formlabs Form Wash L User manual

Manual Form Wash L


Installation and Usage Instructions
Form Wash L
Large-format Desktop Stereolithography
(SLA) Print Cleaner
Original English instructions
Read this manual carefully and keep it for future reference.
November 2021
REV 01
© Formlabs

1 Table of Contents
1Preface ..................................................................6
1.1 Read and retain instructions ................................................6
1.2 Obtaining documentation and information ...................................6
2Introduction ..............................................................8
2.1 Intended use..............................................................8
2.2 Technical specifications ....................................................9
2.3 Product components. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
2.4 User interface.............................................................11
3Safety...................................................................12
3.1 Component and subsystem safety .........................................13
3.2 Personal protective equipment (PPE) .......................................14
3.3 Specification of tools to be used ...........................................14
3.4 Sensitive components ....................................................15
3.5 Emergency and exceptional situations ......................................15
4Preparation and setup....................................................17
4.1 Location and environs ....................................................17
4.2 Power and networking ....................................................17
4.3 Unboxing the machine ....................................................17
4.4 Accessing the serial name. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
4.5 Installing the machine.....................................................18
4.6 Setting up a network connection ...........................................19
4.7 Updating firmware .......................................................20
4.8 Transporting the machine ................................................ 20
5Usage.................................................................. 23
5.1 Operational environment................................................. 23
5.2 Washing printed parts.................................................... 23
5.3 Considerations for specific geometries .................................... 26
5.4 Time settings ............................................................27
5.5 Managing the machine....................................................27
6Maintenance ...........................................................29
6.1 Tools and supplies....................................................... 29

6.2 Inspection and maintenance.............................................. 30
6.3 Tasks between uses ..................................................... 30
6.4 Periodic maintenance.................................................... 30
6.5 Intermittent maintenance ................................................. 32
7Troubleshooting ........................................................ 34
7.1 Collecting diagnostic logs .................................................34
7.2 Performing a factory reset .................................................34
7.3 Cleaning after a chemical spill .............................................34
7.4 Troubleshooting errors or abnormal activity ................................ 35
8Disassembly and repair.................................................. 38
8.1 Tasks................................................................... 38
9Recycling and disposal .................................................. 39
9.1 Disposal of resin ........................................................ 39
9.2 Recycling of resin ....................................................... 39
9.3 Disposal of solvent ...................................................... 39
9.4 Recycling of solvent ..................................................... 40
9.5 Disposal of electronic components........................................ 40
9.6 Disposal of packaging waste ............................................. 40
10 Index....................................................................41
11 Glossary. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
12 Product compliance ..................................................... 43


Disclaimer | 5
Read and understand this manual and its safety instructions before using the Form
Wash L. Failure to do so can result in serious injury or death.
DISCLAIMER
Formlabs has made every eort to make these instructions as clear, complete, and correct
as possible. The information provided in this documentation contains general descriptions
and/or technical characteristics of the performance of the products contained herein. This
documentation is not intended as a substitute for and is not to be used for determining
suitability or reliability of these products for specific user applications. It is the duty of any
such user or integrator to perform the appropriate and complete risk analysis, evaluation, and
testing of the products with respect to the relevant specific application or use thereof. Neither
Formlabs nor any of its aliates or subsidiaries shall be responsible or liable for misuse of the
information that is contained herein. Notify us if you have any suggestions for improvements
or amendments or have found errors in this publication.
Copyright © 2021 by Formlabs. All rights reserved.
support.formlabs.com
TRADEMARKS
All product names, logos, and brands are property of their respective owners. All company,
product, and service names used in this manual are for identification purposes only. Use of
these names, logos, or brands does not imply endorsement.
DOCUMENT REVISIONS
Date Version Document changes
Nov 2021 REV 01 Initial publication
WARNING

