FEMA ELECTRÓNICA . Series M . M40-A
2
1. Panel meter M40-A
AC voltage and AC current meter 96x48mm (1/8 DIN) for panel mount
Panel meter 96 x48 mm (1/8 DIN) for AC voltage and AC current sig-
nals. Reading with 4 digits scalable to ±9999 with selectable decimal
point posion. Measure in True RMS. Measure category CAT-II and
CAT-III. AC voltage measure up to 600Vac, and AC current measure up
to 5Aac. Signal measure coupling mode selectable in ‘AC’ or ‘AC+DC’.
Opons for output and control with 1, 2 and 3 relays, isolated analog
outputs, communicaons in Modbus RTU, RS-485 ASCII and RS-232.
Special opons with 4 and 6 relay outputs.
Independent alarms congurable as maximum or minimum, with 1
or 2 setpoints per alarm, hysteresis, independent acvaon and de-
acvaon delays and control for inverted relay.
Front protecon IP54 with oponal IP65. Connecons by plug-in
screw terminals. For industrial applicaons.
• ‘Fast access’ menu to selected funcons, accessible with key UP (5)
(see secon 1.12.5)
• ‘Field correcon’ for fast and easy on-the-eld correcon of signal
osets (see secon 1.12.2)
• ‘On power up’ for system protecon on rst ‘cold’ start-up (see
secon 1.12.7)
• Measure technique in ‘True RMS’
• Measure coupling ‘AC’ or ‘AC+DC’ (see secon 1.9)
• ‘Peak & hold’ for test-break applicaons (see secon 1.12.4)
Mulple display lters, memory for maximum and minimum reading,
password protecon, 5 brightness levels.
1.1 How to order
M40 A
Model Power
-
Opon 1 Others
H- - -
Opon 2
-
Opon 3
-
-R1 (1 relay)
-AO (analog output)
-RTU (Modbus RTU)
-S4 (RS-485)
-S2 (RS-232)
- (empty)
-H (85-265 Vac/dc)
-L (11/60 Vdc,
24 Vac, 48 Vac)
-NBT (no buons)
-65 (front IP65)
-G (green led)
Index
1. Panel meter M40-A. . . . . . . . . . . . . . . . . . . . . . . 2
1.1 How to order . . . . . . . . . . . . . . . . . . . . . . . . 2
1.2 Front view . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.3 Rear view . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.4 Power connecons . . . . . . . . . . . . . . . . . . . . . 3
1.5 Signal connecons - AC voltage . . . . . . . . . . . . . . 3
1.6 Signal connecons - AC current . . . . . . . . . . . . . . 3
1.7 Technical specicaons . . . . . . . . . . . . . . . . . . 4
1.8 Mechanical dimensions (mm) . . . . . . . . . . . . . . . 5
1.9 Coupling ‘AC’ or ‘AC+DC’ . . . . . . . . . . . . . . . . . . 5
1.10 How to operate the menus. . . . . . . . . . . . . . . . 6
1.11 Messages and errors . . . . . . . . . . . . . . . . . . . 6
1.12 Conguraon menu. . . . . . . . . . . . . . . . . . . . 7
1.12.1 Inial set-up . . . . . . . . . . . . . . . . . . . . . . 7
1.12.2 Field correcon . . . . . . . . . . . . . . . . . . . . 7
1.12.3 Alarms . . . . . . . . . . . . . . . . . . . . . . . . . 8
1.12.4 Display lters. . . . . . . . . . . . . . . . . . . . . . 9
1.12.5 Fast access . . . . . . . . . . . . . . . . . . . . . . .10
1.12.6 Super fast access . . . . . . . . . . . . . . . . . . .10
1.12.7 Menu ‘On Power Up’ . . . . . . . . . . . . . . . . . 10
1.12.8 Menu ‘Key LE’ . . . . . . . . . . . . . . . . . . . . .11
1.12.9 Funcon ‘Password’ . . . . . . . . . . . . . . . . . 11
1.12.10 Factory reset . . . . . . . . . . . . . . . . . . . . .11
1.12.11 Firmware version. . . . . . . . . . . . . . . . . . . 11
1.12.12 Brightness . . . . . . . . . . . . . . . . . . . . . .11
1.12.13 Access to oponal modules . . . . . . . . . . . . . 11
1.13 Full conguraon menu . . . . . . . . . . . . . . . . . 12
1.14 To access the instrument . . . . . . . . . . . . . . . . .14
1.15 Modular system . . . . . . . . . . . . . . . . . . . . . .14
1.16 Precauons on installaon . . . . . . . . . . . . . . . .15
1.17 Factory conguraon . . . . . . . . . . . . . . . . . . .15
1.18 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . .15
1.19 CE declaraon of conformity . . . . . . . . . . . . . . .15
2. Output and control modules . . . . . . . . . . . . . . . . .16
2.1 Module R1. . . . . . . . . . . . . . . . . . . . . . . . . . 16
2.2 Module AO . . . . . . . . . . . . . . . . . . . . . . . . .16
2.3 Module RTU. . . . . . . . . . . . . . . . . . . . . . . . . 17
2.4 Module S4. . . . . . . . . . . . . . . . . . . . . . . . . . 17
2.5 Module S2. . . . . . . . . . . . . . . . . . . . . . . . . . 18
2.6 Modules R2, R4, R6. . . . . . . . . . . . . . . . . . . . . 18
3. Other opons . . . . . . . . . . . . . . . . . . . . . . . . . . 20
3.1 Opon NBT . . . . . . . . . . . . . . . . . . . . . . . . .20
3.2 Opon 65 . . . . . . . . . . . . . . . . . . . . . . . . . .20
3.3 Opon G. . . . . . . . . . . . . . . . . . . . . . . . . . . 20
4. Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .21
4.1 THM benchtop housing . . . . . . . . . . . . . . . . . .21
4.2 Adapter KA96 . . . . . . . . . . . . . . . . . . . . . . . .21
4.3 Adapter DRA-M . . . . . . . . . . . . . . . . . . . . . . .21
4.4 Protector KIP . . . . . . . . . . . . . . . . . . . . . . . .21