Dimensions:
5/16" (8mm)
2" (50mm)
2" (50mm)
2" (50mm)
23/8" (60mm)
¤¤¤¤¤¤¤¤¤
¤¤¤¤¤¤¤¤¤
Reflective
Photoelectric
Sensor
E-931-S35RRQ
Range: 35ft. (11m)
Sensor
Reflector
Sensor
ENFORCER®
Caution:
ENFORCER
®
15/8"
(40mm)
13/16"
(30mm)
25/8" (66mm)
25/16" (58mm)
5/8"
(15.1mm)
13/16"
(20mm)
3/16"
(5mm)
2-Ø4.5 thru hole Ø6 cable 2M
Includes:
13/16" (20mm)
•This sensor was not designed to prevent bodily injury
or loss of life.
•This sensor was not designed for use in
environments where there is the possibility of
explosive gasses present.
INSTALLATION MANUAL
Features: Typical Applications:
••
••
•Weatherproof (IP 66) design
for indoor/outdoor use.
••
••
•Dark ON operation.
••
••
•Pre-wired 6-foot cord.
••
••
•Adjustable sensing distance.
••
••
•NO/NC/COM relay output.
••
••
•Compact size.
•Safety sensor for garage doors
or outdoor gates.
•Overhead door security sensor.
•Industrial automation
--
Detect small objects on a
manufacturing line.
•Entry detection for storefronts.
•Assist in measuring parking distance.
•Alarm sensor.
•Use of this sensor in certain security applications
may be regulated by local laws or codes.
SECO-LARM is not responsible for compliance with
such laws or codes.
••
••
•Reflector (E-931ACC-R)
••
••
•Transmitter/Receiver
(E-931-S35RRQ)
••
••
•Sensor mounting
bracket
(E-931ACC-BLS1)
••
••
•Reflector mounting
bracket
(E-931ACC-BLR1)
••
••
•Mounting hardware also
included.
2
Wiring:
Mounting the Sensor:
W
e
m
e
c
l
o
Accessories:
Gate
Gate
Gate
Gate
¤¤¤¤¤¤¤¤¤¤¤
¤¤¤¤¤¤¤¤¤¤¤
Garage
door
¤¤¤¤¤¤¤¤¤¤
¤¤¤¤¤¤¤¤¤¤ ¤¤¤¤¤
¤¤¤¤¤
¤¤¤¤¤¤¤¤
¤¤¤¤¤¤¤¤
¤¤¤¤¤¤¤¤
¤¤¤¤¤¤¤¤
Sample Installations:
Gate Main
entrance
door
Store front door
¤¤¤¤¤¤¤¤¤¤¤¤¤¤¤¤
¤¤¤¤¤¤¤¤¤¤¤¤¤¤¤¤
Black (N.O.)
Gray (N.C.)
White (COM)
Relay output
Multi-voltage
circuit
Brown
Blue ]24-240VAC or
12-240VDC,
polarity not
important
Connection (5 wires)
Note:
1. Can be connected to AC or DC voltage.
2. Maximum cable extension length is
325 feet (100 meters).
Vehicle detection Factory assembly
line
E-931ACC-RC1Q
E-931ACC-R
E-931ACC-HR1Q
3
Mounting the Reflector:
Installation and Adjustment:
Sample Fixed
Mounting:
Samples For Horizontally Adjusting
Mounting:
Samples For Vertically Adjusting Mounting:
Yellow
LED
Sensitivity
Adjuster
Red LED
LED Functions:
• Red LED -- When ON, it indicates the sensor is triggered.
• Yellow LED -- When ON, it indicates that the sensor is
properly aligned with the reflector, and the sensor is not
triggered.
Sensitivity Adjustment Functions:
• Min. Setting -- The infrared signal emitted by the sensor is at
its minimum or weakest. This means the sensor can be
easily triggered by small obstructing objects.
• Max. Setting -- The infrared signal emitted by the sensor is
at its maximum or strongest. This means the sensor cannot
be easily triggered by small obstructing objects.
Installation:
1. Mount the reflector and the sensor so they face each other.
2. Connect power to the sensor. Typically the red LED will turn
ON indicating that the sensor and reflector are not yet
properly aligned. If the yellow LED is ON (red LED OFF), it
indicates that the sensor and reflector are aligned (although
it still may be necessary to slightly adjust the alignment).
3. Turn the sensitivity knob to Max.
4. To find the correct alignment, slowly adjust the angles of the
sensor (and/or reflector) up and down and right and left.
NOTE 1: Correct alignment is reached when the red LED
turns OFF and the yellow LED turns ON.
NOTE 2: If both LEDs are OFF, the sensor is at the edge of
sensing the signal, and may not work properly.
Adjusting Sensitivity:
After the sensor and the reflector have been properly installed,
the next step is to adjust the sensor sensitivity.
1. Turn the sensitivity knob counterclockwise to “Min.”
2. Slowly turn the sensitivity knob clockwise until the yellow
LED turns ON. Mark this position “A”.
NOTE: If the yellow LED is ON when the sensitivity knob
