manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Fluke
  6. •
  7. Test Equipment
  8. •
  9. Fluke T6-600 User manual

Fluke T6-600 User manual

HOLD
Hz
FieldSense
3
2
1
5
7
6
HOLD
200 A
CAT
1000 V
CAT600 V
4
HOLD
200A
CAT
1000 V
CAT600 V
AUTO
SELECT
T6-10 00
ELECTRICAL TESTER
5
2
7
3
1
4
6
Accessories
● HT6 Belt Holster
● TPAK Hanger
● PRV240FS
● AC285 SureGrip™ Alligator Clips
● AC220 SureGrip™ Alligator Clips
Test Lead Assembly (T5-RLS) Replace
only with Fluke double-insulated
leads (T)
TP1 Probe Set, Flat-Blade
Battery Door
Battery Door Screw
PN 4462973
PN 648128
PN 4944370
PN 1618579
Use only specified replacement parts.
Replacement Parts
Lead Replacement
Symbols
Function Range
Requires
Test Leads Resolution Accuracy [1]
Range
Model T6-600
Specifications
Model T6-1000
No
200.0 A
45 Hz to 66 Hz
100.0 kΩ
20.00 kΩ
Voltage ac
Current ac
Frequency (Hz)
Voltage ac
Voltage dc
Resistance
No
No
Yes
Yes
Yes
Yes
Yes
±(1 % + 2 counts) [3]
±(1 % + 2 counts)
±(1 % + 2 counts)
200.0 A
±(3 % + 3 counts)
45 Hz to 66 Hz [2][3]
±(3 % + 3 counts)
45 Hz to 66 Hz
±(1.5 % + 2 counts)
45 Hz to 66 Hz
0.1 A
0.1 kΩ
0.01 kΩ
[1] Accuracy: ± ( [ % of reading] + [number of least significant digits] ). Accuracy is specified for 1 year after calibration,
at 18 °C to 28 °C (64 °F to 82 °F) with relative humidity to 90 %. AC measurements are ac coupled, RMS responding.
[2] Add 3 % without an external ground connection. External ground connection required for user wearing insulated
gloves, standing on an insulated ladder, or otherwise insulated from earth ground.
[3] FieldSense is specified from 16 V to 100 % of range.
Fork Opening 17.8 mm
Calibration 1-year calibration cycle
Temperature
Operating -10 °C to +50 °C (+14 °F to +122 °F)
Storage -30 °C to +60 °C (-22 °F to +140 °F)
Altitude
Operating
Storage
Relative Humidity 0 % to 95 %, 5 °C to 30 °C (41 °F to 86 °F)
0 % to 75 %, 30 °C to 40 °C (86 °F to 104 °F)
0 % to 45 %, 40 °C to 50 °C (104 °F to 122 °F)
Battery Type and Life 2x AA (IEC LR6) 360 hr continuous, typical is 200 hr using the FieldSense function
Temperature coefficient 0.1 x (specified accuracy) / °C for <18 °C or >28 °C (<64.4 °F or >82.4 °F)
Test with fork and FieldSense ground contact.
Test with fork and ground probe.
Test with probes.
FieldSense Measurement:
Fluke voltage/current sensing technique.
Good earth ground connection.
No earth ground connection.
WARNING. RISK OF DANGER.
Consult user documentation.
Battery full charge.
Back light
Battery low. Replace.
Hazardous voltage ≥30 V.
Overview
Finger Guard
Wire Position
Display
Function Selection/On/Off
1 Wire Only
FieldSense
Ground Contact
For safe operation,
hold the Tester behind
the finger guard.
XHazardous Voltage ≥30 V
Auto Off
15 min
Test Probes/Storage Dock
Model T6-600Model T6-1000Model T6-1000
�� See “Safety Information”.
Go to www.fluke.com to register your product and find more information, or
download this Quick Reference Guide in other languages.
Consulte las “Información sobre seguridad”.
Vaya a www.fluke.com para registrar el producto y obtener más información, o
descargue esta Guía de referencia rápida en otros idiomas.
Consulte o “Informações de Segurança”. Acesse www.fluke.com.br para
registrar seu produto e obter mais informações, ou baixe este Guia de
