4.
1.
1.
Parameter sets recommended for VPPM-12L-...
Tube length1) Open system Output volume in ml
0 … 2000 2000 … 10000 > 10000
0 m 3 1 2 3
1 m 3 1 2 3
3 m 3 2 3 3
³ 5 m 3 3 3 3
1) with tubing diameter 12 mm or 16 mm
Tab. 13: Parameter sets recommended for VPPM-12L-...
9 Operation
NOTICE
When switching off the VPPM.-..., first make sure that the setpoint value is set to
0, then that the supply pressure and finally the supply voltage are switched off.
9.1 Restoring VPPM-... factory setting
Restoring the factory settings deletes the current settings.
• The VPPM -... can also be reset if a security code cannot be found.
1. Press and hold the [UP], [DOWN] and [Edit] keys.
2. Switch on the operating voltage.
3. Release the [UP], [DOWN] and [Edit] keys.
ÄThe ‘ALL’ display flashes.
Use the [UP] and [DOWN] keys to select which parameters are to be reset to
the factory setting.
–‘Out’ flashes: reset all output parameters.
–‘In’ flashes: reset all input parameters.
–‘ALL’ flashes: reset all output parameters and input parameters and the
security code.
5. Press the [Edit] key to reset the selected parameter.
ÄThe VPPM-... is back in the RUN mode.
10 Maintenance
10.1 Disassembly
NOTICE
•When switching off the VPPM.-..., first make sure that the setpoint value is set
to 0, then that the supply pressure and finally the supply voltage are switched
off.
Switch off the following energy sources:
–Operating voltage
–Compressed air
2. Disconnect the connections from the device.
3. Remove the device from the mounting surface or H-rail.
10.2 Cleaning
Switch off the following energy sources to clean the outside:
–Operating voltage
–Compressed air
2. Clean the device on the outside with a soft cloth as required.
11 Malfunctions
11.1 Error display
Error indicator in
display
Cause
ER.01 Hardware error
ER.05 Supply voltage too low
ER.09 Limit value (setpoint value) undershot
ER.10 Limit value (setpoint value) overshot
ER.26 Supply voltage too high
ER.28 Temperature range exceeded in the device
Tab. 14: Error display
11.2 Fault clearance
Malfunction Possible cause Remedy
Device does not respond No supply voltage, LED [power]
off.
Check 24 V DC supply voltage
connection.
No data communication. –Check control unit.
–Check connection.
Flow rate too low Restriction of the flow cross
section by connection tech-
nology.
Use alternative connections.
Pressure rise too slow Large cylinder volume and long
tube length.
–Select another parameter
set.
–Use device with larger nom-
inal width.
Pressure constant despite
modified setpoint specification
Break in the electrical con-
necting cable.
Replace electrical connecting
cable.
Malfunction Possible cause Remedy
Pressure constant despite
modified setpoint specification
Supply pressure P1 too low. Increase supply pressure.
Manual selection of parameter
sets with the [UP] and [DOWN]
keys on the device is not pos-
sible
Voltage is applied at digital
inputs D1 and D2.
Apply 0 V DC at digital inputs
D1 and D2.
Tab. 15: Fault clearance
12 Technical data
General technical data
Design Proportional-pressure regulator
Mounting position As desired, preferably horizontal (display elements
facing upwards)
Materials
Housing Wrought aluminium alloy
Cover PAXMD6 GF50/gr-P
PA6-GB20,GF10/gr-P
Seals Nitrile rubber
Lubrication silicone-free
Weight
VPPM-6... [g] 400
VPPM-8... [g] 560
VPPM-12... [g] 2050
Tab. 16: General technical data
Operating and environmental conditions
Medium Compressed air in accordance with ISO 8573-1:2010
[7:4:4] inert gases
Information on operating
medium
Lubricated operation not possible
Degree of protection IP 65 when mounted, with tightened mounting screws,
in combination with plug socket according to accesso-
ries.
Ambient temperature [°C] 0 … 60
Temperature of medium [°C] 10 … 50
Storage temperature [°C] –10 … +70
Vibration and shock
Vibration Tested in accordance with DIN/IEC
68/EN 60068 Part 2-6; wall mounting: 0.35 mm path
at 10 … 60 Hz, 5 g acceleration at 60 … 150 Hz1)
Shock Tested in accordance with DIN/IEC
68/EN 60068 Part 2-27; wall mounting: ±30 g at 11 ms
duration; 5 shocks per direction1)
1) Information does not apply when mounting the VPPM-.../VPPX-... on bracket VAME-P1-A/-T.
Tab. 17: Operating and environmental conditions
VPPM-... 0L2H 0L6H 0L10H
Pressure ranges
Permissible input pressure P1 [MPa] 0 … 0.4 0 … 0.8 0 … 1.1
[bar] 0 … 4 0 … 8 0 … 11
[psi] 0 … 58 0 … 116 0 … 159.5
Control range (output pressure
P2)1)
[MPa] 0.002 … 0.2 0.006 … 0.6 0.01 … 1
[bar] 0.02 … 2 0.06 … 6 0.1 … 10
[psi] 2.9 … 29 8.7 … 87 1.45 … 145
Total leakage when new [l/h] < 5
Connection G 1/8, 1/8 NPT, G 1/4, 1/4 NPT, G 1/2, 1/2 NPT
Nominal width
Pressurisation [mm] 6 for VPPM-6...
8 for VPPM-8...
12 for VPPM-12...
Exhaust port [mm] 4.5 for VPPM-6...
6 for VPPM-8...
12 for VPPM-12...
1) Input pressure P1 at least 0.1 MPa (1 bar, 14.5 psi) above output pressure P2.
Tab. 18: Characteristic pneumatic values
Characteristic electrical values
Electrical connection Pin contact M12x1, 8-pin
Permissible operating voltage [V DC] 21.6 … 26.4
Permissible residual ripple max. 10%
Power rating of digital
switching output D3 (PIN 8 in
el. connection)
[mA] max. 60
Max. permissible supply cable
length and signal line length
[m] 10
Max. electrical power consumption
VPPM-6... and VPPM-8... [W] 7