Exide WSC 720 User manual

DIAGNOSTIC POWER SUPPLY
WSC 720
1
USER GUIDE
12 V/24 V Lead acid batteries 40-500 Ah
GB

2
THANK YOU FOR CHOOSING THIS
CHARGER FROM EXIDE TECHNOLOGIES
Your WSC720 is a quality product from Exide Technologies.
WSC720 is designed to be user friendly, and contains the latest in
charging technology that will optimize battery performance and
service life.
WSC720 will ensure fully recharged batteries and also act as a
power supply for diagnosis during car service.
Read the safety instructions and user guide carefully. If you follow
the instructions, you will benefit from a high-performance charger
and power supply that will give excellent service for many years to
come. Discarded packaging can be recycled.
For more information about Exide and our products, please visit:
www.exide.nu (Swedish)
Best regards
Exide Technologies

3
GETTING STARTED
1. Connect the charger’s red cable clamp to the battery’s positive
terminal post (+), and the black cable clamp to the battery’s
negative terminal post (-).
2. Connect the charger’s mains plug to a grounded power socket.
3. Select the correct function by pressing the “Mode”-button.
Charging:
•Choosevoltage:12Vor24V
•Choosebatterytechnology:StandardorAGM/Gel
Power Supply:
•13,7VPowerSupply
OBS! This function is only for 12 V-system
4. When the LED for the select mode is green, the battery is fully
charged. Remove the mains plug and the cable clamps.
5. If wrong voltage, or polarity, is chosen, the charger will not start.

4
INFORMATION
• WSC720isapowerfulchargerforservicestations.
• WSC720canbeusedfor:
1.Asabatterychargerfor12Vand24Vbatteries
2.Tomaintainvoltagein12Vand24Vsystems
3.AsPowerSupplyfor12Vsystem
• Inchargemodes(12Vand24V)WSC720willinitiallychargethe
battery, and then, with a constant current charging (float charge)
as long as it is connected, maintain full charge.
• Inthechargemodes(12Vand24V),WSC720willalsomaintain
systemvoltage,functioningasaDiagnosticPowerSupply,
givingupto70A.
• In”13,7VPowerSupply”WSC720willactasaPowerSupplyfor
12Vequipment.Thismodewillgiveacurrentupto70Ausefulas:
- PowerSupplyatreplacementof12Vbatteries
- PowerSupplyin12Vsystems
- PowerSupplyfordiagnosis
• WSC720isequippedwithatemperaturecompensator,which
will give best possible charging independently of temperature.

5
WSC720 USER GUIDE
1. Readthesafetynotesandadheretothestatedprecautions.
2. Connect the red cable clamp to the battery’s positive terminal
post (+), and the black cable clamp. The position of the cables,
seepage11.
3.Connectmainsplugtoanearthedpowersocket.
4.Ifthecablesareincorrectlyconnected,orifwrongsystemvolta-
ge(12Vor24V)ischosen,theredLEDwillilluminatetoindicate
a fault. If so, check the connection and adjust accordingly.
5. WSC720 will start charging in the mode last used. If necessary,
press the ”Mode” button repeatedly until desired mode is selected.
Mode:
•For12Vbatteries:Charging
ofStandardorAGM/Gel
see page 6*
•For24Vbatteries:Charging
ofStandardorAGM/Gel
see page 6*
•For12Vsystems:Voltageand
PowerSupply,13.7V
Indication:
•IfWSC720iscorrectly
connected, the yellow LED
flashesforaround4seconds
when the LED will stop
flashing and will change to a
constant yellow.
•Inthe“13.7VSupply”mode,
the green LED lights while the
function is connected.
Continues on next page.

6
6. The LED will show a constant yellow until the charge is
complete, then the LED changes from yellow to green.
7. When charging is complete first the mains plug should be
removed and then the cable clamps.
8. If the cables are left in place there will be a continual
maintenanceofchargeat13,7V,otherwisestopthecharging
according to the instruction.
Facts about Batteries:
* BatteriesareeitherAGM/GELorStandardtype.
- AGM/GELarevalve-regulatedbatteries,wheretheelectrolyte
(the acid) is absorbed or is in gel form, and are often clearly
markedAGMorGEL.
- Other batteries are standard batteries.

