Eaton CurrentWatch EGF Series Manual

CurrentWatch™ EGF Series Ground Fault Sensors
120 VAC Powered, N.O. or N.C.,
Solid State Relay Output
WARNING
IN ORDER TO AVOID ELECTRIC SHOCK OR OTHER POSSIBLE
INJURY:
• DO NOT USE THIS PRODUCT FOR HUMAN SAFETY
APPLICATIONS. IT WAS NOT DESIGNED, TESTED, OR
RECOMMENDED FOR THIS USE.
• DO NOT USE THIS PRODUCT IN HAZARDOUS LOCATIONS
(E.G. EXPLOSIVE ATMOSPHERES). IT WAS NOT DESIGNED,
TESTED, OR RECOMMENDED FOR THIS USE.
• ENSURE THE PRODUCT IS PROPERLY WIRED TO THE
CORRECT POWER SUPPLY FOR THE APPLICATION. REFER
TO THE SPECIFICATIONS AND WIRING DIAGRAMS IN THIS
PUBLICATION.
Models Covered In This Publication
Catalog Number Description
EGF1NOACNE050 N.O. 1 A @ 240 VAC, Normally Energized, 50 mA Range
EGF1NOACDE050 N.O. 1 A @ 240 VAC, Normally De-Energized, 50 mA Range
EGF1NCACNE050 N.C. 1 A @ 240 VAC, Normally Energized, 50 mA Range
EGF1NCACDE050 N.C. 1 A @ 240 VAC, Normally De-Energized, 50 mA Range
EGF1NOACNE100 N.O. 1 A @ 240 VAC, Normally Energized, 100 mA Range
EGF1NOACDE100 N.O. 1 A @ 240 VAC, Normally De-Energized, 100 mA Range
EGF1NCACNE100 N.C. 1 A @ 240 VAC, Normally Energized, 100 mA Range
EGF1NCACDE100 N.C. 1 A @ 240 VAC, Normally De-Energized, 100 mA Range
EGF1NODCNE050 N.O. 0.15 A @ 30 VDC, Normally Energized, 50 mA Range
EGF1NODCDE050 N.O. 0.15 A @ 30 VDC, Normally De-Energized, 50 mA Range
EGF1NCDCNE050 N.C. 0.15 A @ 30 VDC, Normally Energized, 50 mA Range
EGF1NCDCDE050 N.C. 0.15 A @ 30 VDC, Normally De-Energized, 50 mA Range
Instructions Publication P51925 Effective July 2017
Supersedes March 2014
Instruction Leaflet
Montageanweisung
Notice d’installation
Instrucciones de montaje
Istruzioni per il montaggio
安装说明
Инструкция по монтажу
Montagehandleiding
Montagevejledning
Οδηγίες εγκατάστασης
Instruções de montagem
Monteringsanvisning
Asennusohje
Návod k montáži
Paigaldusjuhend
Szerelési utasítás
Montāžas instrukcija
Montavimo instrukcija
Instrukcja montażu
Navodila za montažo
Návod na montáž
Монтажни инструкции
Instrucţiuni de montaj
Upute za montažu
Electric current! Danger to life!
Only skilled or instructed persons may
carry out the following operations.
Lebensgefahr durch elektrischen Strom!
Nur Elektrofachkräfte und elektrotechnisch
unterwiesene Personen dürfen die im Folgenden
beschriebenen Arbeiten ausführen.
Tension électrique dangereuse !
Seules les personnes qualifiées et averties doivent
exécuter les travaux ci-après.
¡Corriente eléctrica! ¡Peligro de muerte!
El trabajo a continuación descrito debe ser realizado
por personas cualificadas y advertidas.
Tensione elettrica: Pericolo di morte!
Solo personeabilitate e qualificate possono eseguire
le operazioni di seguito riportate.
触电危险!
只允许专业人员和受过专业训练的人员进行下列工作。
Электрический ток! Опасно для жизни!
Только специалисты или проинструктированные
лица могут выполнять следующие операции.
Levensgevaar door elektrische stroom!
Uitsluitend deskundigen in elektriciteit en
elektrotechnisch geïnstrueerde personen is het
toegestaan, de navolgend beschreven
werkzaamheden uit te voeren.
Livsfare på grund af elektrisk strøm!
Kun uddannede el-installatører og personer der
e instruerede i elektrotekniske arbejdsopgaver,
må udføre de nedenfor anførte arbejder.
en
de
fr
es
it
zh
ru
nl
da
Προσοχή, κίνδυνος ηλεκτροπληξίας!
Οι εργασίες που αναφέρονται στη συνέχεια θα
πρέπει να εκτελούνται μόνο από ηλεκτρολόγους
και ηλεκτροτεχνίτες.
Perigo de vida devido a corrente eléctrica!
Apenas electricistas e pessoas com formação
electrotécnica podem executar os trabalhos
que a seguir se descrevem.
Livsfara genom elektrisk ström!
Endast utbildade elektriker och personer som
undervisats i elektroteknik får utföra de arbeten
