8.5 Canada
E6 Canada Explosionproof, Dust Ignition-proof, Division 2
Certificate: 1143113
Standards: CAN/CSA C22.2 No. 0-10, CSA Std C22.2 No. 25-1966,
CSA Std C22.2 No. 30-M1986, CSA C22.2 No. 94.2-07,
CSA Std C22.2 No. 213-M1987, CAN/CSA C22.2 60079-11:14,
CAN/CSA-C22.2 No. 61010-1-12, ANSI/ISA 12.27.01-2003,
CSA Std C22.2 No. 60529:05 (R2010)
Markings: Explosionproof Class I, Division 1, Groups B, C, D; Dust-Ignitionproof Class II,
Division 1, Groups E, F, G; Class III; suitable for Class I, Division 2, Groups A, B,
C, D; Type 4X
I6 Canada Intrinsically Safe
Certificate: 1143113
Standards: CAN/CSA C22.2 No. 0-10, CSA Std C22.2 No. 25-1966,
CSA Std C22.2 No. 30-M1986, CSA C22.2 No. 94.2-07,
CSA Std C22.2 No. 213-M1987, CAN/CSA C22.2 60079-11:14,
CAN/CSA-C22.2 No. 61010-1-12, ANSI/ISA 12.27.01-2003,
CSA Std C22.2 No. 60529:05 (R2010)
Markings: Intrinsically Safe Class I, Division 1; Groups A, B, C, D; suitable for Class 1,
Zone 0, IIC, T3C, Ta= 70 °C; when connected per Rosemount drawing
03151-1207; Type 4X
IF Canada FISCO Intrinsically Safe
Certificate: 1143113
Standards: CAN/CSA C22.2 No. 0-10, CSA Std C22.2 No. 25-1966,
CSA Std C22.2 No. 30-M1986, CSA C22.2 No. 94.2-07,
CSA Std C22.2 No. 213-M1987, CAN/CSA C22.2 60079-11:14,
CAN/CSA-C22.2 No. 61010-1-12, ANSI/ISA 12.27.01-2003,
CSA Std C22.2 No. 60529:05 (R2010)
Markings: FISCO Intrinsically Safe Class I, Division 1; Groups A, B, C, D; suitable for
Class I, Zone 0; T3C, Ta= 70 °C; when installed per Rosemount drawing
03151-1207; Type 4X
8.6 Europe
E1 ATEX Flameproof
Certificate: KEMA 00ATEX2143X
Standards: EN 60079-0:2012, EN 60079-1:2007, EN 60079-26:2007
(3051SFx models with RTD are certified to EN 60079-0:2006)
Markings: II 1/2 G Ex d IIC T6…T4 Ga/Gb, T6(-60 °C ≤ Ta≤+70 °C),
T5/T4 (-60 °C ≤ Ta≤+80 °C)
Special Conditions for Safe Use (X):
1. The device contains a thin wall diaphragm. Installation, maintenance and use shall take
into account the environmental conditions to which the diaphragm will be subjected.
The manufacturer’s instructions for installation and maintenance shall be followed in
detail to assure safety during its expected lifetime.
Temperature class Process temperature
T6 -60 °C to +70 °C
T5 -60 °C to +80 °C
T4 -60 °C to +120 °C