6
1 Preface
Congratulations on purchasing the Form Wash L. On behalf of the Formlabs team, we thank
you for your purchase.
The Form Wash L is a large-format stereolithography (SLA) print cleaner. The Form Wash L
removes uncured resin from the surface of printed parts by simultaneously soaking and moving
them in a solvent. The Form Wash L uses either isopropyl alcohol (IPA), tripropylene glycol
monomethyl ether (TPM), or water.
This manual explains how to set up, use, and properly maintain the Form Wash L, as well as
provides design guidance for optimizing print results.
The manual is intended for anyone who is installing, operating, maintaining, or otherwise
interacting with the Form Wash L. Supervise young or inexperienced users to ensure enjoyable
and safe operation.
1.1 Read and retain instructions
Read and understand this manual and its safety instructions before using the Form Wash L.
Failure to do so can result in serious injury or death. Keep all safety information and instructions
for future reference and provide them to subsequent users of the product.
Follow all instructions to avoid fire, explosions, electric shocks, or other hazards that may result
in damage to property and/or severe or fatal injuries.
The Form Wash L shall only be used by persons who have fully read and understand the
contents of this manual. Ensure that each person who uses the Form Wash L has read these
warnings and instructions and follows them. Formlabs is not liable for cases of material damage
or personal injury caused by incorrect handling or non-compliance with the safety instructions.
In such cases, the warranty will be voided.
1.2 Obtaining documentation and information
Visit formlabs.com to:
•
Access your Formlabs store (formlabs.com/store) and Dashboard accounts (formlabs.
com/dashboard).
• Find authorized resellers in your region (formlabs.com/company/partners).
•
Access the Terms of Service (formlabs.com/terms-of-service) and the Privacy Policy
(formlabs.com/privacy-policy).
Visit support.formlabs.com to:
• Access the latest version of all Formlabs product documentation.
•
Contact Formlabs Support to request documentation, manuals, repair guides, and
technical information.
• Submit any comments or feedback regarding what is good and what can be improved.
Formlabs values comments from its users.
• Request additional training.
1.2.1 Support and service
Retain a record of the original purchase to request warranty services. Service options depend
on the status of the specific product’s warranty. Include the serial name of the product when
contacting Formlabs Support or a certified service provider for product support. For products

Preface | 7
purchased from authorized resellers, contact the original service provider for assistance before
contacting Formlabs Support.
Instead of a serial number, Formlabs products have a serial name, which is a unique identifier
to track the history of manufacturing, sales, and repair, and to distinguish usage when
connected to a network. The serial name is on the back panel of the machine in the format
AdjectiveAnimal.
Service providers of Formlabs products also provide support and service. To the extent that
Formlabs or a certified service provider oers other or extended warranties, the terms of the
separate oer may apply.
For any support or service requests, including product information, technical assistance, or
assistance with instructions, contact Formlabs Support:
support.formlabs.com USA
Formlabs, Inc.
35 Medford St.
Somerville, MA, USA, 02143
Germany
Formlabs GmbH
Nalepastrasse 18
12459 Berlin, Germany
1.2.2 Warranty
This product is protected under warranty. Formlabs oers a warranty for all Formlabs branded
hardware. Unless otherwise expressly stated, the Terms of Service, including the Warranty,
constitute the entire agreement between you and Formlabs with respect to the Service and
any product you purchase from Formlabs and supersedes all prior or contemporaneous
communications, proposals, and agreements, whether electronic, oral, or written, between
you and Formlabs.
Read the warranty for more details on the Formlabs warranty for your region:
US formlabs.com/support/terms-of-service
EU (EN) formlabs.com/eu/terms-of-service
EU (DE) formlabs.com/de/support/terms-of-service/eu
EU (FR) formlabs.com/fr/support/terms-of-service/eu
EU (ES) formlabs.com/es/terms-of-service/eu
EU (IT) formlabs.com/it/terms-of-service/eu