7
SAFETY INSTRUCTIONS
• WSC720hasbeenconstructedtocharge12Vleadacid
batteriesortoactasapowersupplyfor12Vequipment.
Do not use the charger for other purposes.
• WSC720isconstructedforindoorpurposeandmustbe
protected from moisture.
• DonotuseWSC720ifitscables,terminalclampsorcasing
are damaged.
• Batteriesemitexplosivegaseswhiletheyarecharging.Itis
therefore important to ensure good ventilation and avoid sparks
and naked flames in the vicinity of the battery.
• Becarefulandavoidmetalliccontactbetweentheclamps.
• Useprotectiveeyewearwhenworkingwithbatteries.
• Batteryacid(electrolyte)iscorrosive.Ifeyesorskincomeinto
contact with the acid, rinse immediately with copious amounts
of water, and contact a doctor immediately.
• Neverchargeafrozenbattery.
• Terminatethechargingifthebatterygetshot.
• NeverpositionWSC720abovethebatteryduringcharging.
• DonotcoverWSC720.
• Notethatinthe“13.7VSupply”modethechargerprovidesa
constantoutputvoltageof13.7Vthatincertaincircumstances
may cause sparking.
• WSC720isprotectedagainstoverheating.Iftheambient
temperature is too high, the charging current is reduced.
• Duringthecharge,thechargermayintermittentlyprovidea
15.5Vchargevoltage.Ensurethatnoequipmentwhichmaybe
damaged by this voltage level is connected to the battery during
charging.

8
FUNCTIONS:
• WSC720mustbeconnectedtothebatteryasdescribedinthe
UserGuide.Afteritisconnected,itwillchargethebatteryand
maintain it fully charged with constant voltage charging (float
charge) as long as it is connected to the mains power.
• Don’tkeepWSC720connectedtothebatterywithoutmains
connected. This will in the long term discharge the battery.
• WSC720isfullyautomaticandisprogrammedforadvanced
chargingoflead-acidbatteriesbetween40and500Ah.
• Ifthe24Vmodeisselected,thebatteryvoltagemustbehigher
than15.8V.Ifnot,theredLEDwillindicateafault.
• Securityfunctionswillreduceovercharging,byterminatingthe
charge,especiallyifthebatteriesarelargerthan500Ah.
• WSC720canbeusedasaPowerSupplybypressingthe
”Mode”buttonto13.7VPowerSupply.InthismodeWSC720
willprovideavoltageof13.7Vandmax.70A.
• ”13.7VPowerSupplyistobeusedforPowerSupplyin12V
electrical systems and for continuous charging, float charge, of
12Vbatteries.
• Formaintainingvoltagein24Vsystems,Mode“24Vcharging”
shall be used.
• WSC720isequippedwithtemperaturecompensation.The
thermal sensor is integrated in the negative, black, terminal
clamp.
• Thankstoourtemperaturecompensation,thecommon
problems involved in insufficient charging in cold weather and
overcharging at high temperatures are eliminated.
• Thechargingcurveconsistsoffivestepsthatareadaptedto
battery technology.
• Inordertominimizetheriskofovercharginganincorrecttype
of battery, WSC720 is equipped with a cut-out function that
interrupts the process after 7 h and the fault is shown by the
LEDshiningaconstantred.NOTE:Thisalarmcanbetriggered
when charging batteries that have capacities exceeding
the recommended battery size, or in connection with other
Continues on next page.

9
equipment drawing current (parallel loads) being connected to
the battery during charging.
• Batterieswillbedamagedwhenchargedathightemperatures.
For this reason, WSC720 features a safety function that
terminates charging when the temperature is too high, approx.
50°C. This is shown by the LED shining a constant red.
FAULT INDICATIONS AND TROUBLE SHOOTING
Fault: The red LED lights when the charger cables are connected
to the battery terminals.
Probable cause 1: If the cable clamps are incorrectly connected
to the battery, the polarity reversal protection will be activated and
charging will not start.
Action: Check that the charger is connected using the
correct polarity.
Probable cause 2:Wrongvoltagemodeforcharging.12Vfora
24Vsystem.
Action: AdjustthevoltageMode.
Probable cause 3:Wrongvoltagemodeforcharging.24Vfora
12Vsystem.
Action:AdjustthevoltageMode.
Probable cause 4:Avoltagebelow15.8Vina24Velectrical
system.
Action:PleasetrytouseMode“13.7VPowerSupply”forashort
while(max.10minutes)oneachofthebatteriesinthe24V-system.
In order to avoid unbalanced batteries, it is highly important that
all batteries are charged exactly the same time.
1.
Continues on next page.

