DVC6200 Digital Valve Controller
i
i
Field Communicator Fast-Key Sequence and Menu Trees
Instrument Level HC, AD, PD, and ODV
Function/Variable Fast-Key
Sequence Coordinates(1)
Actuator Style 1-2-6-4 4-D
Alert Conditions 2-1 2-E
Alert Record Full Enable 1-2-3-6-2 8-F
1-2-3-7-2
Alert Record Not Empty Alert
Enable 1-2-3-6-1 9-F
1-2-3-7-1
Analog Input 3-1 2-F
Analog Input Calibration 1-3-2-2 4-E
Analog Input Range Hi 1-2-5-3-1 6-H
Analog Input Range Lo 1-2-5-3-2 6-H
Analog Input Units 1-2-5-2-3 6-G
Auto Calibration 1-3-1-1 4-E
Autocalibration in Progress Enable 1-2-4-2-2 8-H
Auxiliary Input 3-6-1 5-G
1-2-3-3-2-2 10-D
Auxiliary Terminal Alert Enable 1-2-3-3-2-2 10-D
Auxiliary Terminal Mode 1-2-3-3-2-3 10-D
1-2-5-7 5-F
Burst Command 1-2-1-4-2 5-A
Burst Enable 1-2-1-4-1 5-A
Calibration in Progress Enab 1-2-4-2-1 8-H
Calibration Location 1-2-5-9-2 6-H
Clear Record 1-2-3-6-4 8-G
1-2-3-7-4
Command 3 (Trending) Pressure 1-2-1-4-3 5-A
Control Mode Hot Key-2 1-A
1-2-1-2 4-B
Critical NVM Shutdown 1-2-3-1-3-4 12-C
Cycle Count 1-2-3-5-1-2 10-F
3-6-5 4-H
Cycle Count Alert Enable 1-2-3-5-1-1 10-F
Cycle Count Alert Point 1-2-3-5-1-3 10-F
Date 1-2-5-1-4 6-F
Dead Band (Cycle Count / Travel
Accum) 1-2-3-5-2-1 10-F
Define Custom Characteristic 1-2-2-4 4-C
Descriptor 1-2-5-1-3 6-F
Device Description Information 3-8 2-G
Device ID 3-7-2 4-H
Device Revision 3-7-5 4-H
Diagnostic Data Available Enable 1-2-4-2-4 8-H
Diagnostic in Progress Enable 1-2-4-2-3 8-H
Display Record 1-2-3-6-3 8-F
1-2-3-7-3
Drive Current Shutdown 1-2-3-1-1 8-C
Drive Signal 3-4 2-F
1-2-3-1-2-2 10-C
Drive Signal Alert Enable 1-2-3-1-2-1 10-C
Function/Variable Fast-Key
Sequence Coordinates(1)
Edit Feedback Connection 1-2-6-6 4-D
End Point Control Enable(3) 1-2-2-2-5-1 6-C
Failure Group Enable 1-2-3-6-5-1 10-G
1-2-3-7-5-1
Firmware Revision 3-7-6 4-H
Flash ROM Shutdown 1-2-3-1-3-5 12-C
Hardware Revision 3-7-7 4-I
HART Tag 1-2-5-1-1 6-F
3-7-1 4-H
HART Universal Revision 3-7-9 4-H
Input Characterization 1-2-2-3 4-C
Instrument Date and Time 1-2-4-1-2 8-G
1-2-5-8 5-F
Instrument Level 3-7-8 4-H
Instrument Mode Hot Key-1 1-A
1-2-1-1 4-B
Instrument Serial Number 1-2-5-1-6 6-F
Instrument Time Invalid Enable 1-2-4-1-1 8-G
Integral Dead Zone 1-2-4-4-4 8-I
1-2-2-1-2-1 9-A
Integral Limit 1-2-4-4-3 8-I
1-2-2-1-2-2 9-B
Integrator Saturated Hi Enable 1-2-4-4-1 8-I
Integrator Saturated Lo Enable 1-2-4-4-2 8-I
Lag Time(4) 1-2-2-5-3 6-C
Last Calibration Status 1-2-5-9-1 6-H
Lead/Lag(3) 1-2-2-5-3 6-C
Loop Current Validation Enable 1-2-3-3-3 9-E
Low Power Write Fail Enable 1-2-3-1-3-2 12-B
Manual Calibration 1-3-1-2 4-E
Manufacturer 3-7-3 4-H
1-2-6-1 4-D
Maximum Supply Pressure 1-2-5-6 5-F
Message 1-2-5-1-2 6-F
Miscellaneous Group Enable 1-2-3-6-5-3 10-G
1-2-3-7-5-3
Model 3-7-4 4-H
Multi-Drop Alert Enable 1-2-4-3-2 8-H
No Free Time Shutdown 1-2-3-1-3-6 12-C
Non-Critical NVM Alert Enable 1-2-3-1-3-3 12-B
Number of Power Ups 2-3-4 4-F
3-6-9 5-H
Offline/Failed Alert Enable 1-2-3-1-3-1 11-B
Partial Stroke Test 2-5 2-F
Partial Stroke Test Enable(3) 1-2-7-1 3-D
Partial Stroke Test Pressure
Limit(3) 1-2-3-6-1 8-F
Partial Stroke Test Start Point(3) 1-2-2-2-5-2 8-C
Continued on next page
NOTE: Italicized Fast-Key Sequence indicates fast-key sequence is applicable only for instrument level ODV.
1. Coordinates are to help locate the item on the Field Communicator Menu Tree for Instrument Level HC, AD, PD, and ODV.
2. Instrument level AD, PD, and ODV only.
3. Instrument level ODV only.
4. Instrument level HC, AD, and PD only.
5. Instrument level HC only.