8
2 Introduction
2.1 Intended use
The Form Wash L automatically cleans uncured liquid resin from 3D printed parts. The
final performance characteristics of cured photopolymer resin may vary according to your
compliance with the instructions for use, application, operating conditions, material combined
with, end use, or other factors.
In some cases, the additive manufacturing process may inherently result in variable
performance characteristics between manufacturing runs or within a specific part.
Such variances may not be apparent and may result in unexpected defects in
additively fabricated parts.
You shall independently verify the suitability of additive manufacturing,
stereolithography (SLA), the Form Wash L, and any specific designs or materials
employed for the application and intended purpose before use. In no event shall
Formlabs be liable for any loss, death, or bodily injury that you suer, or that you
cause to any third party, in connection with your use of Formlabs products. To the
fullest extent legally permitted Formlabs EXPRESSLY DISCLAIMS ANY IMPLIED OR
EXPLICIT WARRANTY OF FITNESS for a particular usage, the particular nature and
circumstances of said usage being unforeseen and unforeseeable to Formlabs.
Formlabs is not a manufacturer of medical devices. Formlabs provides tools and
materials that may be used in many applications, but makes no claims as to the safety
or eectiveness of any specific devices made using Formlabs products. Certain
Formlabs products, such as those commonly known in the industry as “biocompatible”
materials, have been engineered to comply with relevant industry standards. The
specific standards and most relevant technical specifications may be identified
within the technical data sheets and have been tested according to relevant testing
protocols for those standards and specifications. Biocompatible materials are a
speciality product, developed for use by medical professionals, and should be used in
accordance with the instructions for use.
Do not modify. The Form Wash L is intended for use as-is. Modifying the machine
without explicit approval and directions from Formlabs or a certified service provider will
void your warranty, and could potentially ruin the machine and cause you bodily harm.
NOTICE
WARNING
WARNING
WARNING

Introduction | 9
2.2 Technical specifications
Visit formlabs.com for additional information on technical specifications.
Parameter Unit
Unit Form Wash L
Installation surface Floor-standing unit
Minimum dimensions for convenient
access
(W × D × H)
100 × 120 × 120 cm
40× 48 × 48 in
Product dimensions (W × D × H) 78 × 46 × 67 cm
30.7 × 18.1 × 26.4 in
Product weight 56.7 kg (without solvent)
125 lb (without solvent)
Wash bucket dimensions (W × D × H) 54 × 28 × 41 cm
21.3 × 11.0 × 16.1 in
Wash bucket capacity 43 L
11.4 US gal
42 L (11.1 US gal) minimum to reach build platform
12 L (3.2 US gal) minimum to submerge solvent monitor
Maximum part size (W × D × H) 33.5 × 20 × 30 cm
13.2 × 7.9 × 11.8 in
Compatible solvents Isopropyl alcohol (IPA)
Tripropylene glycol monomethyl ether (TPM)
Water
Operating environment 18–28 ºC
64–82 ºF
Power requirements Input (NA): 100–120 VAC, 50–60 Hz, 1 A max
Input (EU): 220–240 VAC, 50–60 Hz, 1 A max
Connectivity Wi-Fi: 2.4 GHz
Ethernet: 100 Mbit
USB: 2.0
Wi-Fi connectivity Protocol: IEEE 802.11 b/g/n
Frequency: 2.4 GHz
Supported security: WPA/WPA2
Ethernet connectivity RJ-45 Ethernet (10BASE-T/100BASE-TX) LAN port
Connect with a shielded Ethernet cable (not included):
minimum Cat5, or Cat5e or Cat6.
USB connectivity USB (rev 2.0) B port with a USB A-B cable
Sound emission Does not exceed 79.5 dB(A).
Unit control Interactive touchscreen
Alerts Touchscreen alerts