10
Fault: Charging does not start, i.e. the lamp continues to shine,
and the yellow LED does not change to the steady yellow light.
Probable cause: The battery voltage is too low, less than 7 V, to
start the charger. This may be because the battery is worn or faulty
or has been completely discharged.
Action: Try to connect the 13.7 V Supply mode for a short while
(max. 10 min). Restart charging. This usually works if the battery is
really heavily discharged, but otherwise in good condition. Please
be careful with the connection of the terminal clamps.
Fault: Charging started normally, but did not complete. The red
LED illuminates and charging is terminated.
Probable cause 1: Defective battery. The battery has a fault that
does not permit it to be charged, e.g. a short circuit.
Action: Replace the battery.
Probable cause 2:Parallelload.Ifapieceofequipmentthatdrains
current is connected to the battery, there is a risk that the capacity
of the charger is not sufficient to charge the battery within the time
constraints that are built into the charger for safety reasons.
Action: If possible, disconnect the parallel load and repeat
charging, or purchase a larger charger suitable to cater for both
the needs of the charge and parallel load drain.
Probable cause 3: Battery is too large. The battery is larger than
the recommended size for the charger, which means that the
charge could not be completed within the time constraints that are
built into the battery for safety reasons.
Action: Repeat charging.
Probable cause 4: The high temperature cut-out that monitors the
battery temperature has been triggered. The reason for the high
temperature could be that the battery has an internal fault, or that
the ambient temperature is high.
Action: If charging is carried out at room temperature, the high
temperature is probably caused by a battery fault or wear. The
battery should be replaced. If charging is taking place at a high
ambient temperature, charging may be resumed when the battery
has cooled to room temperature.
2.
3.
Continues on next page.

11
MAINTENANCE / ACCESSORIES
• The charger is fully maintenance-free.
• Opening the charger will invalidate the guarantee.
• Don’t use WSC720 if the mains cable is damaged. Replace the
cable. Do not use the charger if its cables, terminal clamps or
casing are damaged.
• The plastic parts of the clamps are exchangeable. NB! Make
sure that the red clamp is attached to the positive cable and
that the black clamp to the negative.
• The case may be cleaned using a soft, damp cloth and a mild
detergent. The charger must be disconnected from the mains
when being cleaned.
The product is not suitable for use by persons who lack knowledge
or experience, unless they are supervised by, or have received
information about how to use the product from a person who is
responsible for their safety.
Do not allow children to play with any part of the product.
PoWEr
nEG.
CaBlE
Pos. CaBlE
ContaCt for tHErMal
sEnsor rJ45
not aCtiVatEd

12
MODEL EXIDE WSC720
WSC720 is a primary-switched computer-controlled charger
and a Power Supply
Input voltage 190-255VAC,45-400Hz
Between90-190VACreduced
power.90VACgives50%power.
Back current ≤2,5mA/12V,≤5mA/24V
Charging voltage 12 V FV 13,7-15,5VDCat25ºC
Charging voltage 24 V FV 27,4–31,0VDCat25ºC
Charging voltage 12 V VR 13,7–14,4VDCat25ºC
Charging voltage 24 V VR 27,4–28,8VDCat25ºC
Charging voltage Supply 13,7VDC
Charging current 12 V Max.70A
Charging current 24 V Max.60A
Ambient temperature -25/+50ºC
Cooling Fan
Type of charge IU1U2U3U4
Afullyautomatictechnologyadapted
chargingprofileinfivesteps,alt.13,7V
PowerSupply/floatcharge.
Lead acid battery types StandardandAGM/Gel
Battery capacity 40-500Ah
Dimensions (LxWxH) 258x136x89mm
International Protection ratingIP20,(IP21forhorizontal
placement)
Protection class 1,earthed
Weight 2,3kgwithoutcablesand
4,5kgwithcables

13
CE ManufaCturEr’s dEClaration
Product: Battery charger EXIDE WSC720
Manufacturer:
EXIDE Technologies, Bultgatan 40A, Kungälv, Sweden and
Primepower AB, Idavägen 11, Växjö, Sweden
The manufacturer guarantees that the unit complies with the
relevant standards. Tested and approved by Intertek Semko.
LVD-Standard
EN 60335-2-29:2004 + A11:97 (IEC335-2-29:2002 modified)
EN 60335-1:2002 + A11:2004#A1:2004-A12:2006+A2006
EN50366:2003 + A1:2006
EMC-Standard
EN 61000-6-2
EN 61000-6-3
EN 61000-3-2
EN 61000-3-3

14
Warranty
We guarantee that this product is constructed to the highest
quality specifications, and manufactured to the best industrial
standard. If the product should prove to be faulty or has damage
that can be related to manufacture or distribution, the mandatory
guarantee rights apply.
The guarantee (NL 2010, 2 years) will no longer be valid if
the charger has not been handled correctly, or opened or
repaired by any other than Exide Technologies or its authorized
representatives.
Exide Technologies is not responsible for other costs than those
stated above, i.e. no potential consequential costs. Nor is Exide
Technologies liable under any other warranty than this one.
Table of contents
Other Exide Batteries Charger manuals
Popular Batteries Charger manuals by other brands

Lenmar
Lenmar Lenmar OmniSource BCR261 owner's manual

Energizer
Energizer PowerKeep PRO manual

ULTIMATE SPEED
ULTIMATE SPEED ULG 17 A1 Operation and safety notes translation of the original instructions

Phihong
Phihong DS Series User's manual & installation instructions

Bosch
Bosch Surly BCS210 owner's manual

IBM