manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Eaton
  6. •
  7. Circuit Breaker
  8. •
  9. Eaton T5B Series Manual

Eaton T5B Series Manual

This manual suits for next models

1

Other Eaton Circuit Breaker manuals

Eaton PKE-SWD-CP Manual

Eaton

Eaton PKE-SWD-CP Manual

Eaton Series NRX Manual

Eaton

Eaton Series NRX Manual

Eaton PKZM0 PI Series Manual

Eaton

Eaton PKZM0 PI Series Manual

Eaton IZM User manual

Eaton

Eaton IZM User manual

Eaton Z-SH Manual

Eaton

Eaton Z-SH Manual

Eaton VCP-W Instruction Manual

Eaton

Eaton VCP-W Instruction Manual

Eaton NZM1-XMV Manual

Eaton

Eaton NZM1-XMV Manual

Eaton DILM -11 -PI Series Manual

Eaton

Eaton DILM -11 -PI Series Manual

Eaton MSC-D XTSE Series Manual

Eaton

Eaton MSC-D XTSE Series Manual

Eaton Power Defense PDG2XPIBB3P225A Manual

Eaton

Eaton Power Defense PDG2XPIBB3P225A Manual

Eaton Crouse-Hinds F892 User manual

Eaton

Eaton Crouse-Hinds F892 User manual

Eaton xComfort CDAU-01/02 User manual

Eaton

Eaton xComfort CDAU-01/02 User manual

Eaton Magnum PXR User manual

Eaton

Eaton Magnum PXR User manual

Eaton Power Defense PD5 Manual

Eaton

Eaton Power Defense PD5 Manual

Eaton Power Defense PDC2 Manual

Eaton

Eaton Power Defense PDC2 Manual

Eaton PFR-5 Manual

Eaton

Eaton PFR-5 Manual

Eaton E-PKZ0 Manual

Eaton

Eaton E-PKZ0 Manual

Eaton PKZM0 SP-65KA Series Manual

Eaton

Eaton PKZM0 SP-65KA Series Manual

Eaton DILM95-XSP XTCERENCOILF Manual

Eaton

Eaton DILM95-XSP XTCERENCOILF Manual

Eaton BZM2 Manual

Eaton

Eaton BZM2 Manual

Eaton IZM6 Series User manual

Eaton

Eaton IZM6 Series User manual

Eaton IZM32 User manual

Eaton

Eaton IZM32 User manual

Eaton PKE12 Series Manual

Eaton

Eaton PKE12 Series Manual

Eaton Roadranger TRSM4106 User manual

Eaton

Eaton Roadranger TRSM4106 User manual

Popular Circuit Breaker manuals by other brands

Siemens 3VT9524-4TG30 quick start guide

Siemens

Siemens 3VT9524-4TG30 quick start guide

Acrel ASCB1 Series Installation and operation manual

Acrel

Acrel ASCB1 Series Installation and operation manual

ABB SACE Emax 2 E2.2 manual

ABB

ABB SACE Emax 2 E2.2 manual

ABB SACE Emax E1 quick start guide

ABB

ABB SACE Emax E1 quick start guide

Siemens SIRIUS 3RV1742 Original operating instructions

Siemens

Siemens SIRIUS 3RV1742 Original operating instructions

WEG FHU ACW125 installation instructions

WEG

WEG FHU ACW125 installation instructions

TERASAKI NHP TemBreak PRO P160 Series installation instructions

TERASAKI

TERASAKI NHP TemBreak PRO P160 Series installation instructions

Siemens Sentron 3VA9157-0PK1 Series operating instructions

Siemens

Siemens Sentron 3VA9157-0PK1 Series operating instructions

hager TS 303 User instruction

hager

hager TS 303 User instruction

ETI EFI-4B Instructions for mounting

ETI

ETI EFI-4B Instructions for mounting

Gladiator GCB150 Installation instruction

Gladiator

Gladiator GCB150 Installation instruction

nader NDM3EU-225 operating instructions

nader

nader NDM3EU-225 operating instructions

ABB SACE Emax 2 E6.2 Instruction handbook

ABB

ABB SACE Emax 2 E6.2 Instruction handbook