10
2.3 Product components
For detailed guidance and visual assistance, visit support.formlabs.com.
2.3.1 Form Wash L
Platform mount: Holds the build platform when washing parts on the platform.
Basket: Removable container holds parts to wash without the build platform.
Basket mount: A single hook secures the basket to raise and lower.
Outer lid: Limits solvent evaporation. Keep the lid closed when not in use.
Inner lid: A hinged, secondary lid opens and closes to contain solvent while allowing parts
to be lowered or raised from the bucket.
Wash bucket: Removable container holds a maximum of 43 L (11.4 US gal) of solvent.
Arotating impeller at the bottom circulates the solvent.
Solvent monitor: A sensor measures the amount of resin dissolved in the solvent, allowing
the Form Wash L to determine when the solvent needs to be replaced.
Touchscreen: The LCD capacitive touch user interface displays wash cycle information,
settings, and error messages.
Platform mount adapter: An adapter that can be placed on the platform mount so that
two Form 3 Build Platforms can be washed at the same time.
Solvent: Not included. Dissolves liquid resin from printed parts’ surfaces.
1
2
3
4
5
6
7
8
9
10
1
3
4
2
10
85
7
6
9

Introduction | 11
2.3.2 Additional package components
Power cable: Provides power to the Form Wash L.
Wi-Fi antenna: Allows the machine to connect to a network via Wi-Fi.
Non-reactive nitrile gloves: Wear gloves when handling liquid resin, resin-coated surfaces,
or solvent. Wash skin with plenty of soap and water
Rinse bottle: Remove resin trapped in cavities and internal channels of prints. Use clean
solvent. Formlabs recommends isopropyl alcohol.
Flush cutters: Snip to separate prints from their supports. Cut with the flat side on the
prints’ surface for minimal support marks.
Scraper: Remove prints from the build platform. Do not use the scraper to clean the resin
tank interior.
Removal tool: Pry under the raft to remove prints from the build platform. Do not use the
removal tool to clean the resin tank interior.
Electric siphon pump: A battery-powered siphon pump for moving solvent into and out
of the wash bucket. The pump has a dedicated storage slot underneath the wash bucket.
2.4 User interface
For detailed guidance and visual assistance, visit support.formlabs.com.
The Form Wash L display is a touchscreen interface. The touchscreen displays wash information
(wash time and selected material), settings, and error messages. The touchscreen serves as
the user interface for the machine.
The home screen displays the current solvent, saturation rate, wash type and time, and
serial name.
The following screens and options are accessible via the home screen on the Form Wash
L display:
Settings • Connectivity
• Update Firmware
• Washing Guidelines
• Connect to Dashboard
• Onboarding
• Machine Sound Volume
• Tilt Mode
• Reboot
Solvent • Current Solvent
• Saturation Rate
• Number of Washes
• Replace Solvent
Select Wash Solvent • IPA
• TPM
• Custom
Wash Preset • Quick Wash
• 5 min
• Default Wash
• 10 min
• Long Wash
• 20 min
• Custom
• Guidelines
Start • Start a wash cycle.
1
2
3
4
5
6
7
8
1
234
5
67
8

12
3 Safety
Read and understand this manual and its safety instructions before using the Form
Wash L. Failure to do so can result in serious injury or death.
Supervise young or inexperienced users to ensure enjoyable and safe operation.
These instructions contain warnings and safety information, as explained below:
DANGER indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury.
WARNING indicates a hazard with a medium level of risk which, if not avoided, could result in death or
serious injury.
CAUTION indicates a hazard with a low level of risk which, if not avoided, could result in minor or
moderate injury.
NOTICE indicates information considered important, but not hazard-related.
DANGER: Isopropyl alcohol is a flammable chemical.
ENVIRONMENTAL HAZARD: Uncured photopolymer resin is classified as hazardous to aquatic life.
CAUTION: w present crushing and tangling hazards.
CAUTION: Take care to avoid injury from sharp elements.
MANDATORY ACTION: Refer to instruction manual/booklet.
MANDATORY ACTION: Grounding required.
MANDATORY ACTION: Disconnect before carrying out maintenance or repair.
MANDATORY ACTION: Wear eye protection.
MANDATORY ACTION: Wear thermal-insulating silicone gloves when handling hot build chambers.
WARNING
DANGER
WARNING
CAUTION
NOTICE