has been adjusted to “Min.”, then position “A” will be at
“Min.”
3. Put the object to be detected between the sensor and
reflector (in about the place where the object would
normally be detected by the sensor). The yellow LED
should turn OFF (red LED is ON)
4. Slowly turn the sensitivity knob to clockwise until the yellow
LED turns ON. Mark this position “B”.
NOTE: If the yellow LED does not turn ON even when the
sensitivity knob has been adjusted to “Max.” then position
“B” will be at “Max.”.
5. Turn the sensitivity knob counterclockwise until it is set at
the center (midpoint) between points “A” and “B”. This will
be the suggested sensitivity setting.
Testing:
1. Power up the sensor. The yellow LED should be ON; the
red LED should be OFF.
2. Pass the object to be detected between the sensor and
reflector. The red LED should turn ON and the yellow LED
should turn OFF. This indicates that the object has been
detected.
NOTE: If a shiny object, such as a chrome-plated or
stainless-steel item, or something with reflective tape, will
be passing between the sensor and reflector, the sensor
may not be able to detect it. In this case, it may be
necessary to turn the sensitivity knob counterclockwise
until the desired sensitivity setting is obtained.
Specifications:
Troubleshooting:
NIRmUd.PMD
E-931-S35RRQ
Reflective Photoelectric Sensor
0.5' to 35' (0.1 - 11 m)
12-240 VDC or 24-240 VAC
Stand by Active
12VDC 20mA 40mA
24VDC 10mA 20mA
10ms (max.)
IR LED
Yellow LED (Alignment), Red LED (trigger)
N.O./N.C./Common
1A @ 50VAC
IP 66 Weatherproof
-40~1310F (-200~550C)
Included
Model Number
Type
Sensing Range
Voltage Supply
Current Drain
Response Time
Light Source
LEDs
Trigger Output
Switching Capacity
Enclosure
Ambient Temperature
Mounting Brackets for Sensor and Reflector
Yellow LED does not turn on. 1) Dirty sensor and/or reflector.
2) Reflector and/or sensor is
misaligned.
1) Clean the sensor and reflector with
a damp (not wet) cloth.
2) Adjust the reflector and/or sensor
for proper alignment.
Red LED lights when object
is detected, but no output.
No continuity between sensor and
alarm device.
Check cable from sensor to alarm
device. Test sensor.
Sensor does not detect the
object.
1) Sensor sensitivity is not properly set.
2) Object may have a reflective surface
which confuses sensor.
Change the angle of the sensor or
readjust the sensitivity setting.
Trouble Remedy(s)Possible Origin(s)
WARRANTY
This SECO-LARM product is warranted against defects in material and workmanship while used in normal
service for a period of one (1) year from the date of sale to the original consumer customer. SECO-LARM’s obligation is
limited to the repair or replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM.
This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect,
repair, or alteration, improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines
that such equipment is not operating properly as a result of causes other than defects in material and workmanship.
The sole obligation of SECO-LARM, and the purchaser’s exclusive remedy, shall be limited to replacement or repair only, at
SECO-LARM’s option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential
personal or property damages of any kind to the purchaser or anyone else.
SECO-LARM®U.S.A., Inc.
16842 Millikan Avenue, Irvine, CA 92606
Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326
Website: www.seco-larm.com
E-mail: sales
@
seco-larm.com
NOTICE: The information and specifications printed in this manual are current at the time of publication. However, the
SECO-LARM policy is one of continual development and improvement. For this reason, SECO-LARM reserves the right
to change specifications without notice. SECO-LARM is also not responsible for misprints or typographical errors.
Copyright © 2013 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in whole
or in part, without the written permission of SECO-LARM.