som beskrivs nedan.
Hengenvaarallinen jännite!
Vain pätevät sähköasentajat ja opastusta saaneet
henkilöt saavat suorittaa seuraavat työt.
Nebezpečí úrazu elektrickým proudem!
Níže uvedené práce smějí provádět pouze
osoby s elektrotechnickým vzděláním.
Eluohtlik! Elektrilöögioht!
Järgnevalt kirjeldatud töid tohib teostada ainult
elektriala spetsialist vői elektrotehnilise
instrueerimise läbinud personal.
Életveszély az elektromos áram révén!
Csak elektromos szakemberek és elektrotechnikában
képzett személyek végezhetik el a következőkben leírt
munkákat.
Elektriskāstrāva apdraud dzīvību!
Tālāk aprakstītos darbus drīkst veikt tikai
elektrospeciālisti un darbam ar elektrotehniskām
iekārtām instruētās personas!
el
pt
sv
fi
cs
et
hu
lv
Pavojus gyvybei dėl elektros srovės!
Tik elektrikai ir elektrotechnikos specialistai gali
atlikti žemiau aprašytus darbus.
Porażenie prądem elektrycznym stanowi
zagrożenie dla życia!
Opisane poniżej prace mogąprzeprowadzaćtylko
wykwalifikowani elektrycy oraz osoby odpowiednio
poinstruowane w zakresie elektrotechniki.
Življenjska nevarnost zaradi
električnega toka!
Spodaj opisana dela smejo izvajati samo
elektrostrokovnjaki in elektrotehnično poučene osebe.
Nebezpečenstvo ohrozenia života
elektrickým prúdom!
Práce, ktoré sú nižšie opísané, smú vykonávat’
iba elektroodborníci a osoby s elektrotechnickým
vzdelaním.
Опасност за живота от електрически ток!
Операциите, описани вследващите раздели,
могат да се извършват само от
специалисти-електротехници иинструктиран
електротехнически персонал.
Atenţie! Pericol electric!
Toate lucrările descrise trebuie efectuate numai
de personal de specialitate calificat şi de persoane
cu cunoştiinţe profunde în electrotehnică.
Opasnost po život uslijed električne struje!
Radove opisane u nastavku smiju obavljati samo
stručni električari i osobe koje su prošle
elektrotehničku obuku.
lt
pl
sl
sk
bg
ro
hr
490020207
Catalog Number Description
EGF1NODCNE100 N.O. 0.15 A @ 30 VDC, Normally Energized, 100 mA Range
EGF1NODCDE100 N.O. 0.15 A @ 30 VDC, Normally De-Energized, 100 mA Range
EGF1NCDCNE100 N.C. 0.15 A @ 30 VDC, Normally Energized, 100 mA Range
EGF1NCDCDE100 N.C. 0.15 A @ 30 VDC, Normally De-Energized, 100 mA Range
EGF3NOACNET3 N.O. 1 A @ 240 VAC, Normally Energized, 5/10/30 mA Range
EGF3NOACDET3 N.O. 1 A @ 240 VAC, Normally De-Energized, 5/10/30 mA
Range
EGF3NODCNET3 N.O. 0.15 A @ 30 VDC, Normally Energized, 5/10/30 mA
Range
EGF3NODCDET3 N.O. 0.15 A @ 30 VDC, Normally De-Energized, 5/10/30 mA
Range
EGF3NCACNET3 N.C. 1 A @ 240 VAC, Normally Energized, 5/10/30 mA Range
EGF3NCACDET3 N.C. 1 A @ 240 VAC, Normally De-Energized, 5/10/30 mA
Range
EGF3NCDCNET3 N.C. 0.15 A @ 30 VDC, Normally Energized, 5/10/30 mA
Range
EGF3NCDCDET3 N.C. 0.15 A @ 30 VDC, Normally De-Energized, 5/10/30 mA
Range
Introduction
The CurrentWatch™ EGF Series is a family of ground fault (earth
leakage) sensors. Ground fault sensors help protect people, prod-
ucts, and processes from damage by ground fault conditions by
monitoring all current-carrying conductors in grounded single- and
three-phase delta or wye systems. They provide a contact output
that can operate relays, contactors or signal automation systems.
ote:N This manual only covers solid state versions of the EGF Series (listed
in the table above). For installation manuals covering other models in the EGF
Series family, please contact Eaton Sensor Application Engineers.
Quick Install Guide
The below steps can be followed to quickly install a CurrentWatch
EGF Series switch.
1. Run all current carrying conductors through sensor window,
using an auxiliary current transformer if conductors do not fit.