referência rápida em outros idiomas.
T6-600/T6-1000
Electrical Tester
with FieldSense Technology
Quick Reference Guide
GuÍa de referencia rápida
Guia de referência rápida
Fork Opening 17.8 mm
PN 4897598 September 2017
© 2017 Fluke Corporation. All rights reserved.
Specifications are subject to change without notification.
»
PN 4897598 September 2017 Rev. 1, 10/17
© 2017 Fluke Corporation. All rights reserved.
Specifications are subject to change without notification.
FieldSense
FieldSense
FieldSense
1000 V
1000 V
1000 V
2000 Ω 2000 Ω
600 V
600 V
600 V
1 V
1 V
1 V
1 Hz
1 Ω
2000 m
10 000 m
PN 1618579
PN 4944370
PN 648128
PN 4462973
1.888.610.7664[email protected]
Fluke-Direct
.com
HOLD
200A
CAT
1000 V
CAT600 V
2
1
HOLD
200
A
CAT1000V
CAT
600 V
HOLD
1
2A
2B
HOLD
T6 - 6 00
ELECTRICAL TESTER
AUTO
SELECT
CAT
HOLD
T6 - 60 0
ELECTRICAL TESTER
AUTO
SELECT
CAT
CAT600 V
200A
1
2
4
3
5
CAT6 00 V
200A
=
HOLD
T6 - 6 00
ELECTRICAL TESTER
AUTO
SELECT
CAT
HOLD
T6 - 6 00
ELECTRICAL TESTER
AUTO
SELECT
CAT
HOLD
T6 - 60 0
ELECTRICAL TESTER
AUTO
SELECT
CAT
CAT600 V
200A
1
2
4
3
5
HOLD
CAT6 00 V
200A
=
HOLD
T6 - 6 00
ELECTRICAL TESTER
AUTO
SELECT
CAT
T6- 10 00
ElectricalTester
HOLD
Hz
FieldSense
/ /
HOLD
HOLD
200A
CAT
1000 V
CAT600V
HOLD
200A
CAT
1000 V
CAT600 V
1
2
4
3
5
=Hz
HOLD
HOLD
200A
CAT
1000 V
CAT600V
1
2
4
3
5
/ / /
/
/
T6- 10 00
ElectricalTester
HOLD
Hz
FieldSense
Hz Hz
Hz
HOLD
200A
CAT
1000 V
CAT600 V
=Hz
HOLD
/
1
2B
2A
HOLD
(DC)
(AC)
HOLD
200 A
CAT
1000 V
CAT600 V
HOLD
Tips: FieldSense Technology
● shows on the
display
● Display color is gray
● VAC measurement
does not show on
display
● Display color turns green
● Display shows a valid measurement >16 V
rather than dashes or 0.0
● Y shows for measurement ≥30 V
● Measurement is <16 V
● Check the wire position in the
fork opening. See the section
about wire position.
● Display color is gray
● VAC measurement
does not show on
display
Use the black probe to make the ground connection if:
● wearing gloves or insulated footwear
● standing on an insulated ladder
● additional ground contact is required for the application
W Do not hold or touch wire during ameasurement.
If you see: Solution:
FieldSense measurement looks like this when properly grounded:
Do not
overtighten
screw
Low Battery
Indicator
● Make sure that your bare hand
is firmly touching the FieldSense
Ground Contact on the battery
door.
● Check that the black probe is
properly stored in the dock.
● Check the wire position in the
fork opening. See the section
about wire position.
Display turns
green for valid
measurement.
See Tips.
Display turns
green for valid
measurement.
See Tips.
Hold hand firmly on
FieldSense
Ground Contact
Insert Test Probes
into the storage dock
Use the Ground Probe
Display turns
green for valid
measurement.
See Tips.
Display turns
green for valid
measurement.
See Tips.
Use the Ground Probe
Insert Test Probes
into the storage dock
Hold hand firmly on
FieldSense
Ground Contact
T6-600 max: 600 V CAT III
T6-1000 max: 1000 V CAT III
600 V CAT IV
45 Hz - 66 Hz
T6-600 max: 600 V rms CAT III
T6-1000 max: 1000 V rms CAT III
600 V rms CAT IV
How to Make MeasurementsHow to Make Measurements
Model T6-600
Model T6-1000
2 AA
1.888.610.7664[email protected]
Fluke-Direct
.com