Safety | 13
3.1 Component and subsystem safety
3.1.1 General
The Form Wash L is a professional appliance that includes electronic components. As with
any such appliance:
• Do not operate the device with a damaged cord or plug.
• Ensure reliable grounding before connecting the device to power.
• Always disconnect power before cleaning.
• Only use well-maintained equipment.
• Operate on a clear and level surface.
Always remove solvent from the wash bucket before removing the wash bucket or
storing or transporting the Form Wash L.
•
Use the included electric siphon pump to avoid overfilling or spilling solvent. For more
information about using the siphon pump, visit support.formlabs.com.
3.1.2 Resin
Resin and solvents may cause skin irritation or an allergic skin reaction. Wear
gloves when handling liquid resin, liquid solvent, or resin-coated surfaces. Wash
skin with plenty of soap and water.
Consult the safety data sheet (SDS) as the primary source of information to
understand safety and handling of Formlabs resins. Respect Formlabs resin like any
household chemical. Follow standard chemical safety procedures and Formlabs resin
handling instructions. In general, Formlabs resin is not approved for use with food,
drink, or medical applications on the human body. Refer to the safety data sheet (SDS)
for each specific resin as well as support.formlabs.com for more detail.
3.1.3 Radio interference
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to CFR Title 47, Part 15 of FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause harmful interference to
radio communications. Operation of this equipment in a residential area is likely to cause harmful
interference, in which case the user will be required to correct the interference at their own expense.
Changes or modifications to this product not authorized by Formlabs could void the electromagnetic
compatibility (EMC) and wireless compliance and negate your authority to operate the product.
This product has demonstrated EMC compliance under conditions that included the use
of compliant peripheral devices and shielded cables between system components. It is
important that you use compliant peripheral devices and shielded cables between system
components to reduce the possibility of causing interference to radios, televisions, and other
electronic devices.
NOTICE
WARNING
NOTICE

14
3.1.4 Isopropyl alcohol (IPA)
Isopropyl alcohol is a flammable chemical. Keep away from ignition sources,
including open flames, sparks or concentrated sources of heat. Allow any printed
part cleaned with isopropyl alcohol to dry completely before post-curing.
Formlabs does not manufacture isopropyl alcohol. Consult the chemical manufacturer
or supplier for detailed safety information. Carefully follow the safety instructions
provided with the isopropyl alcohol that you purchase. Isopropyl alcohol can be
flammable, even explosive, and should be kept away from heat, fire, or sparks. Any
containers holding isopropyl alcohol should be kept closed or covered when not in
use. We also recommend that you wear protective gloves and have good ventilation
when working with isopropyl alcohol.
3.1.5 Tripropylene glycol monomethyl ether (TPM)
Formlabs does not manufacture tripropylene glycol monomethyl ether. Consult the
chemical manufacturer or supplier for detailed safety information. Carefully follow
the safety instructions provided with the tripropylene glycol monomethyl ether you
purchase. We also recommend that you wear protective gloves when working with
tripropylene glycol monomethyl ether.
3.2 Personal protective equipment (PPE)
Safe operation of the Form Wash L can be achieved by using the following equipment:
• Non-reactive nitrile gloves
• Safety glasses
Resin and solvents may cause skin irritation or an allergic skin reaction. Wear
gloves when handling liquid resin, liquid solvent, or resin-coated surfaces. Wash
skin with plenty of soap and water.
Some methods of support removal may cause small pieces of supports to
break away. Beware of flying debris. Wear eye protection and gloves to
protect the skin and eyes.
3.3 Specification of tools to be used
The Form Wash L shall only be used with supplied accessories and additional tools
recommended by Formlabs or a certified service provider. Third-party accessories and
materials may cause damage. Refer to sections 3.2 Personal protective equipment (PPE)
and 6.1 Tools and supplies for more information.
Purchase additional supplies:
DANGER
NOTICE
NOTICE
WARNING
CAUTION

