inside that may break.
Performance criteria
Operating humidity
Storage humidity
Operating temperature
Storage temperature
Active energy accuracy
Protection against penetration
of dust and water
Insulating encased meter of
protective class
Warm up time
Mechanical environment
Electromagnetic environment
Degree of pollution
≤ 90%
≤ 95%
-25°C - +55°C
-40°C - +70°C
Class B EN50470-1/3
Class 1 IEC 62053-21
IP51
II
10S
M1
E2
2
Specifications
Nominal voltage(Un)
Operational voltage
Insulation capabilities
- AC voltage withstand
- Impulse voltage withstand
Basic current (Ib)
Maximum rated current (Imax)
Operational current range
Over current withstand
Operational frequency range
Internal power consumption
Test output flash rate (PULSE LED)
Test pulse output rate
Max. reading
230V AC
80%~120% Un
4KV for 1 minute
6KV-1.2µS
10A
100A
0.4% Ib~Imax
30Imax for 0.01s
50Hz ± 10%
≤ 2W/10VA/phase
1000imp/kWh
1000imp/kWh
99999.9 (SDM230D)
999999.9(SDM230A/DR/Bi)
Introduction
JIAXING EA STRON ELECTRONIC INST RUMEN TS CO., LTD.
Add: No.1369 Chengnan Road, Nanhu, Jiaxing, Zhejiang, 314001, China
Tel: +86-573-83698881 /83698882 Fax: +86-573-83698883
Email:sales@eastrongroup.com Web:www.eastron.com.cn www.eastrongroup.com
Dimensions
The SDM230* series are single phase two wire energy meters “with a
white back-lighted LCD screen for prefect reading”. they are used to
measure single phase energy in residential and commercial applications.
The series contains 4 models: SDM230A, SDM230D,
SDM230DR,SDM230Bi
SDM230A : 1P2W energy meter with analog register
SDM230D : 1P2W energy meter with LCD display
SDM230DR: 1P2W energy meter with resettable partial energy
SDM230Bi : 1P2W energy meter with bi-directional measurement
SDM230DR and SDM230Bi have been MID approved. They measures
both active energy (kWh) and power (W). There are two buttons on the
front panel, one is used to scroll the info pages, another to reset partial
energy information. All models has a pulse output, which is passive type.
The constant is 1000imp/kWh.
Height
Width
Depth
99mm
36mm
63mm
36mm
63mm
99mm
35mm
45mm
56
7
8
9
Operation
Wiring Diagram
JIAXING EA STRON ELECT RONIC INST RUMEN TS CO., LTD.
Add: No.1369 Chengnan Road, Nanhu, Jiaxing, Zhejiang, 314001, China
Tel: +86-573-83698881 /83698882 Fax: +86-573-83698883
Email:sales@eastrongroup.com Web:www.eastron.com.cn www.eastrongroup.com
Installation Diagram
Conformity Declaration
We Jiaxing Eastron Electronic Instruments Co.,ltd.
Declare under our sole responsibility as manufacturer that the single phase
active import/export (kWh) indoor el e c t r i c i t y m e t e r S DM230*
cor respond to the production model described in the EC-type examination
certificate and to the requirements of the Directive 2004/22/EC type
Examination Certificate no.0120/SGS0206
Identification Number of the Nb0120
Conformity Declaration
( MID version meters only)
Conformity Declaration
Both SDM230DR and SDM230Bi provide a function of resettable energy.
User can press the right button for 3 seconds to reset the partial
energy.
Resettable Energy
DIN Rail
35mm
N-in
N-out
L-out
L-in
3
4
1
2
Display info
SDM230A, equipped with a 6+1 register counter, measures and displays
active energy (kWh).
SDM230D, equipped with a LCD display, measures and displays active
energy (kWh). The initial reading starts from 0000.00 (4+2) , once it is go
up to 9999.99, the reading will change to 00000.0 (5+1). The max. reading
is 99999.9kWh.
SDM230DR with a white backlit LCD screen for perfect reading is used to
measure single phase energy (kWh) and power (W). The unit provides
also a resettable partial energy.
SDM230Bi, Equipped with white backlit LCD, the unit measures and
displays bi-direction active energy (kWh) and power (W). Resettable
partial energy function is also available.
Buttons
There are two buttons on the front panel of SDM230DR and SDM230Bi:
Scroll display
SDM230DR Information Pages:
0
This button is used to scroll the information pages.
This button is used to reset the partial energy information.
SDM230Bi Information Pages:
Initialization display
When SDM230DR and SDM230Bi is powered on, it will initialize and
do self-checking:
Full Screen Software version Default page
0
SDM230A/D
7:
8: + SDM230DR/Bi
8:
9:
10:
+
COM
1
2+
7
8
9
10