Gewiss 90 RCD Installation

Gewiss

Gewiss 90 RCD Installation

OEZ LFN Instructions for use

OEZ

OEZ LFN Instructions for use

Bticino L4412CM2 quick start guide

Bticino

Bticino L4412CM2 quick start guide

OEZ 3VA9-RS-4VBH1 Installation, service and maintenance instructions

OEZ

OEZ 3VA9-RS-4VBH1 Installation, service and maintenance instructions

Siemens PSR Instructions, Installation, Operation, Maintenance

Siemens

Siemens PSR Instructions, Installation, Operation, Maintenance

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Electric current! Danger to life!
Only skilledor instructedpersons may
carry out the following operations.
Lebensgefahr durch elektrischenStrom!
Nur Elektrofachkräfte undelektrotechnisch
unterwiesene Personen dürfen die im Folgenden
beschriebenen Arbeiten ausführen.
Tension électrique dangereuse !
Seules les personnes qualifiées et averties doivent
exécuter les travaux ci-après.
¡Corrienteeléctrica! ¡Peligro de muerte!
El trabajo a continuación descrito debe ser realizado
por personas cualificadas y advertidas.
Tensione elettrica: Pericolo di morte!
Solo persone abilitate e qualificate possono eseguire
le operazioni di seguito riportate.
触触电电危危险险!!
只允许专业人员和受过专业训练的人员进行
下列工作。
Электрический ток!Опасно для жизни!
Только специалисты или проинструктированные
лица могут выполнять следующие операции.
en
de
fr
es
it
zh
ru
Emergency On Call Service:Local representative (www.eaton.eu/aftersales)or +49 (0)180 5223822 (de,en) 1/4
Instruction Leaflet
Montageanweisung
Notice d’installation
Instrucciones de montaje
Istruzioni per il montaggio
安
安装装说说明明
Инструкция по монтажу
07/16 IL03801009Z
(AWA1150-1692, IL00802004E)
T5B…, T5…
T5(B)…/E T5(B)…/EA/SVB
T5(B)…/Z T5(B)…/V/SVB
T5B…/I4 T5B…/I4/SVB
T5…/I5 T5…/I5/SVB
1 x 1.5 - 25 mm2
2 x 1.5 - 10 mm24 Nm (35.5 lb- in)
1 x 2.5 - 35 mm2
2 x 2.5 - 16 mm24 Nm (35.5 lb- in)
UL-File: E36 332
UL AWG 12/4 4 Nm (35.5 lb- in)
UL/CSA:
Suitable For Use As Motor Branch
Circuit Disconnecting Means With
Suffix SVB.
Break All Lines.
Short Circuit Withstand
10 kA RMS SYM 600 V AC
Max Fuse T5B… – 100 Class J
T5… – 100 ClassJ
Standard Short Circuit
5 kA RMS SYM 600 V AC
Max Fuse T5B… – 100 A
T5… – 100 A
Switch or enclosure must be
padlockable if used as a Motor
Branch Circuit Disconnectormeans.
ON
OFF
OFF
ON
ON
OFF
ON
OFF
2/4 Emergency On Call Service: Local representative (www.eaton.eu/aftersales)or +49(0) 1805223822 (de, en)
07/16 IL03801009Z
T5(B)…/E
T5(B)…/EA/SVB(-SW)
T5(B)…/E+SVB(-SW)-P3
H1-T5
T5(B)…/Z, T5(B)…/Z+SVB(-SW)-P3 T5(B)…/V/SVB, T5(B)…/Z+V/EA/SVB(-SW)-T5
ON
OFF
ON
OFF
Fig. 1
FS...-P3
KNB-P3
KNB-RT-P3
ZFS...P3
AE-P3
SVB-P3
SVB-SW-P3
H1-T5
HZ-T5
H1-T5
HZ-T5
≦5 mm
(≦ 0.197”)
UV-P3
1 Nm
(8.85 lb-in)
ST 2.9 x 9.5
0.6 Nm (5.31 lb-in)
ST 2.9 x 9.5
0.6 Nm (5.31 lb-in)
2 x ST 3.9 x 19
1 Nm (8.85 lb-in)
1 Nm
(8.85 lb-in)
d
b
≦3 x d = 4 - 8 mm
b+ d ≦47 mm (d = 0.16 -0.32“)
(b + d ≦1.85“)
ON
OFF
ON
OFF
FS...-P3
ZFS...P3 Fig. 2
Fig. 3
AZ-P3
ZAV-P3
DE-P3
SVB-SW-P3
SVB-P3
4 x ST 3.9 x 19
1 Nm (8.85 lb-in)
4 x ST 3.9 x 19
1 Nm (8.85 lb-in)
1 Nm
(8.85 lb-in)
1 Nm
(8.85 lb-in)
ON
OFF
ZFS...P3
UV-P3
ZVV-P3
(≦ 4)
ZAV-P3
(≦ 4)