Safety | 15
• Apron
• General purpose cleaner (e.g., glass cleaner)
• Isopropyl alcohol (IPA), 90% or higher, and/or tripropylene glycol monomethyl ether (TPM)
• Low-fiber paper towels
• Non-abrasive microfiber cloth
• Non-reactive nitrile gloves
• Safety glasses
• Shoe covers
3.4 Sensitive components
The Form Wash L has multiple components that are vulnerable to permanent damage if not
periodically inspected and properly maintained. Using any tools, cleaning agents, or methods
not mentioned in this manual may result in permanent damage to these components.
• Wash bucket and impellers: Removable container holds a maximum of 43 L (11.4 US gal)
of solvent. A rotating impeller at the bottom circulates the solvent.
•
Solvent monitor: A sensor measures the amount of resin dissolved in the solvent, allowing
the Form Wash L to determine when the solvent needs to be replaced.
Refer to section 6.2 for more information.
3.5 Emergency and exceptional situations
Formlabs has made every eort to provide updated safety data sheets (SDS) for every resin
product, in accordance with the latest government guidelines. Always consult the safety data
sheet (SDS) as the primary source of information to understand safety and handling of Formlabs
materials and required accessories. Visit formlabs.com/sds to download safety data sheets
for Formlabs materials.
3.5.1 Fire
Do not use water to extinguish an electrical fire. Dousing an electrical fire with water
increases the risk of electrocution, and may cause the fire to spread by allowing
electricity to conduct across additional flammable surfaces.
If a localized fire develops either inside or outside of the machine, immediately take the
following actions.
If the fire is inside the device:
1. Immediately disconnect the machine from its power source.
2. If the outer lid is open, close it if possible.
° If the fork is up and/or a part inside the Form Wash L is on fire, do not close the outer lid.
Place a fire blanket over the unit.
3. Use an ABC fire extinguisher to cover the aected area generously.
If the fire is too large to control:
1. Immediately leave the area and close the door of the room behind you.
2. Evacuate the building according to your organization’s emergency protocols.
3. Call emergency services once you have reached a safe distance from the fire.
3.5.2 Isopropyl alcohol (IPA)
DANGER

16
When handling isopropyl alcohol, always consult the safety data sheet (SDS)
from the isopropyl alcohol supplier as the primary source of information. Handle
isopropyl alcohol with gloves in a well-ventilated area. Keep away from heat,
sparks, and open flame. Isopropyl alcohol evaporates rapidly, so keep the wash
bucket and bottles closed whenever possible.
3.5.3 Resin
Never ingest resin in liquid or solid form. If swallowed, immediately call a poison
center or medical professional. Contact Chemtrec at +1 800 424 9300 for global 24-
hour emergency assistance.
Promptly clean and inspect the device after a resin spill to minimize any cosmetic or
functional damage to the machine. If you have experienced an accidental resin spill,
document the problem with photos and clean the device as best as possible. Contact
Formlabs Support or a certified service provider as soon as possible.
3.5.4 Chemical spills
Prepare for a possible chemical spill of flammable materials, such as isopropyl alcohol.
Your spill response procedure should contain the following:
• A listing of personal protective equipment (PPE), safety equipment, and cleanup materials
required for spill cleanup and an explanation of their proper use.
• Appropriate evacuation zones and procedures.
• Availability of fire suppression equipment.
• Disposal of containers for spill cleanup materials.
• The first aid procedures that might be required.
DANGER
WARNING
NOTICE