Other manuals for T6-600

1

This manual suits for next models

1

Other Fluke Test Equipment manuals

Fluke 5520A Service User manual

Fluke

Fluke 5520A Service User manual

Fluke 9132 User manual

Fluke

Fluke 9132 User manual

Fluke 6270A User manual

Fluke

Fluke 6270A User manual

Fluke 7526A Use and care manual

Fluke

Fluke 7526A Use and care manual

Fluke ProcessMeter 787 User manual

Fluke

Fluke ProcessMeter 787 User manual

Fluke 718 Series Owner's manual

Fluke

Fluke 718 Series Owner's manual

Fluke CableIQ User manual

Fluke

Fluke CableIQ User manual

Fluke 709 Instruction manual

Fluke

Fluke 709 Instruction manual

Fluke 525A User manual

Fluke

Fluke 525A User manual

Fluke 5080A User manual

Fluke

Fluke 5080A User manual

Fluke AIRCHECK Instruction manual

Fluke

Fluke AIRCHECK Instruction manual

Fluke 725 Operating and safety instructions

Fluke

Fluke 725 Operating and safety instructions

Fluke ScopeMeter 192B User manual

Fluke

Fluke ScopeMeter 192B User manual

Fluke P3000 Series User manual

Fluke

Fluke P3000 Series User manual

Fluke 700G Series Instruction manual

Fluke

Fluke 700G Series Instruction manual

Fluke 820-2 User manual

Fluke

Fluke 820-2 User manual

Fluke 5500A User manual

Fluke

Fluke 5500A User manual

Fluke 9102S User manual

Fluke

Fluke 9102S User manual

Fluke 721-1601 Use and care manual

Fluke

Fluke 721-1601 Use and care manual

Fluke CableAnalyzer DSX-500 User manual

Fluke

Fluke CableAnalyzer DSX-500 User manual

Fluke i1000s User manual

Fluke

Fluke i1000s User manual

Fluke 4180 Quick start guide

Fluke

Fluke 4180 Quick start guide

Fluke 729 User manual

Fluke

Fluke 729 User manual

Fluke 9100S User manual

Fluke

Fluke 9100S User manual

Popular Test Equipment manuals by other brands

Vanguard Instruments Company SGT-600 user manual

Vanguard Instruments Company

Vanguard Instruments Company SGT-600 user manual

INNOMARK gamma quick start guide

INNOMARK

INNOMARK gamma quick start guide

Elma Instruments SAGAB Volt Stick PHASEN quick start guide

Elma Instruments

Elma Instruments SAGAB Volt Stick PHASEN quick start guide

Airblas PHD-620 manual

Airblas

Airblas PHD-620 manual

Compliance West MegaPulse 360 instruction manual

Compliance West

Compliance West MegaPulse 360 instruction manual

Elenco Electronics TPG-70 instruction manual

Elenco Electronics

Elenco Electronics TPG-70 instruction manual

Crystal XP2i Operation manual

Crystal

Crystal XP2i Operation manual

Tektronix P3010 instructions

Tektronix

Tektronix P3010 instructions

Workzone 46857-15 user guide

Workzone

Workzone 46857-15 user guide

YUSHI UM Series operating manual

YUSHI

YUSHI UM Series operating manual

Rossmax ThermoCal instruction manual

Rossmax

Rossmax ThermoCal instruction manual

Testboy TB 72 user manual

Testboy

Testboy TB 72 user manual

Teledyne Oceanscience rapidCAST user guide

Teledyne Oceanscience

Teledyne Oceanscience rapidCAST user guide

Ametek LS2.5 Series user manual

Ametek

Ametek LS2.5 Series user manual

Matatakitoyo Torque Tools ETT-15NP Operation manual

Matatakitoyo Torque Tools

Matatakitoyo Torque Tools ETT-15NP Operation manual

Tektronix Keithley 8020-STC manual

Tektronix

Tektronix Keithley 8020-STC manual

FLIR Extech Instruments 382252 manual

FLIR

FLIR Extech Instruments 382252 manual

MOB MO7161 user manual

MOB

MOB MO7161 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.