2. Mount the sensor to a surface if needed.
3. Connect output and power wiring:
a. Use up to 14 AWG copper wires,
b. Ensure power and load matches those shown on the sensor
label.
4. Test the unit
a. Pressing the “TEST” button will test the sensor’s internal
circuits
(CAUTION: The output and any connected loads will
switch during the test process)
Installation and Wiring
Considerations for installing and wiring EGF Series sensors…
• Run wire to be monitored through the aperture (opening) in the
switch body, making sure all wires are oriented so that current
flows in the same direction (see “Principal of Operation” section
below).
• These sensors can be located in the same environment as
motors, contactors, heaters, pull-boxes, and other electrical enclo-
sures.
• Mounting can be done in any position or hung directly on a wire
with a wire tie.
• Be sure to leave at least one in.(25.4 mm) distance between sen-
sor and other magnetic devices.
• Connect power and output wiring to the sensor, using up to 14
AWG copper wire and tightening terminals to 7 in.-lbs / 0.79 N·m
maximum torque.
• Make sure the power supply matches the power rating on the
sensor label.
• Make sure the output load is less than or equal to the output rat-
ing on the sensor label.
PowerOutput
G
X
Control Power
(Match Sensor Rating--See Label)
TEST
(+)
(-)
Power Supply LEDContact Status LED
Load
Contactor, Relay, Shunt Trip Breaker...
(Do Not Exceed Rating--See Label)
Setpoint Adjust
Factory Calibrated and Covered
(Remove Cover, Adjust and
Relabel if Required)
Output Power
(Match Sensor Rating--See Label)
For DC Output Versions...
Observe Polarity
Principal of Operation
Under normal conditions, the current in one wire of a two wire load
is equal in strength but opposite in sign to the current in other wire.
The two wires create magnetic fields that cancel, a condition known
as “Zero Sum Current.” If any current leaks to ground (Ground Fault),
the two currents become unbalances and there is a net resulting
magnetic field. The EGF Series sensor detects this minute field and
change the output state. This concept extends to three phase sys-
tems such as 3-wire Delta and to 4-wire Wye.
Operation
To test operation, gently press the TEST button. This simulates a fault
and tests the internal switching circuits. The following operation should
be observed.
CAUTION: Any circuit connected to the sensor will be operated.
Power Output
Power
Interupt
A
B
C
N
3 W
ye Power
3 Load
Power Output
Power
Interupt
HOT
NEUT
1 Power
1 Load
Power Output
Power
Interupt
A
B
3 Power
1 Load
Power Output
Power
Interupt
A
B
C
3 Delta Power
3 Load
Models Covered In This Publication (Cont.)
2EATON www.eaton.com
CurrentWatch™ EGF Series Ground Fault Sensors
120 VAC Powered, N.O. or N.C.,
Solid State Relay Output
Instructions Publication P51925
Effective July 2017
Normally Energized Models
Used for detecting ground faults and loss of control power.
Output
No Power
Control Power Applied
No Fault Fault Detected
Output LED Output LED Output LED
N.C. Closed Off Open On Closed Off
N.O. Open Off Closed On Open Off
Normally De-Energized Models
Used for detecting ground faults only.
Output
No Power
Control Power Applied
No Fault Fault Detected
Output LED Output LED Output LED
N.C. Closed Off Closed Off Open On
N.O. Open Off Open Off Closed On
Setpoint Adjustment
The EGF Series sensors are factory calibrated to trip at the setpoint
specified by the model number. While it is generally recommended
not to change this setpoint, it can be done by following the below
steps.
1. Connect control power and circuits. Run a conductor through