This manual suits for next models

4

Other Eastron Measuring Instrument manuals

Eastron SDM630-EV User manual

Eastron

Eastron SDM630-EV User manual

Eastron SDM220-MBUS User manual

Eastron

Eastron SDM220-MBUS User manual

Eastron SDM120 Modbus User manual

Eastron

Eastron SDM120 Modbus User manual

Eastron SDM72CT-M User manual

Eastron

Eastron SDM72CT-M User manual

Eastron SDM230-Modbus User manual

Eastron

Eastron SDM230-Modbus User manual

Eastron SDM230-Modbus User manual

Eastron

Eastron SDM230-Modbus User manual

Eastron DCM230 User manual

Eastron

Eastron DCM230 User manual

Eastron SDM530Y User manual

Eastron

Eastron SDM530Y User manual

Eastron SDM120 Series User manual

Eastron

Eastron SDM120 Series User manual

Eastron SDM630M CT User manual

Eastron

Eastron SDM630M CT User manual

Eastron DCM230 User manual

Eastron

Eastron DCM230 User manual

Eastron SDM230-LoRaWAN User manual

Eastron

Eastron SDM230-LoRaWAN User manual

Eastron SDM72CT-M User manual

Eastron

Eastron SDM72CT-M User manual

Eastron SDM630-Modbus MID V2 User manual

Eastron

Eastron SDM630-Modbus MID V2 User manual

Eastron SDM120-CT-MV User manual

Eastron

Eastron SDM120-CT-MV User manual

Eastron SDM630MCT Series User manual

Eastron

Eastron SDM630MCT Series User manual

Eastron SDM120 Series User manual

Eastron

Eastron SDM120 Series User manual

Eastron SDM630Pulse User manual

Eastron

Eastron SDM630Pulse User manual

Eastron SDM630-Mbus V2 User manual

Eastron

Eastron SDM630-Mbus V2 User manual

Eastron SDM630MCT-MBUS V2 User manual

Eastron

Eastron SDM630MCT-MBUS V2 User manual

Eastron SDM72D User manual

Eastron

Eastron SDM72D User manual

Eastron SDM530-MT User manual

Eastron

Eastron SDM530-MT User manual

Eastron SDM630MCT-RC User manual

Eastron

Eastron SDM630MCT-RC User manual

Eastron SDM630-Mbus V2 User manual

Eastron

Eastron SDM630-Mbus V2 User manual

Popular Measuring Instrument manuals by other brands

ADInstruments DTVLINK-5 user manual

ADInstruments

ADInstruments DTVLINK-5 user manual

Test Equipment Depot 8901 Operation manual

Test Equipment Depot

Test Equipment Depot 8901 Operation manual

Druck DPI 705 Calibration instructions

Druck

Druck DPI 705 Calibration instructions

konf emLas user guide

konf

konf emLas user guide

Extech Instruments 475040 user guide

Extech Instruments

Extech Instruments 475040 user guide

YSI SonTek FlowTracker quick start guide

YSI

YSI SonTek FlowTracker quick start guide

Laser Technology MapStar TruAngle user manual

Laser Technology

Laser Technology MapStar TruAngle user manual

Pfeuffer Vario 1G operating instructions

Pfeuffer

Pfeuffer Vario 1G operating instructions

Deepace KC901V manual

Deepace

Deepace KC901V manual

triOS OSCAR G2 manual

triOS

triOS OSCAR G2 manual

Lufkin LLM45 user guide

Lufkin

Lufkin LLM45 user guide

3B Elettronica 8110-AIR5 user manual

3B Elettronica

3B Elettronica 8110-AIR5 user manual

Phoenix Contact EMpro EEM-MA371 Installation notes for electricians

Phoenix Contact

Phoenix Contact EMpro EEM-MA371 Installation notes for electricians

Ametek 5100 HD user manual

Ametek

Ametek 5100 HD user manual

Konica Minolta CIVI-36clG instruction manual

Konica Minolta

Konica Minolta CIVI-36clG instruction manual

Piston PDD-401 Operation manual

Piston

Piston PDD-401 Operation manual

GasLab TecPen user manual

GasLab

GasLab TecPen user manual

Hach POCKET COLORIMETER II LCK 325 Application Instruction

Hach

Hach POCKET COLORIMETER II LCK 325 Application Instruction

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.