Installation - Other Terrarium Models
Refer to your terrarium’s instruction manual for instructions on how to
install equipment, wiring and tubing inside the terrarium.
1.
Mountthenozzlesinpositionontheglassportionofthe
terrarium’s sidepanelswiththesuctioncups.Makesurethat
theglassareaiscleanandfreeofanydirtordepositsbefore
mounting the nozzles. For the best results, mount the nozzles
ascloseaspossibletothefrontopeningwindowsandthetop
screen.
2. Direct the nozzle positions inside the terrarium so that the spray
streamwillavoidsprayingontheterrarium’sfrontandside
panels when inoperation.
3. Use the additional suction cups to neatly guide the tubing along
thesidepanelstotheinletlocationofyourterrarium.
4.
ConnectthetubingfromthenozzlestotheY-connectorby
pressingthetubingfirmlyintooneoftheside-by-sideholesas
faraspossible.Connectboth nozzles.
5. Connect the tubing to the remaining hole of the Y-connector by
pressingitfirmlyinsideasfaraspossible.
6. Place the Monsoon RS400 unit on a hard, stable, level surface.
7. Connect the tubing coming from the Y-connector to the top of
theunitbypressing thetubingfirmlyintotheopeningasfar
aspossible.
8.
Makesurethatthefilterisproperlyconnectedtothespigoton
the underside of the control unit and placed inside the reservoir.
9.
EnsurethatthetopoftheMonsoonRS400unitfitstightlyon
operate for 60 seconds.
•
TheExoTerra
®
MonsoonRS400shouldbesetaccordingto
theneedsoftheanimalsandtothesizeoftheterrarium.Be
carefulnottooperatetheunittoofrequentlyortoolongto
avoidoverflowingtheterrarium!Theunitshouldbesetsothat
wateraddedtotheterrariumfromthefirstoperatingcycleis
allowed to evaporate before the next operating cycle begins,
oratleastmakesurethattheexcesswatercanbedrainedout
of the terrarium.
•
Aftertheunithasbeensetandthecyclebuttonhasbeen
pressed on (blue cycle LED is illuminated), the unit immediately
startsit’sfirstcycle.Thenextcyclewillbegindependingon
hourlysettingofthefirstdial.Iftheunitisswitchedoff,the
cyclewillstartagainafterthecyclebuttonhasbeenpressed.In
thecase ofapowerfailure,theunitwill automatically resume
incyclemode.Thefirstcyclestartsassoonasthepower
comes backon.
•
Whenthereservoirisempty,itisadvisabletorefillthereservoir
immediatelyortoswitchofftheunit.Thepumphasabuiltin
safety cut-offthatwill switch offthepump(nottheunit)when
overheated.Whenthepumpcoolsdown,itwillautomatically
switchonagain.Thisisasafetyfeature,andoneshouldnot
relyonthethermalcut-off.
Adding additional Nozzes to the system
The Exo Terra
®
Monsoon RS400 can be operated with up to 6
nozzles. Please note that every additional nozzle will result in less
performance from each nozzle installed. To connect additional
8
top of thereservoir.
nozzles, an extra nozzle (PT2501) and a Y-connector (PT2498) is
10.
Open thesmall lid ontopoftheunit, andfill the reservoir with
de-mineralized/distilled wateruptoamaximumof2,5cm(1”)
from the top rim of the transparent reservoir. (Using regular tap
water will cause clogging of the nozzles by mineral deposits!)
11.
Closethelidandconnectthepowersupplyjacktotheback
oftheunit.
12.
Makesuretheunitisinitsfinaloperatinglocation,standing
level on a hard surface.
13.
Plugthepoweradaptorintothewallsocket,yourExoTerra
®
Monsoon RS400 High-pressure Misting system is now ready
to use.
Operating instructions
•
O- The Exo Terra
®
Monsoon RS400 is switched off - No blue
LED light is visible
•
On- The Exo Terra
®
Monsoon RS400 is switched on - the
leftblueLEDlightisilluminatedandtheunitwilloperate
continuously.
•
Cycle - The Exo Terra
®
Monsoon RS400 is in cycle mode - the
rightblueLEDlightisilluminatedandtheunitwilloperate
accordingtotheprogramsettingofthecycle andduration
controls.
•
Theleft dialistosetthe“ON” cycle (in hours) oftheunit.For
example,whenthedialisseton4,theunitwilloperateevery
4 hours.
•
The right dial sets the duration of each operating cycle (in
seconds).Forexample,whenthedialissetto60,theunitwill
needed(soldseparately).Simplycutthetubingwhereconvenient,
preferablyascloseaspossibletothefirstY-connector.Makesure
thenozzlecaneasilybemountedinitsintendedlocationwithout
stretchingthetubing.Connectthetubingcomingfrom theunitto
thesingleholeoftheY-connectorandtheotherendofthetubingto
the double hole. Connect the tubing from the additional nozzle to the
otherholeoftheY-connector.
Please note that additional nozzles also can be mounted in different
terrariums.
Remote Control (Optional)
Aremotecontrol(PT2496)issoldseparatelytooperatetheunit.It
also hasthe same three operation buttons (Off, On, Cycle), but the
cycleanddurationstillhavetobesetontheunititself.Theremote
control is ideal for launching additional spray sessions without
disturbingtheanimalsbyhavingtogotoneartotheterrarium.
Maintenance
Itisadvisabletoplacetheunitinadarklocationorotherwise
shieldedfromlighttopreventthegrowthofalgaeinthereservoir.
Shouldalgaeform,justwipetheinsideofthereservoirwitha
dampcloth.DoNOTusedetergentorsolventsasitmightharm
yourterrariumanimals! Makesuretodiscard anydirtywateror
water containing debris or particles. Only use de-mineralised/
distilled water or debris-free and clean rainwater! Replace the filter
regularly,atleasteverysixmonthsdependingontheusageand
water quality. If the nozzles are clogged or if they spray irregularly,
place the nozzles overnight in a 50/50 water/vinegar solution. Rinse