the aperture with current equal to your desired setpoint.
2. Adjust setpoint to maximum by first removing the setpoint cover.
Turn the adjustment pot four revolutions counter-clockwise to the
maximum (least sensitive) setpoint. The Status LED should be
off. The adjustment pot has a slip clutch so that you cannot feel
or damage the end point.
3. Dial in the new setpoint by slowly turning the pot clockwise until
the LED turns on. The sensor is now adjusted to trip at the cur-
rent that is passing through the aperture. Reset the sensor.
4. Relabel the sensor with a new setpoint. Use a label maker or
tape with a permanent marker.
Power Supply Notes
All low-current ground-fault sensors are sensitive devices that
require reasonable care in system design to avoid false trips caused
by high electrical noise levels. Keep in mind that the best way to
reduce noise in a system is to suppress it at its source.
• Keep the sensor power isolated from noisy circuits.
• Do not power the sensor with the same circuit that switches contac-
tors or other high current inductive loads.
System Grounding
Good design practice and code require that all AC power systems be
grounded. The EGF Series sensors are designed to work on grounded
AC power systems. They may not operate properly on ungrounded sys-
tems.
Specications
Specification Value
Power Supply 120 VAC (Operates from 66-132 V)
Voltage Range Up to 1,500 VAC (Monitored Circuit)
Power Consumption 2.5 W
Output Magnetically Isolated Solid State Switch
Output Rating AC Models:
1 A @ 240 V C (2 A for 10 min.)
DC Models:
0.15 A @ 30 VDC (500 mA Momentary)
Response Time At 5% Over Setpoint: 150 ms
At 50% Over Setpoint: 100 ms
Setpoint Range Models Ending -T3:
5, 10, or 30 mA (Adjustable by Jumper)
All Other Models:
50 or 100 mA (See “Setpoint Adjustment”)
Frequency Range 50-400 Hz (Monitored Circuit)
Housing UL94 V0 Flammability Rated
Dimensions Housing: 2.5 in. H x 2.8 in. W x 1.5 in. D (64 x 71 x 38 mm)
Aperture: 0.75 in. (19 mm)
LED Green = Power Supply Energized
Environmental Operating Temperature: +5 to +158°F (-15 to +70°C)
Humidity: 0-95% RH, Non-Condensing
Approvals UL Recognized, E313337
CE
RoHs Compliant
3
EATON www.eaton.com
Instructions Publication P51925
Effective July 2017
CurrentWatch™ EGF Series Ground Fault Sensors
120 VAC Powered, N.O. or N.C.,
Solid State Relay Output
Eaton Industries GmbH
Hein-Moeller-Straße 7-11,
53115 Bonn, Germany
Eaton Corporation
W126 N7250 Flint Drive
Menomonee Falls,
WI 53051, USA
Contact your regionalEaton oce for additionaltechnical support
Eatonis a registered trademark of
Eaton Corporation.
All other trademarks are property
of their respective owners.
Americas – Asia Pacic Europe – Middle East – Africa
Eaton Corporation
Electrical Sector – Sensors
+1.800.426.9184
www.eaton.com/sensors
Eaton Industries GmbH
Electrical Sector EMEA
+49(0) 180 5 223822
www.eaton.eu/sensors
© 2017 by Eaton
All Rights Reserved
Printed in USA
Publication No. P51925 / 004
July 2017
CurrentWatch™ EGF Series Ground Fault Sensors
120 VAC Powered, N.O. or N.C.,
Solid State Relay Output
Instructions Publication P51925
Effective July 2017
Eaton Industries GmbH
Hein-Moeller-Straße 7-11,
53115 Bonn, Germany
Eaton
W126 N7250 Flint Drive
Menomonee Falls,
WI 53051, USA
Eaton
Electrical Sector – Sensors
+1.800.426.9184
www.eaton.com/sensors
Eaton Industries GmbH
Electrical Sector EMEA
+49 (0) 180 5 223822
www.eaton.eu/sensors
Eaton is a registered trademark.
All other trademarks are property
of their respective owners.
Contact your regional Eaton office for additional technical support
Americas – Asia Pacific Europe – Middle East – Africa