Fig. 2
Fig. 3
H1-T5
H1-T5
≦5 mm
(≦ 0.197”)
4 x ST 3.9 x 19
1 Nm (8.85 lb-in)
0.6 Nm
(5.31 lb-in)
1 Nm
(8.85 lb-in)
Emergency On Call Service:Local representative (www.eaton.eu/aftersales)or +49 (0)180 5223822 (de,en) 3/4
07/16 IL03801009Z
T5B…/I4(-RT)
T5B…/I4/SVB(-SW)
Components drawn in broken lines are not included in the scope of delivery.
Gestrichelt gezeichnete Komponenten gehören nicht zum Lieferumfang.
Les éléments représentés en pointillés ne font paspartie de la fourniture.
Los componentes dibujados en líneas discontinuas no están incluídos en
el suministro.
Gil apparechi contrassegnati con un tratteggio con fanno parte della fornitura.
Заштрихованные компоненты не входят в объем поставки.
ON
OFF
ON
OFF
4 x ST 3.9 x 19
1 Nm
(8.85 lb-in)
1 Nm
(8.85 lb-in)
1 Nm (8.85 lb-in)
1 x ST 3.9 x 25
1 Nm (8.85 lb-in)
ZFS...P3 en
de
fr
es
it
zh
ru
ON
OFF
ON
OFF
ZFS...P3
DE-P3
X
Z
Y
4 x ST 3.9 x 19
1 Nm (8.85 lb-in)
1 x ST 3.9 x 25
1 Nm (8.85 lb-in)
T5(B)-1-…
T5(B)-3-…
T5(B)-2-…
T5(B)-4-…
1 Nm
(8.85 lb-in)
1 Nm
(8.85 lb-in)
4 x ST 3.9 x 19
1 Nm (8.85 lb-in)
T5…/I5(-RT)
T5…/I5/SVB(-SW)
c
b
ON
OFF
a
[mm] T5B-1(2) T5B-3(4) T5-1(2) T5-3(4)
a160 160 200 200
b240 240 280 280
c95160 125 160
[in]T5B-1(2) T5B-3(4)T5-1(2) T5-3(4)
a6.29 6.297.877.87
b9.45 9.45 11.0211.02
c3.74 6.294.926.29
4/4 Emergency On Call Service: Local representative (www.eaton.eu/aftersales)or +49(0) 1805223822 (de, en)
07/16 IL03801009Z
Eaton Industries GmbH, Hein-Moeller-Straße 7-11, 53115 Bonn, Germany
©1999 by EatonIndustries GmbH,www.eaton.eu/documentation All Rights Reserved
07/16 IL03801009Zasim
Printed in Great Britain (08/16)
SVB-SW-P3 DANGER
Only SVB-SW-P3: Lockable in ON position.
Locking the red-yellow switch in ON position is forbidden!
GEFAHR
Nur SVB-SW-P3: In ON-Position abschließbar.
Abschließen in ON-Position bei rot-gelbemSchalterverboten!
DANGER
SVB-SW-P3 uniquement: cadenassable en position ON (fermé).
Cadenassage en position ON (fermé)interdit avec un appareil rouge-jaune !
PELIGRO
Sólo SVB-SW-P3: Bloqueable en positión ON.
Bloquear un mando rojo/amarillo en positión ON está prohibido!
PERICOLO
Solo per SVB-SW-P3: lucchettabile nella posizione ON.
Èvietato lucchettare nella posizione ON l’interruttore con maniglia rosso-giallo!
危危险险
只适用 SVB-SW-P3: 在打开位置可锁住。
ОПАСНОСТЬ
Только SVB-SW-P3: Запираемый в позиции «ON»
При красно-желтом выключателе запрещается запирать в позиции «ON»!
→NOT 1 : 1
d = 4 - 8 mm
(d = 0.16” - 0.31”)
b + d ≦ 47 mm
(b + d ≦ 1.85”)
≦ 3x
D
D
D
OFF
ON
D = 8.5 mm
(D = 0.33”)
d
b
en
de
fr
es
it
zh
ru
[mm]
T5B…/I4 T5…/I5
x142 182
y193 233
[in]
T5B…/I4 T5…/I5
x5.59 7.17
y7.59 9.17
PE
a
b
a
b
c
d
x
y
4 x M5
K-CI-K4
included – enthalten – compris – incluido –
compreso – 包括 –содержится
optional – optional
en option –opcional
opzionale –
по выбору
V-M25/KT-M25
V-M32/KT-M32
T5B.../I4 T5B.../I5
aV-M20
b
KT-M20
V-M20
KT-M20
V-M25/KT-M25
V-M40
V-M50
cK-CI-K5
K-CI-K4d–
–
Fig. 2
25 mm (0.98”)
75 mm (2.95”)
2 x M4
4.1 - 4.5 mm
(0.16 - 0.18”)
Fig. 1
37 mm (1.46”)
14 mm
(0.55”)
12 - 13 mm
(0.47 - 0.51”)
5 - 5.5 mm
(0.2 - 0.22”)
48 mm (1.89”)
26.5 - 29.5 mm
(1.04 - 1.16”)
48 mm (1.89”)
Fig. 3