V / Hz esp: See pump nameplate. Liquid temperature: 4 ~ 50
Storage temperature: -10 ~ Relativa Air Humidity: 95 Max.
+50 .
AFS SERIES PUMPS
Installation diagram
When installing and using this electrical equipment, basic safety
precautions should always be followed, including the following:
IMPORTANT SAFETY INSTRUCTIONS
1) READ AND FOLLOW ALL
INSTRUCTIONS
2 WARNING) To reduce the risk of injury.
do not permit children to use this product
unless they are closely supervised at all
times.
3.WARNING Risk of Electrical Shock.
Connected only to grounding type rece-
ptacle protected by a ground fault circuit
interrupter(GFCI). Contact a qualified
electrician if you cannot verify that the
receptacle is protected by GFCI.
4 CAUTION Do not bury cord. Locate )
cord to minimize abuse from lawnmowers,
hedge trimmers, and other equipment.
5 CAUTION ) In case the running
parts will injure people, don't make
the electric pump running before then
pipeline have been connected.
6 WARNING) To reduce the risk of
electrical shock, replace damaged
cord immediately.
7 WARNING) To reduce the risk of
electrical shock, do not use extension
cord to connect unit electric supply;
provide a properly located outlet.
8 CAUTION )
Jetpump for jetted bathtubs,
spapools, swimmingpools, massage
stations, cleaning system.
9)Do not install within an outer encl-
osure or beneath the skirt of a hot tub
unless so marked.
10) This appliance is not intended for use
by young children or infirm persons unless
they have been adequately supervised by
a responsible person to ensure that they
can use the appliance safely.
11)Young children should be supervi-
sed to ensure that they do not play with
the appliance.
12 SAVE THESE INSTRUCTIONS)
SWIMMING TRAINING PUMP
INSTRUCTION MANUAL
1) General
These instructions are for correct installation, and optimum performance of the Bath
pumps, so they should be read carefully. These are single-stage centrifugal pumps
designed to operate with compact hydromassage equipment, They are equipped with
a total-emptying system to prevent the discharge of residual liquid in each stopping.
These units are designed to operate with clean water at a maximum water temperature
of 50°C. Built of top quality materials, they are subjected to strict hydraulic and electrical
controls and are carefully verified. Correct installation is ensured by following these
instructions and those of the wiring diagram; otherwise, over loads may be produced in
the motor. We decline responsibility for any damage caused by not following these
instructions.
180
280
430
245
215
E
77
319
163
95
E
Model Qmax
3
(m / h)
Hmax
(m)
90 17.5
AFS40 78 13
E
3
G2 /
4
or
4FBT
Power
P1 (kW)
4.0
3.0
1-44-4
EM PU16 0227 62
AFS55
Pump parts for AFS