Preparation and setup | 17
4 Preparation and setup
4.1 Location and environs
Prepare a space to install and operate the Form Wash L and house the necessary accessories
and consumables.
To prepare the workspace:
• Ensure that the workspace meets the following requirements:
° Dry, indoor location
° Maximum altitude of 2000 m (6561.7 ft)
° Low ambient humidity
° Mains supply voltage fluctuations ≤ 10%
° Pollution degree of intended environment: 2
•
Operate the device in a well-ventilated room (≥ 3 air exchanges per hour) with a temperature
of 18–28 °C (64–82 °F).
•
Due to flammable vapors, place the device at least 0.9 m (3 ft) from other electrical equipment.
• Installation should include appropriate signage (“No Smoking,” etc.) to indicate that open
flames must be kept away from the device.
• Position the device so that it is easy to operate the power switch of the unit.
• Dedicate a power outlet and circuit to the device capable of delivering 1 A of current.
4.2 Power and networking
For detailed guidance and visual assistance, visit support.formlabs.com.
The Form Wash L requires reliable grounding. The power supply used with the
device must be grounded. Do not use an inadequately-rated power cable with the
Form Wash L.
For remotely monitoring the device, ensure it maintains a constant connection to a secured
network. Refer to section 4.6 Setting up a network connection for more information.
4.3 Unboxing the machine
For detailed guidance and visual assistance, visit support.formlabs.com.
Prior to unboxing, ensure that the suitable workspace has been prepared according to section
4.1 Location and environs.
4.3.1 Receiving
Shipping dimensions Shipping weight Product dimensions Product weight
96.2 × 59.7 × 82.7 cm
37.9 × 23.5 × 32.6 in
64.7 kg
142.6 lb
78 × 46 × 67 cm
30.7 × 18.1 × 26.4 in
56.7 kg
125 lb
4.3.2 Unboxing
The custom packaging the Form Wash L arrives in is specially designed to protect the machine
during shipping. During unboxing, inspect the product for any damage or missing items. In the
case of damage or missing items, contact Formlabs Support or a certified service provider.
NOTICE

18
To unbox the machine:
1. Position the packaging near the designated location, leaving enough room for two people
to comfortably maneuver throughout the area. Stand the packaging upright to ensure it
is level.
2. Lift the outer cardboard box o of the lower carrier tray.
3. Open the lid of the machine and remove the accessories box.
4. Remove the foam inserts from the top of the machine.
5. Use the provided handles on the carrying slings to lift the machine out of its carrier tray.
6. Carefully move the machine onto its workspace.
If you need to readjust the Form Wash L, use the carrying slings to pick the machine
back up. Do not pick up the Form Wash L without the carrying slings.
7. Tilt each side of the machine up slightly to remove the carrying slings.
Keep the original packaging for transportation or shipping.
4.4 Accessing the serial name
The serial name is a unique identifier used to track the history of manufacturing, sales, and
repair. The serial name for the Form Wash L is located on the back of the unit in the format
AdjectiveAnimal and is accessible via the touchscreen.
To access the serial name on the touchscreen:
1. If you are currently viewing a submenu on the touchscreen, tap the < arrow until you return
to the home screen. The home screen lists your current wash settings and the device status.
2. The serial name is listed in the top-left corner.
4.5 Installing the machine
For detailed guidance and visual assistance, visit support.formlabs.com.
After selecting a location, connect the device to a power source and install the Wi-Fi antenna
before turning on the device.
4.5.1 Installing the Wi-Fi antenna
Install the Wi-Fi antenna to connect the machine to a wireless network.
To install the Wi-Fi antenna, screw the Wi-Fi antenna onto the jack on the back of the unit.
4.5.2 Connecting the cables
Plug the included power cable into the power port on the back of the unit and connect the
power cable to a circuit.
For Ethernet, connect the machine to your LAN. Refer to section 4.6 Setting up a network
connection for more information.
4.5.3 Filling the wash bucket with solvent
Fill the Form Wash L with your choice of compatible solvent before use.
To fill the wash bucket:
1. Open the outer lid.
2. Pour or siphon solvent into the wash bucket to fill to a level between the minimum and
maximum fill lines.
CAUTION
Table of contents
Other formlabs 3D Printer manuals

formlabs
formlabs IBT Flex Resin User manual

formlabs
formlabs Fuse 1 User manual

formlabs
formlabs FORM 1 User manual

formlabs
formlabs Form Wash User manual

formlabs
formlabs Form Cure User manual

formlabs
formlabs Form 3 User manual

formlabs
formlabs Form 3BL User manual

formlabs
formlabs Form 2 User manual

formlabs
formlabs Form 3 User manual

formlabs
formlabs Form 3 User manual