This manual suits for next models

24

Other Eaton Accessories manuals

Eaton E52 Series Manual

Eaton

Eaton E52 Series Manual

Eaton CurrentWatch EGFL Series Manual

Eaton

Eaton CurrentWatch EGFL Series Manual

Eaton CWPD Series User manual

Eaton

Eaton CWPD Series User manual

Eaton Crouse-Hinds GHG 514 User manual

Eaton

Eaton Crouse-Hinds GHG 514 User manual

Eaton 450-CSA Manual

Eaton

Eaton 450-CSA Manual

Eaton CurrentWatch EDC Series Manual

Eaton

Eaton CurrentWatch EDC Series Manual

Eaton CurrentWatch EAC Series User manual

Eaton

Eaton CurrentWatch EAC Series User manual

Eaton Home Heartbeat User manual

Eaton

Eaton Home Heartbeat User manual

Eaton GHG 511 User manual

Eaton

Eaton GHG 511 User manual

Eaton 50 Series User manual

Eaton

Eaton 50 Series User manual

Eaton CurrentWatch EPRM Series User manual

Eaton

Eaton CurrentWatch EPRM Series User manual

Eaton GHG 521 User manual

Eaton

Eaton GHG 521 User manual

Eaton CDWA-01/3 Series Manual

Eaton

Eaton CDWA-01/3 Series Manual

Eaton xComfort CTEU-02/0 Series User manual

Eaton

Eaton xComfort CTEU-02/0 Series User manual

Eaton Water Guard CWGE-0 Series Manual

Eaton

Eaton Water Guard CWGE-0 Series Manual

Eaton E56M Manual

Eaton

Eaton E56M Manual

Eaton xComfort CEMU-01/ Series User manual

Eaton

Eaton xComfort CEMU-01/ Series User manual

Eaton xComfort CEMP-01/1X User manual

Eaton

Eaton xComfort CEMP-01/1X User manual

Eaton CEMU-01/03 User manual

Eaton

Eaton CEMU-01/03 User manual

Eaton CBMD-02 Series Manual

Eaton

Eaton CBMD-02 Series Manual

Eaton GridAdvisor II Series User manual

Eaton

Eaton GridAdvisor II Series User manual

Eaton Crouse-hinds series User manual

Eaton

Eaton Crouse-hinds series User manual

Eaton CurrentWatch EGF Series User manual

Eaton

Eaton CurrentWatch EGF Series User manual

Eaton IntelliView E76 Series Manual

Eaton

Eaton IntelliView E76 Series Manual

Popular Accessories manuals by other brands

AECO SMC-12 NO SS BC HF AGD1 Series operating instructions

AECO

AECO SMC-12 NO SS BC HF AGD1 Series operating instructions

IFM Electronic Efector160 LK3 operating instructions

IFM Electronic

IFM Electronic Efector160 LK3 operating instructions

Schwaiger HOME4YOU ZHS05 user manual

Schwaiger

Schwaiger HOME4YOU ZHS05 user manual

Andis HDB-1 brochure

Andis

Andis HDB-1 brochure

Xiaomi Aqara QBCZ11LM User manual and warranty card

Xiaomi

Xiaomi Aqara QBCZ11LM User manual and warranty card

ipf electronic PRQ80376 manual

ipf electronic

ipf electronic PRQ80376 manual

Tait T830 Series Service manual

Tait

Tait T830 Series Service manual

Autonics BS3 Series product manual

Autonics

Autonics BS3 Series product manual

Digi Connect Sensor user guide

Digi

Digi Connect Sensor user guide

Simplicity Landlord Riding Tractor installation guide

Simplicity

Simplicity Landlord Riding Tractor installation guide

Hytronik HEC9025/I Installation and instruction manual

Hytronik

Hytronik HEC9025/I Installation and instruction manual

Emerson Rosemount 550pH Reference manual

Emerson

Emerson Rosemount 550pH Reference manual

BeeSecure M2D product manual

BeeSecure

BeeSecure M2D product manual

MEFE CAT 139 8101 operating manual

MEFE

MEFE CAT 139 8101 operating manual

brennenstuhl WA 3000 XS02 user manual

brennenstuhl

brennenstuhl WA 3000 XS02 user manual

MONARCH INSTRUMENT ROLS instruction manual

MONARCH INSTRUMENT

MONARCH INSTRUMENT ROLS instruction manual

Lambrecht 14579 operating instructions

Lambrecht

Lambrecht 14579 operating instructions

aci A/CTA2-5 Installation and operation instructions

aci

aci A/CTA2-5 Installation and operation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.