Other ENFORCER Accessories manuals

ENFORCER Enforcer SD-927PKC-NEQ User manual

ENFORCER

ENFORCER Enforcer SD-927PKC-NEQ User manual

ENFORCER E-931-S35RRQ User manual

ENFORCER

ENFORCER E-931-S35RRQ User manual

ENFORCER E-9622-4B25 User manual

ENFORCER

ENFORCER E-9622-4B25 User manual

ENFORCER Seco-Larm SLI E-936-S45RRGQ User manual

ENFORCER

ENFORCER Seco-Larm SLI E-936-S45RRGQ User manual

ENFORCER No Touch SD-927PKC-NEQ User manual

ENFORCER

ENFORCER No Touch SD-927PKC-NEQ User manual

ENFORCER CS-PD115-PAQ User manual

ENFORCER

ENFORCER CS-PD115-PAQ User manual

ENFORCER SD-9 63 Series User manual

ENFORCER

ENFORCER SD-9 63 Series User manual

ENFORCER E-931-S50RRQ User manual

ENFORCER

ENFORCER E-931-S50RRQ User manual

ENFORCER SLI SECO-LARM SD-9163-KSQ User manual

ENFORCER

ENFORCER SLI SECO-LARM SD-9163-KSQ User manual

ENFORCER E-931-S45RRQ User manual

ENFORCER

ENFORCER E-931-S45RRQ User manual

ENFORCER E-931-S50RRGQ User manual

ENFORCER

ENFORCER E-931-S50RRGQ User manual

ENFORCER E-932-D33TBQ User manual

ENFORCER

ENFORCER E-932-D33TBQ User manual

ENFORCER Enforcer SD-927PKC-NEQ User manual

ENFORCER

ENFORCER Enforcer SD-927PKC-NEQ User manual

ENFORCER SECO-LARM SD-9773-KNEVQ User manual

ENFORCER

ENFORCER SECO-LARM SD-9773-KNEVQ User manual

ENFORCER E-931-S50RRLQ User manual

ENFORCER

ENFORCER E-931-S50RRLQ User manual

ENFORCER ECO-LARM RM-R100-TLQ User manual

ENFORCER

ENFORCER ECO-LARM RM-R100-TLQ User manual

ENFORCER ENFORCER EVT-RBP-GNCQ* User manual

ENFORCER

ENFORCER ENFORCER EVT-RBP-GNCQ* User manual

ENFORCER E-931CS22RRCQ User manual

ENFORCER

ENFORCER E-931CS22RRCQ User manual

ENFORCER E-936-S35RRGQ User manual

ENFORCER

ENFORCER E-936-S35RRGQ User manual

Popular Accessories manuals by other brands

AECO SMC-12 NO SS BC HF AGD1 Series operating instructions

AECO

AECO SMC-12 NO SS BC HF AGD1 Series operating instructions

Vega VEGAPULS 61 Quick setup guide

Vega

Vega VEGAPULS 61 Quick setup guide

Satel S-4 quick start guide

Satel

Satel S-4 quick start guide

ITI Learn Mode 60-742 installation instructions

ITI

ITI Learn Mode 60-742 installation instructions

Tascam FW-1884 Service manual

Tascam

Tascam FW-1884 Service manual

Carrier Smart Sensor installation instructions

Carrier

Carrier Smart Sensor installation instructions

JBL Cooler 100 Important instructions

JBL

JBL Cooler 100 Important instructions

CYBEX PARASOL instructions

CYBEX

CYBEX PARASOL instructions

Hytronik HEC9025/I Installation and instruction manual

Hytronik

Hytronik HEC9025/I Installation and instruction manual

WG SPLIT Series Quick start installation guide

WG

WG SPLIT Series Quick start installation guide

Edirol EDIROL FA-101 install guide

Edirol

Edirol EDIROL FA-101 install guide

Viessmann KOB 8110-1 Spec sheet

Viessmann

Viessmann KOB 8110-1 Spec sheet

Manitowoc K00044 installation instructions

Manitowoc

Manitowoc K00044 installation instructions

ABB SmarTac Applications manual

ABB

ABB SmarTac Applications manual

Viking DBCV3082 installation instructions

Viking

Viking DBCV3082 installation instructions

Gembird PB20-02 user manual

Gembird

Gembird PB20-02 user manual

CKD WKF2 Series manual

CKD

CKD WKF2 Series manual

KSB KSB Leakage Sensor Installation & operating manual

KSB

KSB KSB Leakage Sensor Installation & operating manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.